Jesús Brezmes

Dr. Jesús Brezmes

Spanish Biomedical Research Centre in Diabetes and Associated Metabolic Disorders (CIBERDEM), Madrid, Spain

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

19 April 2010 in Journal of Proteome Research
Verified
Journal Article
Closed access
MVMaria Vinaixa
Maria Vinaixa
MRMiguel Ángel Rodríguez-Gómez
Miguel Ángel Rodríguez-Gómez
Anna RullAnna Rull
Anna Rull
Raúl Beltrán-DebónRaúl Beltrán-Debón
Raúl Beltrán-Debón
CBCinta Blade
Cinta Blade
XCXavier Correig
Xavier Correig

1 May 2004 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
PIP. Ivanov
P. Ivanov
Eduard LlobetEduard Llobet
Eduard Llobet
Xavier VilanovaXavier Vilanova
Xavier Vilanova
JBJesús Brezmes
Jesús Brezmes
JHJ. Hubalek
J. Hubalek
XCXavier Correig
Xavier Correig

1 October 2000 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JBJesús Brezmes
Jesús Brezmes
Eduard LlobetEduard Llobet
Eduard Llobet
Xavier VilanovaXavier Vilanova
Xavier Vilanova
GSG Saiz
G Saiz
XCXavier Correig
Xavier Correig

1 January 2000 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
PDF file
Eduard LlobetEduard Llobet
Eduard Llobet
GMG. Molas
G. Molas
PMP. Molinàs
P. Molinàs
JCJ. Calderer
J. Calderer
Xavier VilanovaXavier Vilanova
Xavier Vilanova
PMP. Molinàs
P. Molinàs
Tungsten oxide is shown to be a very promising material for the fabrication of highly selective ammonia sensors. Films of were deposited onto a silicon substrate by means of the drop‐coating method. Then, the films were annealed in dry air at two different temperatures (300 and 400°C). X‐ray photoelectron spectroscopy was used to investigate the composition of the films. Tungsten appeared both in and oxidation states, but the second state was clearly dominant. Scanning electron microscopy results showed that the oxide was amorphous or nanocrystalline. The devices were sensitive to ammonia vapors when operated between 250 and 350°C. The optimal operating temperature for the highest sensitivity to ammonia was 300°C. Furthermore, when the devices were operated at 300°C, their sensitivity to other reducing species such as ethanol, methane, toluene, and water vapor was significantly lower, and this resulted in a high selectivity to ammonia. A model for the sensing mechanisms of the fabricated sensors is proposed. © 2000 The Electrochemical Society. All rights reserved.

1 November 2001 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JBJesús Brezmes
Jesús Brezmes
Eduard LlobetEduard Llobet
Eduard Llobet
Xavier VilanovaXavier Vilanova
Xavier Vilanova
JOJ. Orts
J. Orts
GSG. Saiz
G. Saiz
XCXavier Correig
Xavier Correig