Jung Uk Woo

Mr. Jung Uk Woo

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
WJWoo Sung Jang
Woo Sung Jang
JWJung Uk Woo
Jung Uk Woo
KSKyungsub Song
Kyungsub Song
Background: Although the concomitant Maze procedure successfully restores sinus rhythm in patients with valvular atrial fibrillation, it remains unclear whether electrical restoration translates into uniform functional recovery across different valvular etiologies. To address this issue, we compared the long-term left atrial (LA) mechanical recovery between patients with mitral stenosis (MS) and mitral regurgitation (MR) after the Maze procedure. Methods: This retrospective study included 211 patients who underwent the Maze procedure concomitant with valvular surgery and maintained sinus rhythm after 1 year. Patients were stratified into three groups, namely MS (n = 51), MR (n = 98), and non-mitral (n = 62) serving as a reference. LA function was evaluated using speckle-tracking echocardiography at baseline, immediately postoperatively, and at 1 year. Primary outcomes were changes in LA reservoir (LASr), LA conduit (LAScd), and LA contractile (LASct) strains. Results: At 1-year follow-up, the non-mitral reference group exhibited the best LA function, followed by the MR group, whereas the MS group showed the most impaired values (p < 0.001). Analysis of functional recovery revealed a mechanistic divergence, i.e., although the improvement in passive stiffness (LAScd) was comparable between the MS and MR groups (p = 0.42), the recovery of active contractile strain (LASct) was significantly superior in the MR group compared to the MS group (p < 0.05). The MS group failed to regain effective atrial contraction despite successful rhythm control. Conclusions: Although the Maze procedure successfully restored sinus rhythm, functional recovery varied significantly by etiology. The superior recovery in patients with MR was driven by the restoration of active atrial contraction, whereas patients with MS exhibited persistent mechanical dysfunction attributed to irreversible myocardial structural remodeling, despite similar improvements in compliance. Therefore, electrical success does not guarantee functional success, particularly in patients with MS.

1 May 2026 in Journal of Thoracic Disease
Verified
Journal Article
Open access
PDF file
JWJung Uk Woo
Jung Uk Woo
SYSungsil Yoon
Sungsil Yoon
WJWoo Sung Jang
Woo Sung Jang
YKYun Seok Kim
Yun Seok Kim
YBYo Han Bae
Yo Han Bae
KSKyungsub Song
Kyungsub Song
Background: Atrial functional mitral regurgitation (AFMR) is caused by atrial enlargement and mitral annular dilation due to atrial fibrillation (AF). Although the outcomes of mitral valve surgery in AFMR have been reported, concomitant Maze procedure outcomes in AFMR remain poorly understood. This study aimed to evaluate the clinical and rhythm outcomes of concomitant mitral valve plasty and the Maze procedure in patients with AFMR. Methods: We retrospectively analyzed 122 patients who underwent the mitral valve plasty (repair) concomitant with Maze procedure between August 2010 and June 2025. The cohort was divided into an AFMR group (n=50) and a non-AFMR group (n=72). The cumulative incidence of permanent pacemaker (PPM) implantation was analyzed using the Fine-Gray subdistribution hazard model with death as a competing risk. Postoperative rhythm dynamics were evaluated using a continuous-time multi-state Markov model. Results: The overall cumulative incidence of PPM implantation was significantly higher in the AFMR group than in the non-AFMR group (P30 days) PPM implantation (P<0.001). Multivariable analysis identified AFMR as an independent risk factor of late PPM implantation [subdistribution hazard ratios (sHR) 14.963, P=0.02]. Furthermore, the AFMR group demonstrated a higher rate of postoperative junctional rhythm compared to the non-AFMR group. Conclusions: AFMR was not associated with a statistically significant difference in overall survival and the incidence of major adverse cardiovascular events following the Maze procedure compared to the non-AFMR group. However, AFMR was associated with a higher risk of transition to junctional rhythm following the Maze procedure, which was associated with an increased rate of PPM implantation. Notably, the risk of pacemaker implantation was predominantly late-onset, which may be due to a progressive decline in sinus node function. Therefore, close long-term rhythm monitoring and follow-up are warranted.

