Christoph Tremmel

Dr. Christoph Tremmel


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2022 in Journal of Neural Engineering
Verified
Journal Article
Open access
CTChristoph Tremmel
Christoph Tremmel
JFJacobo Fernandez-Vargas
Jacobo Fernandez-Vargas
DSDimitris Stamos
Dimitris Stamos
Caterina CinelCaterina Cinel
Caterina Cinel
MPMassimiliano Pontil
Massimiliano Pontil
RPRiccardo Poli
Riccardo Poli
Objective. We investigated whether a recently introduced transfer-learning technique based on meta-learning could improve the performance of brain–computer interfaces (BCIs) for decision-confidence prediction with respect to more traditional machine learning methods. Approach. We adapted the meta-learning by biased regularisation algorithm to the problem of predicting decision confidence from electroencephalography (EEG) and electro-oculogram (EOG) data on a decision-by-decision basis in a difficult target discrimination task based on video feeds. The method exploits previous participants’ data to produce a prediction algorithm that is then quickly tuned to new participants. We compared it with with the traditional single-subject training almost universally adopted in BCIs, a state-of-the-art transfer learning technique called domain adversarial neural networks, a transfer-learning adaptation of a zero-training method we used recently for a similar task, and with a simple baseline algorithm. Main results. The meta-learning approach was significantly better than other approaches in most conditions, and much better in situations where limited data from a new participant are available for training/tuning. Meta-learning by biased regularisation allowed our BCI to seamlessly integrate information from past participants with data from a specific user to produce high-performance predictors. Its robustness in the presence of small training sets is a real-plus in BCI applications, as new users need to train the BCI for a much shorter period. Significance. Due to the variability and noise of EEG/EOG data, BCIs need to be normally trained with data from a specific participant. This work shows that even better performance can be obtained using our version of meta-learning by biased regularisation.

1 December 2024 in Journal of Neural Engineering
Verified
Journal Article
Open access
CTChristoph Tremmel
Christoph Tremmel
DKDean J Krusienski
Dean J Krusienski
MSM.c. Schraefel
M.c. Schraefel
Objective. This study investigated the potential of estimating various mental workload levels during two different tasks using a commercial in-ear electroencephalography (EEG) system, the IDUN ‘Guardian’. Approach. Participants performed versions of two classical workload tasks: an n-back task and a mental arithmetic task. Both in-ear and conventional EEG data were simultaneously collected during these tasks. In an effort to facilitate a more comprehensive comparison, the complexity of the tasks was intentionally increased beyond typical levels. Special emphasis was also placed on understanding the significance of γ band activity in workload estimations. Therefore, each signal was analyzed across low frequency (1–35 Hz) and high frequency (1–100 Hz) ranges. Additionally, surrogate in-ear EEG measures, derived from the conventional EEG recordings, were extracted and examined. Main results. Workload estimation using in-ear EEG yielded statistically significant performance levels, surpassing chance levels with 44.1% for four classes and 68.4% for two classes in the n-back task and was better than a naive predictor for the mental arithmetic task. Conventional EEG exhibited significantly higher performance compared to in-ear EEG, achieving 80.3% and 92.9% accuracy for the respective tasks, along with lower error rates than the naive predictor. The developed surrogate measures achieved improved results, reaching accuracies of 57.5% and 85.5%, thus providing insights for enhancing future in-ear systems. Notably, most high frequency range signals outperformed their low frequency counterparts in terms of accuracy validating that high frequency γ band features can improve workload estimation. Significance. The application of EEG-based Brain–Computer Interfaces beyond laboratory settings is often hindered by practical limitations. In-ear EEG systems offer a promising solution to this problem, potentially enabling everyday use. This study evaluates the performance of a commercial in-ear headset and provides guidelines for increased effectiveness.

