Raphael Salomon Wagner

Dr. Raphael Salomon Wagner

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2021 in Biology
Verified
Journal Article
Open access
PDF file
MRMarco Aoqi Rausch
Marco Aoqi Rausch
HSHassan Ali Shokoohi-Tabrizi
Hassan Ali Shokoohi-Tabrizi
CWChristian Wehner
Christian Wehner
BPBenjamin Pippenger
Benjamin Pippenger
RWRaphael Salomon Wagner
Raphael Salomon Wagner
OAOleh Andrukhov
Oleh Andrukhov
Due to the rising demand for zirconia (Zr) based implant systems, it is important to understand the impact of Zr and titanium (Ti) implants and particularly their topography on soft tissue healing. As human gingival fibroblasts (hGFs) are the predominant cells in peri-implant soft tissue, we focused on examining the effect of implant material and surface roughness on hGFs’ initial attachment, growth and the expression of proteins involved in the focal adhesion. hGFs isolated from eight healthy donors were cultured on the following surfaces: smooth titanium machined surface (TiM), smooth zirconia machined surface (ZrM), moderately rough titanium surface (SLA), or moderately rough zirconia surface (ZLA) for up to 14 days. The initial attachment of hGFs was evaluated by scanning electron microscopy. Cell proliferation/viability was assessed by cell counting kit 8. Focal adhesion and cytoskeleton were visualized by a focal adhesion staining kit. The gene expression of focal adhesion kinase (FAK), α-smooth muscle actin (α-SMA), and integrin subunits ITG-β1, ITG-β4, ITG-α4, ITG-α5, ITG-α6, was evaluated by qPCR. Cell proliferation/viability was slightly decreased by moderately rough surfaces, whereas no effect of surface material was observed. Cell morphology was strikingly different between differently treated surfaces: on machined surfaces, cells had elongated morphology and were attached along the grooves, whereas on moderately rough surfaces, cells were randomly attached. Surface roughness had a more pronounced effect on the gene expression compared to the surface material. The expression of FAK, α-SMA, ITG-β4, ITG-α5, and ITG-α6 was enhanced by moderately rough surfaces compared to smooth surfaces. Within the limitations of this in vitro study, it can be concluded that the behavior of primary hGFs is primarily affected by surface structure, whereas no apparent advantage of Zr over Ti could be observed.

1 October 2021 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Open access
Fei PanFei Pan
Fei Pan
SAStefanie Altenried
Stefanie Altenried
FZFlavia Zuber
Flavia Zuber
RWRaphael Salomon Wagner
Raphael Salomon Wagner
Yen-Hsun SuYen-Hsun Su
Yen-Hsun Su
QRQun Ren
Qun Ren
Titanium (Ti)-based implants are broadly applied in the medical field, but their related infections can lead to implant failure. Photo-irradiation of metal materials to generate antimicrobial agents, an alternative to antibiotics, is a promising method to reduce bacterial infection and antibiotic usage. It is therefore important to understand how bacterial pathogens respond to Ti surfaces. Here, Gram-negative Pseudomonas aeruginosa and Gram-positive Staphylococcus aureus, the most prevalent pathogens linked to healthcare-associated infections, were used as model strains. Two different kinds of Ti surfaces respectively stored in dry condition and 0.9 % NaCl solution were applied. Upon UV irradiation and in the absence of bacteria, both tested surfaces exhibited similar bactericidal activity, even though the surfaces stored in 0.9 % NaCl solution generated a slightly higher level of reactive oxygen species (ROS). Interestingly, P. aeruginosa and S. aureus responded to the irradiated Ti surfaces differently regarding interaction time: the number of viable P. aeruginosa was reduced up to 90 % after 30 min interaction with the treated surfaces compared to the untreated ones, but this reduction is lessened to 69 %-81 % after 240 min. By contrast, UV treatment of surfaces did not impact the viability of S. aureus after 30 min interaction, however, led to more than 99 % reduction after 240 min incubation. These results provide first experimental evidence that Gram negative and positive bacterial species respond to ROS with different inactivation kinetics. This work also demonstrated that treatment with photo-irradiation in the absence of bacteria conferred Ti surfaces with efficient bactericidal activity.

4 January 2026 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
MRMarco Aoqi Rausch
Marco Aoqi Rausch
ZTZhiwei Tian
Zhiwei Tian
VMVera Maierhofer
Vera Maierhofer
CBChristian Behm
Christian Behm
CUChristian Ulm
Christian Ulm
OAOleh Andrukhov
Oleh Andrukhov
Background/Objectives: Formation of tight contacts between oral soft tissue and dental implants is a significant challenge in contemporary implantology. An essential role in this process is played by oral epithelial cells. In the present study, we investigated how titanium and zirconia surfaces with different roughness influence various parameters of oral epithelial cells in vitro. Methods: We used the human oral squamous carcinoma Ca9-22 cell line and cultured them on the following surfaces: machined smooth titanium (TiM) and zirconia (ZrM) surfaces, as well as sandblasted and acid-etched titanium moderately rough (SLA) and zirconia (ZLA) surfaces. Cell proliferation/viability was measured by CCK-8 assay, and cell morphology was analyzed by fluorescent microscopy. The gene expression of interleukin (IL)-8, intercellular adhesion molecule (ICAM)-1, E-cadherin, integrin (ITG)-α6, and ITG-β4 was measured by qPCR, and the content of IL-8 in conditioned media by ELISA. Results: At the initial culture phase, cell proliferation was promoted by rougher surfaces. Differences in cell attachment were observed between machined and moderately rough surfaces. Machined surfaces were associated with slightly higher IL-8 levels (p < 0.05). Furthermore, both ZLA and SLA surfaces promoted the expression of (ITG)-α, ITG-β4, and ICAM-1 in Ca9-22 cells (p < 0.05). Surface material had no impact on the investigated parameters. Conclusions: Under the limitations of this in vitro study, some properties of oral epithelial cells, particularly the immunological and barrier function, are moderately modified by roughness but not by material. Hence, the roughness of the implant surface might play a role in the quality of the peri-implant epithelium.