1 January 2026 in Yonsei Medical Journal
Verified
Journal Article
Open access
PDF file
JWJung Uk Woo
Jung Uk Woo
YBYo Han Bae
Yo Han Bae
SYSungsil Yoon
Sungsil Yoon
WJWoo Sung Jang
Woo Sung Jang
YKYun Seok Kim
Yun Seok Kim
KSKyungsub Song
Kyungsub Song
Woo JU, et al. Yonsei Med J. 2026 ;67:e68. https://doi.org/10.3349/ymj.2025.0554

7 May 2026 in Journal of Yeungnam Medical Science
Verified
Journal Article
Open access
WJWoo Sung Jang
Woo Sung Jang
JWJung Uk Woo
Jung Uk Woo
KSKyungsub Song
Kyungsub Song
Background: The Emergency Bypass System (EBS, Terumo Corporation) and Permanent Life Support (PLS, MAQUET Cardiopulmonary GmbH) platforms differ in pump design and surface coating, which may influence hemocompatibility. This study compared the longitudinal hematological profiles and transfusion requirements of these systems.Methods: Adult patients who underwent extracorporeal membrane oxygenation were analyzed using 1:1 propensity score matching (74 matched pairs). The primary endpoints included hemoglobin and platelet trajectories during the first 5 days, which were analyzed using linear mixed-effects models.Results: In the matched cohort, both groups demonstrated statistically similar longitudinal declines in hemoglobin and platelet counts (p=0.525 and p=0.501, respectively). However, this apparent stability in the EBS group was achieved at a significantly higher hematological cost. Within 5 days, the EBS group required 25.5% more red blood cell transfusions (p<0.001) and 34.2% more platelet transfusions (p<0.001) than the PLS group. Multivariable analysis confirmed that the use of the PLS system was independently associated with a lower transfusion demand.Conclusion: Although laboratory trajectories were comparable during the acute phase, patients supported by EBS experienced a substantially higher transfusion burden. These findings suggest a masking effect, in which compensatory transfusions may obscure the accelerated blood cell consumption associated with EBS. Therefore, clinicians should remain vigilant regarding the potential hidden hematologic costs of EBS support, even when laboratory parameters appear stable.

21 November 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KSKyungsub Song
Kyungsub Song
YBYo Han Bae
Yo Han Bae
JWJung Uk Woo
Jung Uk Woo
SYSungsil Yoon
Sungsil Yoon
HLHee Jeong Lee
Hee Jeong Lee
JYJonghoon Yoo
Jonghoon Yoo
Background and Objectives: This study aimed to investigate risk factors for permanent pacemaker (PPM) implantation following the Maze procedure in patients with atrial functional mitral regurgitation (AFMR). Methods: A retrospective cohort of 423 patients who underwent the Maze procedure for persistent or paroxysmal atrial fibrillation from 2010 to 2025 was analyzed. Patients were categorized on the basis of the need for PPM postoperatively. Risk factors and rhythm outcomes were compared using multivariable Cox and logistic regression with backward stepwise selection according to the Akaike Information Criterion. Results: Forty-five patients (10.6%) required PPM implantation following the Maze procedure. The PPM group demonstrated a significantly higher AFMR prevalence than the non-PPM group (28.9% vs. 10.4%, p = 0.001). Preoperative fine P waves and older age were additional significant predictors. The PPM group exhibited lower postoperative sinus rhythm rates and higher junctional rhythm rates. AFMR (hazard ratio [HR], 2.10; p = 0.030), fine P wave (HR, 2.03; p = 0.049), and age (HR, 1.04; p = 0.018) independently predicted PPM implantation. AFMR particularly elevated the late PPM implantation risk. Conclusions: AFMR is an independent risk factor for late nodal dysfunction requiring PPM following Maze procedures. To detect delayed pacemaker requirements postoperatively, extended monitoring is recommended for patients with AFMR.