8 April 2025 in Journal of Medical Internet Research
Verified
Journal Article
Open access
CTChristopher Tacca
Christopher Tacca
AGArturo Vazquez Galvez
Arturo Vazquez Galvez
ITIsobel Thompson
Isobel Thompson
ABAlexander Dawid Bincalar
Alexander Dawid Bincalar
CTChristoph Tremmel
Christoph Tremmel
MSM.c. Schraefel
M.c. Schraefel
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: The population is aging and research on maintaining and extending older adult independent living is growing in interest. An approach towards building and sustaining quality of life is to develop interactive technologies to support elder independent living through fitness. However, reviews of current fitness technologies for elders indicate that the success of these technologies is considerably limited. Objective: This scoping review aims to investigate the reason for the limited outcomes from these technologies by comparing current fitness technology interventions to known needs and preferences of elders from elder specific technology acceptance research, barriers and enablers to elder physical activity, and qualitative research on elder fitness technologies. The scoping review questions investigated are: 1. How well do current elder fitness technologies align with known elder preferences? 2. How well do current research methodologies evaluate the known needs and preferences of elder adults? Methods: Our review was conducted in compliance with the PRISMA guidelines for scoping reviews (PRISMA-ScR). Research articles from the last ten years were searched in the ACM Digital Library, IEEE Xplore, Medline, and PsycINFO databases using the key words related to older adults, technology, and exercise. Research articles were filtered only include articles that specifically evaluated technologies for fitness, focused specifically on elders, and mentioned a specific technology used in the intervention. Reviewed research articles were evaluated versus known needs and preferences of elders related to fitness technology. The assessment criteria were synthesized into an assessment tool called the Elder Fitness Technology Assessment tool through literature on elder technology acceptance, barriers and enablers to elder physical activity, and qualitative research on elder fitness technologies. Interventions were scored by five reviewers using a dual-review approach. Results: 43 research articles were selected in the scoping review. 16 of the reviewed articles were from medical journals, 15 from engineering journals, seven from HCI or computing journals, three from public health, and two from a combined computing and engineering journal. Only 16 of the 43 research articles cited elder specific design works. The Elder Fitness Technology Translation Assessment tool was synthesized from known preferences of elders with the follow six factors: 1. Compatibility with Lifestyle, 2. Similarity with Past Experience, 3. Dignity and Independence, 4. Privacy Concerns, 5. Social Support, and 6. Emotion. The average scores for the 43 research articles across the six factors were 2.93±0.86 on Compatibility with Lifestyle, 3.10±0.74 on Similarity to Past Experience, 3.49±0.64 on Dignity and Independence, 3.17±0.86 on Privacy Concerns, 3.74±0.81 on Short-Term Outcomes, 2.75±1.21 on Long-Term Outcomes, 2.79±0.88 on Social Support, and 3.17±1.19 on Emotion. No research article scored a three or above on all the six elder specific factors. Conclusions: Overall, the results show a lack of alignment between the known preferences of elders related to technology and physical activity and the design and assessment of elder fitness technology interventions. Three main opportunities for growth are identified: 1. Better alignment between the studied needs of elders and current fitness technology interventions, 2. Better translation of findings from elder design work to designs in practice, and 3. More explicit usage of elder specific considerations in research methodologies. More explicit inclusion of elder specific factors in the design and assessment of elder fitness technologies is worth testing to evaluate how these established factors can support the development of more impactful interventions. We hypothesize that the proposed Elder Fitness Technology Translation Assessment tool can help bridge the gap between technological capability and real-world applicability, ultimately fostering greater adoption, respect for elders, and long-term success.

4 September 2025 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CTChristoph Tremmel
Christoph Tremmel
NHNathan T. M. Huneke
Nathan T. M. Huneke
DHDaniel Hobson
Daniel Hobson
MSM. C. Schraefel
M. C. Schraefel
Social Anxiety Disorder (SAD) is a prevalent and debilitating condition characterized by heightened anxiety and avoidance behaviors in social situations. Despite the availability of treatment options, remission rates for SAD remain low, highlighting the need for more effective interventions. To support the development of more effective therapies, a better understanding of the psychophysiological mechanisms underlying SAD is needed. This pilot study investigates whether anticipatory anxiety before a social interaction can be detected by multiple biosignals, with the aim of identifying potential biomarkers for SAD. Using a modified version of the Internet-based Stress Test for Social Anxiety Disorder, we measured physiological responses of 17 healthy volunteers, including heart rate, respiratory rate, electrodermal activity, head movements, and electroencephalography power across various frequencies. We found that anticipatory anxiety was associated with increased heart rate, respiratory rate, tonic EDA, and variance in head roll, alongside elevated theta, beta, and gamma power in EEG. Our results suggest that a combination of these biosignals may provide valuable insight into the psychophysiology of social anxiety, which could be useful for both mechanistic research and clinical applications. Future research should explore the role of these signals in clinical populations and during acute threat conditions to refine diagnostic and prognostic tools for SAD.

26 April 2025 in PsyArXiv
Verified
Preprint
Open access
CTChristoph Tremmel
Christoph Tremmel
NHNathan TM Huneke
Nathan TM Huneke
DHDaniel Hobson
Daniel Hobson
MSM.C. Schraefel
M.C. Schraefel
Social Anxiety Disorder (SAD) is a prevalent and debilitating condition characterized by heightened anxiety and avoidance behaviors in social situations. Despite the availability of treatment options, remission rates for SAD remain low, highlighting the need for more effective therapies. This pilot study investigates whether anticipatory anxiety before a social interaction can be detected through a combination of multiple biosignals, with the aim of identifying potential biomarkers for SAD. Using a modified version of the Internet-based Stress Test for Social Anxiety Disorder (ITSSAD), we measured physiological responses, including heart rate, respiratory rate, electrodermal activity, head movements, and EEG power across various frequencies. We found that anticipatory anxiety was associated with increased heart rate, respiratory rate, tonic EDA, and variance in head roll, alongside elevated theta, beta, and gamma power in EEG. Our results suggest that a combination of these biosignals may provide valuable insight into the psychophysiological profile of social anxiety, which could be useful for both mechanistic research and clinical applications. Future research should explore the role of these signals in clinical populations and during acute threat conditions to refine diagnostic and prognostic tools for SAD.

20 April 2023 in arXiv
Verified
Preprint
Open access
PDF file
CTChristoph Tremmel
Christoph Tremmel
IBIndu Bodala
Indu Bodala
MSM.c. Schraefel
M.c. Schraefel
In an effort to make biosignal integration more accessible to explore for more HCI researchers, this paper presents our investigation of how well a standard, near ubiquitous webcam can support remote sensing of heart rate and respiration rate across skin tone ranges. The work contributes: how the webcam can be used for this purpose, its limitations, and how to mitigate these limitations affordably, including how the skin tone range affect the estimation results.