María Carmen Yebra-Biurrun

Prof. Dr. María Carmen Yebra-Biurrun


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications


1 January 2012 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
PDF file
MYMaría Carmen Yebra-Biurrun
María Carmen Yebra-Biurrun
A simple and rapid analytical method was developed for the determination of iron, manganese, and zinc in soluble solid samples. The method is based on continuous ultrasonic water dissolution of the sample (5–30 mg) at room temperature followed by flow injection flame atomic absorption spectrometric determination. A good precision of the whole procedure (1.2–4.6%) and a sample throughput of ca. 25 samples h–1were obtained. The proposed green analytical method has been successfully applied for the determination of iron, manganese, and zinc in soluble solid food samples (soluble cocoa and soluble coffee) and pharmaceutical preparations (multivitamin tablets). The ranges of concentrations found were 21.4–25.61 μg g-1for iron, 5.74–18.30 μg g-1for manganese, and 33.27–57.90 μg g-1for zinc in soluble solid food samples and 3.75–9.90 μg g-1for iron, 0.47–5.05 μg g-1for manganese, and 1.55–15.12 μg g-1for zinc in multivitamin tablets. The accuracy of the proposed method was established by a comparison with the conventional wet acid digestion method using a pairedt-test, indicating the absence of systematic errors.

15 September 2012 in International Journal of Environmental Analytical Chemistry
Verified
Journal Article
Closed access
MYMaría Carmen Yebra-Biurrun
María Carmen Yebra-Biurrun
JCJesús M. Castro-Romero
Jesús M. Castro-Romero
An automatic on-line system is developed for the trace determination of copper and iron species in fresh waters by flame atomic absorption spectrometry using only 5 and 2 mL of sample, for copper and iron determination, respectively. This system, which includes a home-made minicolumn of commercially available resin containing aminomethylphosphonic acid functional groups (Chelite P), comprises two operational modes. The first, used for the determination of the dissolved labile fraction (free copper and iron ions and their weak complexes) is based on the elution of this fraction from a minicolumn containing the chelating resin loaded in-situ with the sample. The second mode is used for the determination of total trace copper and iron concentrations. This last mode is based on the retention/preconcentration of total metals on the Chelite P resin after on-line sonoassisted digestion of water samples acidified with nitric acid (0.5 mol L−1 final concentration) to break down metal organic complexes present in fresh waters as river waters. The figures of merit for copper and iron determination in both fractions are given and the obtained values are discussed. The analytical method was characterized and the limit of detection and limit of quantification for the two metals were 0.5 and 1.6 µg L−1 for Cu and 2.3 and 6.1 µg L−1 for Fe, respectively. The repeatability, expressed as relative standard deviation, was in the range 1.0–2.1%. The speciation scheme was applied to the analysis of river surface water samples collected in Galicia (Northwest, Spain).