Jae Eun Song

Dr. Jae Eun Song


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2025 in Tomography
Verified
Journal Article
Open access
PDF file
SPSang Won Park
Sang Won Park
Doohee LeeDoohee Lee
Doohee Lee
JSJae Eun Song
Jae Eun Song
YKYoon Kim
Yoon Kim
HCHyun-Soo Choi
Hyun-Soo Choi
OKOh Beom Kwon
Oh Beom Kwon
Background: Accurate confirmation of nasogastric (NG) tubes is essential for patient safety, but delays and variability in interpretation remain common in clinical practice. Deep learning (DL) models have shown potential for assisting in this task, but real-world performance, particularly in detecting malpositioned tubes, remains insufficiently characterized. Methods: We conducted a pilot evaluation of a previously developed DL model using 135 chest radiographs from Kangwon National University Hospital. Expert physicians established the reference standard. Model performance was assessed and receiver operating characteristic (ROC) curve and precision recall curve (PRC) analyses were performed. Differences between correctly classified and misclassified cases were examined using Wilcoxon rank-sum and Fisher’s exact tests to explore potential clinical or radiographic contributors to model failure. Results: The model correctly classified 129 of 135 cases. The sensitivity was 96.1% (95% confidence interval (CI): 92.2–98.9%), specificity was 85.7% (95% CI: 42.2–97.7%), positive predictive value (PPV) was 99.2% (95% CI: 96.1–99.9%), negative predictive value (NPV) was 54.5% (95% CI: 25.4–80.8%), balanced accuracy was 90.8%, and F1-score was 0.976. The area under the ROC curve was 0.970 (95% CI: 0.929–1.000) and that under the PRC was 0.727 (95% CI: 0.289–1.000), reflecting substantial uncertainty related to the very small number of incomplete cases (n = 6). No statistically significant differences in clinical or radiographic characteristics were observed between correctly classified and misclassified cases. Conclusions: The DL model performed well in identifying correctly positioned NG tubes but demonstrated limited and unstable performance for detecting incomplete placements. Given the safety implications of misclassification, the model should be used only as an assistive tool with mandatory physician oversight. Larger, multi-center studies with greater representation of incomplete cases are required to obtain more reliable estimates and support safe clinical implementation.