Various types of interference signals are available in the working environment of passive wireless surface acoustic wave (SAW) sensors. Among these kinds of interference, co-channel interference is difficult to suppress. To solve this problem, a SAW sensor anti-interference technology was proposed to improve the reliability of the SAW sensor. Wavelet denoising method was used to denoise SAW resonator (SAWR) response, which can maintain the envelope characteristics of the SAW response. The entropy energy model of the SAW response signal was established, and the signal envelope was extracted from the proposed entropy energy function. The waveform envelope and the entropy energy curve were adopted as the signal characteristics to form two-dimensional points. The K-Means algorithm was used to classify the two-dimensional points to distinguish the SAW response from sinusoidal interference. Simulation results showed that the SAW response can be detected with a rate of more than 85% when the signal-to-noise ratio was greater than 4 dB, whereas the false detection rate of the sinusoidal interference signal was less than 8%. Finally, the proposed algorithm was used to detect the actual SAW response and sinusoidal interference signal. The experimental results showed that the proposed method can clearly distinguish the SAW response from the co-channel interference signal. Moreover, the proposed method can be used as the anti-interference technology to improve the stability of the SAW sensor.
Compared with apodization, the piston-mode technique is a preferable solution to suppress the spurious transverse modes in surface acoustic wave (SAW) devices. This paper extends the technique to the SAW resonator (SAWR) strain sensors to achieve a high performance, that is, conquer some negative influence in the wireless strain sensing system caused by the spurious modes, such as low signal to noise ratio (SNR), high misreading rate and demodulation difficulty. The principle of piston-mode operation was presented and a modified expression was given for primary design of the piston-mode waveguide, which takes into account the anisotropy difference in different electrode regions. SAWRs based on the Al/ST-quartz with the conventional and two common piston-mode configurations were designed, simulated, fabricated and measured. The experiments to evaluate the wireless performance and strain sensitivity of the SAWR strain sensors with different electrode configurations were performed.
This paper presents an effective surface acoustic wave (SAW) response detection method for the passive wireless SAW torque sensor to improve the measurement accuracy. An analysis was conducted on the relationship between the response energy-entropy and the bandwidth of SAW resonator (SAWR). A self-correlation method was modified to suppress the blurred white noise and highlight the attenuation characteristic of wireless SAW response. The SAW response was detected according to both the variation and the duration of energy-entropy ascension of an acquired RF signal. Numerical simulation results showed that the SAW response can be detected even when the signal-to-noise ratio (SNR) is 6dB. The proposed SAW response detection method was evaluated with several experiments at different conditions. The SAW response can be well distinguished from the sinusoidal signal and the noise. The performance of the SAW torque measurement system incorporating the detection method was tested. The obtained repeatability error was 0.23% and the linearity was 0.9934, indicating the validity of the detection method.
This paper presents an original passive wireless rotation speed measurement method based on surface acoustic wave (SAW) technology. A theoretical analysis was conducted on the principle of SAW...
Chronic obstructive pulmonary disease (COPD) is a persistent and progressive respiratory disorder characterized by expiratory airflow limitation caused by chronic inflammation. Evidence has shown that COPD is correlated with neutrophil chemotaxis towards the airways, resulting in neutrophilic airway inflammation. This study aimed to evaluate neutrophil chemotaxis in bronchoalveolar lavage fluid (BALF) from COPD patients using a high-throughput nine-unit microfluidic platform and explore the possible correlations between neutrophil migratory dynamics and COPD development. The results showed that BALF from COPD patients induced stronger neutrophil chemotaxis than the Control BALF. Our results also showed that the chemotactic migration of neutrophils isolated from the blood of COPD patients was not significantly different from neutrophils from healthy controls, and neutrophil migration in three known chemoattractants (fMLP, IL-8, and LTB4) was not affected by glucocorticoid treatment. Moreover, comparison with clinical data showed a trend of a negative relationship between neutrophil migration chemotactic index (C. I.) in COPD BALF and patient’s spirometry data, suggesting a potential correlation between neutrophil migration and the severity of COPD. The present study demonstrated the feasibility of using the microfluidic platform to assess neutrophil chemotaxis in COPD pathogenesis, and it may serve as a potential marker for COPD evaluation in the future.
In order to improve the measurement accuracy of surface acoustic wave (SAW) torque sensor, an ultra-high precision SAW torque sensor demodulation method based on multi-objective bat algorithm (MOBA) and root-MUSIC algorithm was proposed. The root-MUSIC algorithm was adopted to construct the polynomial equation of SAW echo signals. The construction of the objective function was based on two principles: the least distance to unit circle and least phase angle to the mean roots. MOBA was used to optimize the objective function to improve the accuracy of the roots. The numerical simulation and actual interrogating experiments were carried out and comparisons with other methods were conducted. The demodulation results verified that the proposed method had a minimum estimation error with standard deviation of 1Hz. The designed demodulation method was used to the SAW torque measurement system. The torque sensing SAW resonator was designed using a FEM software and manufactured with a frequency of 433.945MHz and an unload Q factor of 13370. The SAW resonator was glued on a bearing to measure applied torque. The torque loading and unloading experiments demonstrated that the nonlinearity of the proposed method was 0.1402%, which is the minimum when compared to other methods. The hysteresis was 1.1791%, and the sensitivity was 1.3570kHz/Nm. Numerical simulation and experimental results demonstrated the effectiveness and accuracy of the designed algorithm in SAW torque sensor demodulation system.