Kyu-Bok Lee

Prof. Kyu-Bok Lee

Department of Prosthodontics, Kyungpook National University, Daegu 41490, Korea
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
YJYoo-Geum Jeong
Yoo-Geum Jeong
WLWan-Sun Lee
Wan-Sun Lee
Kyu-Bok LeeKyu-Bok Lee
Kyu-Bok Lee
Jeong YG, et al. J Adv Prosthodont. 2018 Jun;10(3):245-251. https://doi.org/10.4047/jap.2018.10.3.245

1 January 2017 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
WLWan-Sun Lee
Wan-Sun Lee
DLDu-Hyeong Lee
Du-Hyeong Lee
Kyu-Bok LeeKyu-Bok Lee
Kyu-Bok Lee
Lee WS, et al. J Adv Prosthodont. 2017 Aug;9(4):265-270. https://doi.org/10.4047/jap.2017.9.4.265

Verified
Journal Article
Open access
PDF file
KeunBaDa SonKeunBaDa Son
KeunBaDa Son
SLSangbong Lee
Sangbong Lee
SKSeok Hyon Kang
Seok Hyon Kang
JPJaeseok Park
Jaeseok Park
Kyu-Bok LeeKyu-Bok Lee
Kyu-Bok Lee
BYByoung-Ju Yun
Byoung-Ju Yun
Numerous studies have previously evaluated the marginal and internal fit of fixed prostheses; however, few reports have performed an objective comparison of the various methods used for their assessment. The purpose of this study was to compare five marginal and internal fit assessment methods for fixed prostheses. A specially designed sample was used to measure the marginal and internal fit of the prosthesis according to the cross-sectional method (CSM), silicone replica technique (SRT), triple scan method (TSM), micro-computed tomography (MCT), and optical coherence tomography (OCT). The five methods showed significant differences in the four regions that were assessed (p < 0.001). The marginal, axial, angle, and occlusal regions showed low mean values: CSM (23.2 µm), TSM (56.3 µm), MCT (84.3 µm), and MCT (102.6 µm), respectively. The marginal fit for each method was in the range of 23.2–83.4 µm and internal fit (axial, angle, and occlusal) ranged from 44.8–95.9 µm, 84.3–128.6 µm, and 102.6–140.5 µm, respectively. The marginal and internal fit showed significant differences depending on the method. Even if the assessment values of the marginal and internal fit are found to be in the allowable clinical range, the differences in the values according to the method should be considered.

1 May 2019 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
GPGun-Hong Park
Gun-Hong Park
KeunBaDa SonKeunBaDa Son
KeunBaDa Son
Kyu-Bok LeeKyu-Bok Lee
Kyu-Bok Lee


3 August 2021 in Healthcare
Verified
Journal Article
Open access
PDF file
KeunBaDa SonKeunBaDa Son
KeunBaDa Son
JLJung-Ho Lee
Jung-Ho Lee
Kyu-Bok LeeKyu-Bok Lee
Kyu-Bok Lee
This study aimed to evaluate the intaglio surface trueness of interim dental crowns fabricated with three 3-dimensional (3D) printing and milling technologies. Dental crown was designated and assigned as a computer-aided design (CAD) reference model (CRM). Interim dental crowns were fabricated based on CRM using two types of 3D printer technologies (stereolithography apparatus and digital light processing) and one type of milling machine (n = 15 per technology). The fabricated interim dental crowns were obtained via 3D modeling of the intaglio surface using a laboratory scanner and designated as CAD test models (CTMs). The alignment and 3D comparison of CRM and CTM were performed based on the intaglio surface using a 3D inspection software program (Geomagic Control X). Statistical analysis was validated using one-way analysis of variance and Tukey HSD test (α = 0.05). There were significant differences in intaglio surface trueness between the three different fabrication technologies, and high trueness values were observed in the milling group (p < 0.05). In the milling group, there was a significant difference in trueness according to the location of the intaglio surface (p < 0.001). In the manufacturing process of interim dental crowns, 3D printing technologies showed superior and uniform manufacturing accuracy than milling technology.