José Maurício dos Santos Nunes Reis

Prof. Dr. José Maurício dos Santos Nunes Reis


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2023 in Brazilian Dental Journal
Verified
Journal Article
Open access
LCLívia Bueno Campi
Lívia Bueno Campi
ERElisandra Márcia Rodrigues
Elisandra Márcia Rodrigues
FTFernanda Ferrari Esteves Torres
Fernanda Ferrari Esteves Torres
JRJosé Maurício dos Santos Nunes Reis
José Maurício dos Santos Nunes Reis
JGJuliane Maria Guerreiro-Tanomaru
Juliane Maria Guerreiro-Tanomaru
MTMario Tanomaru-Filho
Mario Tanomaru-Filho
The aim of this study was to evaluate the physicochemical properties, cytotoxicity and bioactivity of a ready-to-use bioceramic material, Bio-C Repair (Angelus), in comparison with White MTA (Angelus) and Biodentine (Septodont). The physicochemical properties of setting time, radiopacity, pH, solubility, dimensional and volumetric changes were evaluated. Biocompatibility and bioactivity were assessed in Saos-2 osteoblast cell cultures by the MTT assay 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide), Neutral Red (NR), Alizarin Red (ARS), and cell migration tests. Statistical analysis was performed by ANOVA, Tukey or Bonferroni tests (α = 0.05). Bio-C Repair had the longest setting time (p < 0.05), but radiopacity and solubility were accordance with the ISO 6876/2012 standards, besides linear expansion. Bio-C Repair and MTA had similar volumetric change (p > 0.05); lower than Biodentine (p < 0.05). All the materials evaluated had an alkaline pH. Bio-C Repair was cytocompatible and promoted mineralized nodule deposition in 21 days and cell migration in 3 days. In conclusion, Bio-C Repair had adequate radiopacity above 3mm Al, solubility less than 3%, dimensional expansion, and low volumetric change. In addition, Bio-C Repair promoted an alkaline pH and presented bioactivity and biocompatibility similar to MTA and Biodentine, showing potential for use as a repair material.

1 August 2015 in International Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
YOY. Oguz
Y. Oguz
EWE.R. Watanabe
E.R. Watanabe
JRJosé Maurício dos Santos Nunes Reis
José Maurício dos Santos Nunes Reis
RSR. Spin-Neto
R. Spin-Neto
MGMarisa Aparecida Cabrini Gabrielli
Marisa Aparecida Cabrini Gabrielli
VFValfrido Antonio Pereira Filho
Valfrido Antonio Pereira Filho

1 June 2016 in British Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Open access
LOLeandro Benetti De Oliveira
Leandro Benetti De Oliveira
JRJosé Maurício dos Santos Nunes Reis
José Maurício dos Santos Nunes Reis
RSRubens Spin-Neto
Rubens Spin-Neto
MGMarisa Aparecida Cabrini Gabrielli
Marisa Aparecida Cabrini Gabrielli
YOYener Oguz
Yener Oguz
VFValfrido Antonio Pereira Filho
Valfrido Antonio Pereira Filho
We have evaluated the resistance to displacement of six stable methods of fixation of a sagittal split ramus osteotomy (SSRO) in the mandibular advancement with counterclockwise rotation. We tested 60 synthetic hemimandibles in six groups of 10 each: Group I - fixation with a straight four-hole 2.0mm miniplate; Group II - a straight six-hole 2.0mm miniplate; Group III - two straight 2.0mm four-hole miniplates; Group IV - an eight-hole 2.0mm (grid plate); Group V - a 2.0mm four-hole straight miniplate and 2.0×12mm bicortical screw; and Group VI - a straight four-hole 2.0mm locking miniplate. We applied a linear force in the region between the canine and the first premolar using a universal testing machine (EMIC- DL2000) with a loading cell of 10 KN. The loads at 1, 3, and 5mm displacement were recorded (N) and the data transmitted from the load cell to a computer. Results were analysed using analysis of variance (ANOVA) (p<0.001) and the Tukey post-test for comparison of the significance of the differences between the groups. For the three degrees of displacement, fixation with two straight 2.0mm plates and with the grid plate gave higher load values.

1 December 2018 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
GPGabriela Scatimburgo Polli
Gabriela Scatimburgo Polli
GHGabriel Rodrigues Hatanaka
Gabriel Rodrigues Hatanaka
FAFilipe de Oliveira Abi-Rached
Filipe de Oliveira Abi-Rached
MGMárcio Sousa Góes
Márcio Sousa Góes
JRJosé Maurício dos Santos Nunes Reis
José Maurício dos Santos Nunes Reis

23 November 2019 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Closed access
JRJosé Maurício dos Santos Nunes Reis
José Maurício dos Santos Nunes Reis
COCarlos R. de Moura Oliveira
Carlos R. de Moura Oliveira
ERErica G. J. Reis
Erica G. J. Reis
BMBruno A. Mascaro
Bruno A. Mascaro
FAFilipe de Oliveira Abi‐Rached
Filipe de Oliveira Abi‐Rached

25 July 2025 in Journal of Dentistry
Verified
Journal Article
Closed access
BMBruno Arruda Mascaro
Bruno Arruda Mascaro
RCRafael Vázquez Conejo
Rafael Vázquez Conejo
Maria Tejada-CasadoMaria Tejada-Casado
Maria Tejada-Casado
RFRenata Garcia Fonseca
Renata Garcia Fonseca
JRJosé Maurício dos Santos Nunes Reis
José Maurício dos Santos Nunes Reis
MPMaría del Mar Pérez
María del Mar Pérez