Jacob Mbarndouka Taamté

Dr. Jacob Mbarndouka Taamté


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2024 in Journal of Instrumentation
Verified
Journal Article
Closed access
JTJacob Mbarndouka Taamté
Jacob Mbarndouka Taamté
MNMichaux Kountchou Noube
Michaux Kountchou Noube
VSVitrice Ruben Folifack Signing
Vitrice Ruben Folifack Signing
YHYerima Abba Hamadou
Yerima Abba Hamadou
Masahiro HosodaMasahiro Hosoda
Masahiro Hosoda
Shinji TokonamiShinji Tokonami
Shinji Tokonami
This article deals with the development of real-time air quality monitoring based on Unmanned Aerial Vehicles (UAVs) and low-cost Internet of Things (IoT) devices. This investigation aims to design and develop an UAV-based platform that can monitor a large number of air pollutants in real-time with high spatial and temporal resolution. The proposed environmental monitoring system consists of five main elements, namely the UAV, sensors, data storage module, programmable card, and IoT communication module. Estimated pollutants such as particulate matter (PM2.5) and toxic gases (carbon monoxide CO, nitrogen dioxide NO2, and carbon dioxide CO2) are detected by low-cost sensors. The ZigBee wireless protocol is used for communication between the PC and UAV. This work is carried out to assess the air quality in urban areas, given the heavy road traffic and the emissions of some companies. The data analyzed were collected from December 2, 2022 to January 3, 2023, in two major cities of Cameroon, Douala and Kribi. The periodic average values of the detected pollutants are 222 ± 22 μg/m3 and 85.7 ± 8.6 μg/m3 for PM2.5, 560.8 ± 1.0 ppm and 555.6 ± 1.0 ppm for CO2, 4.2 ± 0.2 ppm and 0.7 ± 0.1 ppm for NO2, and 27.6 ± 2.8 ppm and 4.5 ± 0.5 ppm for CO in Douala and Kribi respectively. This made it possible to have an air quality index (AQI) of 444.2 for Douala City and 171.3 for Kribi City. These high values indicate poor air quality during the measurement period.

19 March 2024 in Sustainable Chemical Engineering
Verified
Journal Article
Open access
PDF file
JTJacob Mbarndouka Taamté
Jacob Mbarndouka Taamté
VSVitrice Ruben Folifack Signing
Vitrice Ruben Folifack Signing
MBModibo Oumar Bobbo
Modibo Oumar Bobbo
KMKountchou Noubé Michaux
Kountchou Noubé Michaux
YHYerima Abba Hamadou
Yerima Abba Hamadou
SASaïdou
Saïdou
This article deals with the development and implementation of a low-cost smart air quality monitoring device. The study aims to develop a simple, efficient, and cheap device for real-time monitoring of Carbon dioxide (CO2) concentration and atmospheric parameters such as temperature (T) and relative humidity (RH). The realized device consists of sensors, a data storage system, a programmable card, and wireless modules for Internet of Things (IoT). It is designed for indoor and outdoor air quality monitoring. Wireless communication between the device and the control PC is ensured by the ZigBee protocol. The MH-Z14A sensor was calibrated according to the manufacturer’s recommendations and then experimentally in the laboratory. A calculation of the CO2 regression line for the devices using the least squares method gave R2 = 0.6889. The slope test using the Student method at a significant coefficient of 1% threshold and 19 degrees of freedom gave t(1%; 19) = 2.539. This illustrates that the result obtained by the realized device has less than a 1% chance of being obtained at random. An investigation was carried out to assess air quality because following the proliferation of pollutants, the normal concentration of atmospheric CO2 (400 ppm) has considerably changed. Thus, the data processed are outdoor concentrations collected in November 2022 in some localities of the Adamawa Region, Cameroon. The average values of CO2 concentration measured in four subdivisions are 497.30 ± 11.32 ppm in Ngaoundéré 1, 481.83 ± 14.90 ppm in Ngaoundéré 2, 568.63 ± 25.03 ppm in Martap and, 624.14 ± 3.96 ppm in Minim. Martap and Minim are among the most important bauxite deposits in the world. These CO2 values higher than the normal atmospheric concentration indicate a moderate Air Quality Index (AQI) in these cities during the measurement period. The designed device is inexpensive, reliable, and appropriate for air quality monitoring.

