Pressure drop has been measured for upward single- and two-phase gas–liquid flow across an orifice in a vertical pipe. A conductance probe provided average void fraction upstream of the orifice. Six orifices with different apertures/thickness were mounted in turn in a 34 mm diameter transparent acrylic resin pipe. Gas and liquid superficial velocities of 0–4 m/s and 0.3–0.91 m/s, respectively, were studied. For single-phase flow, pressure drop, expressed as an Euler number, was seen to be independent of Reynolds number in turbulent region. The Euler number increased with decreasing the open area ratio/orifice thickness and increasing velocity. The pressure drop was well predicted by the correlation of Idel'chik et al. (1994, Handbook of Hydraulic Resistances, 3rd ed., CRC Press, Boca, Raton, FL.), which uses a form of Euler number. The corresponding two-phase flow pressure drop depends on the flow pattern. Decreasing open area ratio/orifice thickness increased the pressure drop. For a given liquid superficial velocity, the pressure drop increases with gas superficial velocity except for low open area ratio where this increase is followed by a decrease beyond a critical superficial gas velocity for the high liquid superficial velocities. Relevant correlations were assessed using the present data via a systematic statistical approach. The two-phase multiplier equations of Morris (1985, “Two-Phase Pressure Drop Across Valves and Orifice Plates,” European Two Phase Flow Group Meeting, Marchwood Engineering Laboratories, Southampton, UK.) and Simpson et al. (1983, “Two-Phase Flow Through Gate Valves and Orifice Plates,” International Conference on Physical Modelling of Multiphase Flow, Coventry, UK.) are the most reliable ones.
2 March 2023 in Journal of Energy Resources Technology
This paper presents an experimental investigation of the pressure drop (DP) through valves in vertical upward flows. Experiments were carried out using a 1¼″ (DN 32) ball and gate valve. Five opening areas have been investigated from fully open to the nearly fully closed valve, using air with a superficial velocity of 0–3.5 m/s and water 0.05–0.91 m/s. These ranges cover single-phase and the bubbly, slug and churn two-phase flow regimes. It was found that for the single-phase flow experiments, the valve coefficient increases with the valve opening and is the same, in both valves, for the openings smaller than 40%. The single-phase pressure drop increases with the liquid flowrate and decreases with the opening area. The two-phase flow pressure drop was found considerably increased by reducing the opening area for both valves. It reaches its maximum values at 20% opening for the ball valve and 19% opening for the gate valve. It was also inferred that at fully opening condition, the two-phase flow multiplier, for both valves, has been found close to unity for most of the tested flow conditions. For 40 and 20% valve openings the two-phase multiplier decreases in the power-law with liquid holdup for the studied flow conditions. Models proposed originally for evaluating the pressure drop through an orifice in single-phase and two-phase flows were also applied and assessed in the present experimental data.
14 March 2020 in The Canadian Journal of Chemical Engineering
Experimental results on hydrodynamic behavior and pressure drop of two-phase mixture flowing upwardly in a pipe containing single- and/or multi-hole orifice plate are presented. It was found from the measurement of the void fraction upstream and downstream the orifices that the flow behavior is significantly affected by the layout of the orifice plate used and the flow starts to recover after approximately 7D downstream the orifice. Furthermore, increasing orifice holes number results in decreasing the slip ratio. The standard deviation of the void fraction was used to identify the flow pattern before and after the orifices and found that the critical threshold transition occurred at a standard deviation of 0.2. The flow homogenization necessitates a minimum value of the liquid superficial velocity to occur, and the position where it takes place depends on this velocity and on the orifice holes number. It was also inferred from the two-phase pressure drop data across the orifices that three different flow regimes, where the transition between bubbly-to-slug and slug-to-churn flow, can be identified. An assessment of the predicted two-phase flow multiplier using some previous models dedicated to single-hole orifice was achieved; and found that the model proposed by Simpson et al. is the most reliable one. Single-phase pressure drop was also measured and compared with correlations from literature.
An accurate prediction of the liquid holdup and pressure drop using the one-dimensional mechanistic slug flow models requires an accurate estimation of slug void fraction. Considerable theoretical and experimental research has been conducted in the literature to study the slug void fraction. However, almost, all these studies primarily focus on the vertical upward and horizontal slug flows. In this study, we investigated experimentally and theoretically the slug void fraction in vertical downward flow. A series of experiments for measuring the slug void fraction in air–water flow using the conductance probe technique with a pipe diameter of 34 mm were conducted. The relationship between the measured slug void fraction and the mixture velocity revealed the presence of three distinct zones. This observed behavior, which differs from what has been reported in vertical upward flow, was explained through a mechanistic model that considers the varying velocities of liquid slugs, small gas bubbles, and Taylor bubbles. A new empirical predictive model based on the liquid-to-gas superficial velocities ratio and input liquid fraction was proposed. The performance of the proposed model was compared to existing models and demonstrated the lowest error. It showed a good performance with an average relative error of −3.43% and an average absolute relative error of 12.97%. The assessment study of the existing models developed for vertical upward flow showed that they failed to predict correctly the slug void fraction in vertical downward flow.