Yamei Wang

Dr. Yamei Wang

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2024 in Applied Surface Science
Verified
Journal Article
Closed access
HLHao Liu
Hao Liu
YWYamei Wang
Yamei Wang
CMChunlan Ma
Chunlan Ma
YXYuzhou Xiao
Yuzhou Xiao
RDRuirui Deng
Ruirui Deng
JFJiyu Fan
Jiyu Fan

30 January 2026 in Physical Review B
Verified
Journal Article
Closed access
SWSiyu Wang
Siyu Wang
CWChao Wang
Chao Wang
YYYanan Yuan
Yanan Yuan
JLJiangxiao Li
Jiangxiao Li
FPFangfang Pei
Fangfang Pei
QLQian Li
Qian Li

26 July 2024 in Thin Solid Films
Verified
Journal Article
Closed access
ZLZhipeng Long
Zhipeng Long
RYRui Yu
Rui Yu
XMXiangyu Meng
Xiangyu Meng
JLJunqin Li
Junqin Li
YWYamei Wang
Yamei Wang
YWYong Wang
Yong Wang

8 December 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SZShuo Zhao
Shuo Zhao
YZYing Zhao
Ying Zhao
YWYamei Wang
Yamei Wang
CHChun Hu
Chun Hu
JCJiefeng Cao
Jiefeng Cao
Chunpeng WangChunpeng Wang
Chunpeng Wang
The performance of synchrotron beamlines critically depends on the optimal coupling between the undulator and the monochromator. This work presents the implementation and quantitative characterization of a synchronized scanning system for the elliptically polarizing undulator (EPU) and the variable-line-spacing plane-grating monochromator at the BL07U beamline of the Shanghai Synchrotron Radiation Facility (SSRF). The system ensures that the monochromator’s narrow bandwidth dynamically tracks the brilliant central cone of the undulator radiation. A linear correlation between the monochromator energy and the undulator gap, justified theoretically for small scan ranges and reinforced by a robust real-time calibration procedure, forms the control basis. The automation is built upon a standard software stack comprising EPICS for device control, the Bluesky Suite for experimental orchestration, and Phoebus for the human–machine interface. Through comparative X-ray absorption spectroscopy (XAS) measurements at the Fe L2,3-edges, the synchronized mode is shown to enhance beam brilliance by 37% and stabilize the incident flux, reducing its variation from 4.2% to 1.8%. This directly results in absorption spectra with superior lineshape fidelity, a 40% reduction in noise, and the elimination of pre- and post-edge artifacts, unequivocally isolating the synchronization effect. This advancement provides a stable, high-brilliance photon source essential for high-quality XAS and X-ray magnetic circular/linear dichroism (XMCD/XMLD) studies.