Marko Popović

Marko Popović

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
MDM Drdlová
M Drdlová
MPMarko Popović
Marko Popović
MŠM Šebík
M Šebík
The response of cement-bonded wood-chip (CBWC) material under static and dynamic load was investigated both experimentally and numerically. This investigation is a part of complex development of safety road barrier with integrated noise protecting wall based on the wood-chip boards. Three types of materials with different amount of the binder were investigated in two moisture content states in order to obtain a comprehensive overview of the properties and behavior of the material at several types of loading, necessary for future design of the safety barrier. Real quasi-static (compressive, tensile and flexural strength) and dynamic experiments (IZOD test and Newton Cradle drop test) were carried out. The research revealed strong dependence of the mechanical properties on the moisture content in the material, with different trend – toughness showed ascending trend with increasing moisture content, whereas compressive, flexural and tensile strength were lower when the CBWS material was soaked. The results of the tests were used as inputs for creating and subsequently verifying the numerical material model of cement-bonded wood-chip material. The material model was used in numerical simulations of crash test of mobile noise protecting wall according to the ČSN EN 1317 standard.

30 November 2025 in Buildings
Verified
Journal Article
Open access
PDF file
MMMiloš Branislav Marković
Miloš Branislav Marković
MPMarko Popović
Marko Popović
DNDragan Nikolić
Dragan Nikolić
Damir VarevacDamir Varevac
Damir Varevac
Aleksandar Radoje SavićAleksandar Radoje Savić
Aleksandar Radoje Savić
This study examines the feasibility of incorporating cathode-ray tube (CRT) panel glass as a partial replacement of natural aggregate in concrete, aiming to promote sustainable material utilization without compromising structural performance. Nine mixtures were prepared using three cement types—Normal 42.5 N, PC 50M(S-V-L) 42.5 N; Profi 42.5 R, PC 20M(S-L) 42.5 R; and Cement without additions, CEM I 42.5 R—and three CRT contents (0%, 5%, and 10%). A comprehensive experimental program was conducted, including tests on natural aggregates, mortars, and concrete in both fresh and hardened states, as well as flexural testing of reinforced concrete beams, supported by ground-penetrating radar (GPR) and digital image correlation (DIC) measurements. The results revealed that replacing up to 5% of natural aggregate with CRT glass had negligible effects on workability and density while slightly improving compressive and flexural strength. At 10% replacement, a minor reduction in strength and ductility was observed. Durability-related parameters, such as water absorption and carbonation depth, increased slightly but remained within acceptable limits. Flexural tests confirmed that beams with 5% CRT content exhibited comparable load capacity and crack propagation to reference beams. This study represents the first combined application of Digital Image Correlation (DIC) and Ground-Penetrating Radar (GPR) in evaluating reinforced concrete beams with CRT-modified concrete across different cement types. The results showed that incorporating 5% CRT glass increased flexural tensile strength by up to 15% compared with the control mix, confirming both the structural feasibility and sustainability of such composites. Overall, the findings indicate that CRT panel glass can be effectively utilized up to a 5% replacement level, offering both environmental and structural advantages for sustainable concrete production. Based on the experimental results, a replacement level of up to 5% CRT glass is recommended for structural concrete applications under the tested conditions, where CRT particles replaced the 4–8 mm medium aggregate fraction, as it ensures a balance between strength, ductility, and durability.

1 January 2025
Verified
Conference Paper
Closed access
KKKsenija Kavarić
Ksenija Kavarić
MPMarko Popović
Marko Popović
Aleksandar Radoje SavićAleksandar Radoje Savić
Aleksandar Radoje Savić
SJSanja Jocković
Sanja Jocković
MRMilena Raković
Milena Raković
Jet grouting is a well-established and versatile ground improvement technique widely used to enhance the mechanical performance of weak or heterogeneous soils. It has proven effective across diverse soil conditions, motivating further experimental and parametric characterization. While sustainability goals have encouraged the use of eco-friendly additives, cement-based mixtures remain predominant due to their adaptability and reliable performance. Despite its widespread application, the mechanical behavior and failure mechanisms of in-situ jet grout columns have received limited experimental investigation, especially under uniaxial loading. This study explores the potential of Digital Image Correlation (DIC) as an advanced, non-contact optical technique for measurement of full-field displacements and strains on the surface of an object and fracture behavior during mechanical testing. Although DIC is more or less regularly used for concrete, natural rock, and composites, its application to jet grouting materials is rarely reported. Core samples were obtained from an active construction site, specifically from a coarse-grained soil layer, and were subjected to laboratory testing to evaluate key mechanical parameters such as: compressive strength, stiffness, and stiffness-to-strength ratios. The experimental approach aims to assess material variability and evaluate the relevance of standard modulus-based design parameters. The findings contribute to a deeper understanding of jet grout behavior and demonstrate the value of DIC as a complementary method for the performance assessment and design verification of jet grouted systems in coarse-grained soils.

1 January 2024
Verified
Conference Paper
Closed access
MSMilica Stojanović
Milica Stojanović
MŠMarina Škondrić
Marina Škondrić
Aleksandar RadevićAleksandar Radević
Aleksandar Radević
MPMarko Popović
Marko Popović
Aleksandar Radoje SavićAleksandar Radoje Savić
Aleksandar Radoje Savić
DJDragica Jevtić
Dragica Jevtić
The subject of the tests presented in this paper is the examination of the influence of the applied test method on the adhesion of concrete and reinforcement. In addition to the detailed characterization of concrete and reinforcement, adhesion tests were performed according to the stretching method and according to the modified Pull-out method, developed at the Faculty of Civil Engineering in Belgrade. The test were conducted on concrete samples, with centrally anchored bars with a diameter of 10 mm. The test results show that by eliminating the lateral pressures in the concrete, the achieved adhesion between the concrete and the reinforcement is significantly reduced.

1 January 2025 in Građevinski materijali i konstrukcije
Verified
Journal Article
Open access
PDF file
MPMilica Petrović
Milica Petrović
MPMarko Popović
Marko Popović
MŠMarina Škondrić
Marina Škondrić
Aleksandar Radoje SavićAleksandar Radoje Savić
Aleksandar Radoje Savić
Dimitrije ZakićDimitrije Zakić
Dimitrije Zakić
The paper presents the testing methods used for the contemporary masonry strengthening system, FRCM (fibre-reinforced cementitious matrix), which consists of glass fabric and mortar matrix. The FRCM system is suitable for strengthening masonry structures since it doesn't significantly change their mass and stiffness but increases the capacity for certain loads, especially ones induced by earthquakes. Following the recommendations, the mechanical properties of component materials and three groups (fibers, fibers in mortar, and masonry system) of specimens were tested. The main parameters necessary for calculating this system were defined and compared with the results found in the literature. It was shown that the chosen geometry for the mechanical test was appropriate for comparing the results within different groups. The importance of the type of fixtures used for the specimens (clevisor clamping-grip) was more pronounced in the second group of specimens. Results of the first and the third group of specimens were in accordance with the literature, with the ultimate tensile stress of the dry fabric reaching 742,2 MPa, and the ultimate tensile strain of the dry fabric reaching 1.53%.The conventional strain obtained from the third group of specimens was 1.28%.