Jan M Ruijter

Dr. Jan M Ruijter


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2021 in Life
Verified
Journal Article
Open access
PDF file
ARAdrián Ruiz-Villalba
Adrián Ruiz-Villalba
JRJan M Ruijter
Jan M Ruijter
Maurice J B van den HoffMaurice J B van den Hoff
Maurice J B van den Hoff
In the analysis of quantitative PCR (qPCR) data, the quantification cycle (Cq) indicates the position of the amplification curve with respect to the cycle axis. Because Cq is directly related to the starting concentration of the target, and the difference in Cq values is related to the starting concentration ratio, the only results of qPCR analysis reported are often Cq, ΔCq or ΔΔCq values. However, reporting of Cq values ignores the fact that Cq values may differ between runs and machines, and, therefore, cannot be compared between laboratories. Moreover, Cq values are highly dependent on the PCR efficiency, which differs between assays and may differ between samples. Interpreting reported Cq values, assuming a 100% efficient PCR, may lead to assumed gene expression ratios that are 100-fold off. This review describes how differences in quantification threshold setting, PCR efficiency, starting material, PCR artefacts, pipetting errors and sampling variation are at the origin of differences and variability in Cq values and discusses the limits to the interpretation of observed Cq values. These issues can be avoided by calculating efficiency-corrected starting concentrations per reaction. The reporting of gene expression ratios and fold difference between treatments can then easily be based on these starting concentrations.

Verified
Journal Article
Open access
PDF file
JRJan M Ruijter
Jan M Ruijter
Maurice J B van den HoffMaurice J B van den Hoff
Maurice J B van den Hoff
Quantitative Polymerase Chain Reaction (qPCR) is a very sensitive method to determine small amounts of DNA or RNA in experimental, environmental, veterinary, forensic and clinical samples. Despite efforts from the qPCR community to address qPCR variability by recommending standardization of reporting of all steps of a qPCR experiment, most reported qPCR results are still grossly biased. The first part of this paper describes two decades of efforts to remedy this situation by promoting so-called efficiency-corrected qPCR data analysis. Although such analysis leads to less variable qPCR results, the outcome, fluorescence at cycle zero, is difficult to grasp. In the second part, we outline how qPCR analyses can result in Ncopy, the number of copies of the target at the start of the reaction. A newly developed theoretical approach determines Ncopy using the characteristics of the amplification curve and the known concentrations of all reaction components. By including these reaction-mix characteristics in the analysis, this Ncopy is assay-, machine- and laboratory-independent and thus allows direct worldwide comparisons. Moreover, Ncopy provides a very intuitive and easy-to-interpret absolute quantitative result.

Verified
Journal Article
Open access
PDF file
SBStephen Bustin
Stephen Bustin
Maurice J B van den HoffMaurice J B van den Hoff
Maurice J B van den Hoff
Michael W. PfafflMichael W. Pfaffl
Michael W. Pfaffl
MKMikael Kubista
Mikael Kubista
JRJan M Ruijter
Jan M Ruijter
Amplification efficiency is one of the key parameters in quantitative real-time PCR, as it directly influences the accuracy of both absolute and relative quantification. Amplification efficiency, the fold increase per cycle, is affected by oligonucleotide design, reaction chemistry, sample and template properties, and instrument performance. Consequently, it differs between samples, assays and experimental runs. Although methods for estimating the amplification efficiency have been available for more than two decades, most published qPCR studies continue to assume equal and ideal efficiency across assays. This simplifying assumption introduces efficiency- and expression-dependent error into relative expression and fold-change analyses, contributing to the poor reproducibility observed in many PCR-based studies. This review examines the role of the amplification efficiency in qPCR quantification; the consequences of ignoring, assuming or misapplying efficiency; and the practical implications for data interpretation. The review also considers the development of efficiency estimation models and their implications for contemporary analytical approaches, including emerging data-driven methods for amplification curve analyses.

31 October 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
JRJan M Ruijter
Jan M Ruijter
Maurice J B van den HoffMaurice J B van den Hoff
Maurice J B van den Hoff
Quantitative Polymerase Chain Reaction (qPCR) is a very sensitive method to determine small amounts of DNA or RNA in experimental, environmental, veterinary, forensic and clinical samples. Despite efforts from the qPCR community to address qPCR variability by recommending standardization of reporting of all steps of a qPCR experiment, most reported qPCR results are still grossly biased. The first part of this paper describes two decades of efforts to remedy this situation by promoting so-called efficiency-corrected qPCR data analysis. Although such analysis leads to less variable qPCR results, the outcome, fluorescence at cycle zero, is difficult to grasp. In the second part, we outline how qPCR analysis can result in Ncopy, the number of copies of the target at the start of the reaction. This newly developed theoretical approach determines Ncopy using the characteristics of the amplification curve and the known concentrations of all reaction components. By including these reaction-mix characteristics in the analysis, this Ncopy is assay, machine and laboratory independent and thus allows direct worldwide comparisons. Moreover, Ncopy provides a very intuitive and easy to interpret absolute quantitative result.