5 February 2025 in Smart Science
Verified
Journal Article
Closed access
JTJacob Mbarndouka Taamté
Jacob Mbarndouka Taamté
YSYvette Flore Tchuente Siaka
Yvette Flore Tchuente Siaka
NNNasser Nducol
Nasser Nducol
SYSusan Yakum-Ntaw Younui
Susan Yakum-Ntaw Younui
GAGouroudja Ahmadou
Gouroudja Ahmadou
SASaïdou
Saïdou

1 February 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
MNMichaux Kountchou Noube
Michaux Kountchou Noube
AIAlexandra Ioannidou
Alexandra Ioannidou
SDSa\{\ I} Dou
Sa\{\ I} Dou
EIEleftheria Ioannidou
Eleftheria Ioannidou
VSVitrice Ruben Folifack Signing
Vitrice Ruben Folifack Signing
ENEmmanouil Nikolaidis
Emmanouil Nikolaidis
This work addresses the problem of converting the analog measurement systems of older radiation monitoring instruments into fully digital automated measurement systems based on emerging technologies. For the purposes of this study, the outdated analog “BICRON Analyst” instrument will be completely transformed with new, more efficient digital instruments that are also easier to maintain, repair, and calibrate. Unlike the analog instrument, the digital instrument is more accurate providing the exact number of radioactive particles detected and the battery level. New technologies and efficient, cost-effective electronic components were used, namely a microcontroller board, which represents the central element of the digitization process, a digital display to replace the analog display and a micro-SD memory card module to record and store the measurement data in real time as well as a GPS module to determine the date, time and GPS coordinates of the location where the measurement was taken. First, laboratory tests were carried out to verify the proper functioning of the “BICRON Analyst” according to its operating instructions. The complete schematic circuit diagram and main board assembly (component side) of the instrument were used to identify the points (exact location) where the signals to be digitized must be taken from the electronic boards. The instrument was carefully disassembled to add and attach the new electronic components, and then the Arduino board was appropriately programmed to complete the digitization process. Calibration and operational control of the proper functioning of the fully digitized equipment was carried out using a Cs-137 gamma ray calibration source to determine the response of the instrument as a function of its distance from the radiation source. Given the generally high costs of laboratory equipment, cost-effective recycling of old, outdated and bulky analogue equipment is of great interest, particularly from an economic perspective.

7 April 2026 in African Journal of Aquatic Science
Verified
Journal Article
Closed access
JTJacob Mbarndouka Taamté
Jacob Mbarndouka Taamté
YSYvette Flore Tchuente Siaka
Yvette Flore Tchuente Siaka
SBSoumayah Bachirou
Soumayah Bachirou
GAGouroudja Ahmadou
Gouroudja Ahmadou
DGDieu Souffit Gondji
Dieu Souffit Gondji
SASaïdou
Saïdou

21 October 2025 in Research Square
Verified
Preprint
Open access
PDF file
NNNasser Nducol
Nasser Nducol
YSYvette Flore Tchuente Siaka
Yvette Flore Tchuente Siaka
AGAhmadou Gouroudja
Ahmadou Gouroudja
GONDJI Dieu SouffitGONDJI Dieu Souffit
GONDJI Dieu Souffit
JTJacob Mbarndouka Taamté
Jacob Mbarndouka Taamté
S-Saïdou -
Saïdou -
This investigation provides a qualitative and quantitative characterisation of the toxic trace elements contained in fine airborne particles (PM 2.5 ) collected in an urban site of Yaoundé. The aim is to determine the contribution of natural and anthropogenic sources, as well as to assess exposure, ecological and health risks. X-ray fluorescence spectrometry identified 17 toxic trace elements, including nine heavy metals (Fe, Zn, Cu, V, Co, Mn, Ni, Cr and Pb). Fe was the most abundant element, with a concentration of 1.56E-1 µg/m 3 , while V was the least abundant, with a concentration of 9.00E-5 µg/m 3 . Cross-analysis of the enrichment factor, contamination factor and geo-accumulation index as well as the K/Fe and V/Ni ratios, revealed a mixed (crustal and anthropogenic) origin for PM 2.5 , with a particularly high contribution from metal sources. These results highlight the multiplicity of sources, marked temporal variability and irregular emission frequency. The exposure risk assessment, based on measured concentrations and international guideline values, indicates a low-to-moderate risk for heavy metals and a high risk for PM 2.5 . The ecological risk index calculated for PM 2.5 was 282.39, reflecting a potentially moderate impact on ecosystems. Of the analysed heavy metals, only Ni, Mn and Co exhibited high hazard indices, indicating a significant probability of non-carcinogenic health effects. Furthermore, Ni and Co exhibit values that are significantly indicative of high carcinogenic risk. These findings emphasise the urgent need to implement strategies to reduce fine particle emissions and target metal sources in this urban environment.