The occurrence of electric arcs poses a huge threat to personal and equipment safety. As one of the effective ways to actively protect personnel and equipment away from serious arcing incidents, the signature recognition based arcing identification method has drawn much attention. However, since the strong nonlinear dynamics of the arcs, merely based on a specific time-domain or frequency-domain feature to develop the identification criteria may not be applicable in practice. To overcome the limitations, this article proposes a novel arc fault identification approach, which evaluated both the transient and steady dynamic states of arcing faults by time-frequency analysis. The complete ensemble empirical mode decomposition with adaptive noise, incorporated with Hilbert transform, has been designed to realize the rapid and reliable signatures extraction from arc fault profiles. Moreover, for dimension reduction purposes, correlation coefficient and partial least square regression based time-series dominant features selection method was developed. For ensuring the accuracy and robustness of the identification algorithm, a multiscenario based long short-term memory was also proposed. With the series of actual arc fault cases under different configurations, the effectiveness of the proposed method has.
The strong development of distributed energy sources has become one of the most important measures for low-carbon development worldwide. With a significant quantity of photovoltaic (PV) power generation being integrated to the grid, accurate and efficient prediction of PV power generation is an essential guarantee for the security and stability of the electricity grid. Due to the shortage of data from PV stations and the influence of weather, it is difficult to obtain satisfactory performance for accurate PV power prediction. In this regard, we present a PV power forecasting model based on a Fourier graph neural network (FourierGNN). Firstly, the hypervariable graph is constructed by considering the electricity and weather data of neighbouring PV plants as nodes, respectively. The hypervariance graph is then transformed in Fourier space to capture the spatio-temporal dependence among the nodes via the discrete Fourier transform. The multilayer Fourier graph operator (FGO) can be further exploited for spatio-temporal dependence information. Experiments carried out at six photovoltaic plants show that the presented approach enables the optimal performance to be obtained by adequately exploiting the spatio-temporal information.
This study investigates the economic operation of integrated energy systems under uncertainty, aiming to boost operational efficiency and cost-effectiveness while reducing carbon emissions. Unlike existing methods that either ignore the demand response or treat uncertainties separately, we introduce a two-stage robust optimization scheduling framework that simultaneously integrates demand-response mechanisms and carbon-emission costs. In Stage I, a preliminary dispatch is obtained for deterministic scenarios based on forecasted values of renewable outputs and load demands; in Stage II, the solution is refined against worst-case fluctuations in renewable output and load demand. A column-and-constraint generation algorithm facilitates efficient, iterative coordination between the two stages, resulting in an optimal and robust dispatch strategy. To validate our approach, we performed detailed numerical simulations on a standard benchmark for integrated energy systems commonly used in the literature. The results show that by accounting for multiple sources of uncertainty, the system’s energy cost fell from 7091.03 RMB to 6489.18 RMB—a saving of 8.49%—while the carbon emissions dropped from 6165.57 kg to 5732.54 kg, a reduction of 7.02%. Compared with conventional scenario-based dispatch methods, the proposed two-stage framework demonstrates superior adaptability and robustness in handling renewable generation and load uncertainties, providing strong technical backing and theoretical insights for the sustainable operation of integrated energy systems in uncertain environments.
13 January 2020 in IEEE Transactions on Industry Applications
Electronic current transducers based on Rogowski coil are commonly used for power system protection. However, they may generate additional dynamic components in some cases that may cause misoperation of protection devices. In order to check the hidden danger of this undesired phenomenon, this paper studies the transfer characteristics of Rogowski coil and proposes an approach to detect the possible occurrence of additional dynamic component phenomenon. Firstly, the root cause for the appearance of additional dynamic component is analyzed and investigated. Then, using the electromagnetic transient simulation modeling and variable delay scanning method, the simulation data of the grid operation is injected into the actual acquisition unit and the integral unit to obtain the output response of the current transducer. Therefore, the additional dynamic component phenomenon can be reproduced and identified. Finally, the test results of the application example demonstrate the effectiveness of the proposed method.
6 November 2023 in IEEE Transactions on Industry Applications
Accurate and reliable electric arc fault identification ensures the safety of personnel and equipment through in-field operations and maintenance work. However, due to the application scenarios and nonlinear arc dynamics, the distortion degree of the detectable signals is influenced by network/circuit structure, system parameter, operation manner, etc., the salience of the fault signatures may change significantly, which poses challenges to develop the “generic scheme” in arc faults identification. To address such issues, this paper proposed a robustness-improved arc fault identification approach that incorporates the modeling of dynamic impedance and chaotic behavior in faulting systems. For describing the “unique” nonlinear characteristics of arc faults among different operation scenarios, the HT-based dynamic impedance (HTDI) representation method is developed to extract the “signatures” of arc faults, and the mechanism of how system parameters impact the presentation form of arc fault features are also revealed. Meanwhile, for quantitively extracting the signatures, the chaotic behavior of arcing fault system has been analyzed in phase space in detail, with a series of chaos indicators. Additionally, HTDI and chaos indicators implemented LSTM classifier has been designed to achieve accurate and rapid arcing fault identification with time-series inputs. With the series of actual arc fault cases and simulation cases under different configurations, the effectiveness and robustness of the proposed method have been thoroughly validated.
To facilitate power system decarbonization, optimizing clean energy integration has emerged as a critical pathway for establishing sustainable power infrastructure. This study addresses the multi-timescale operational challenges inherent in power networks with high renewable penetration, proposing a novel stochastic dynamic programming framework that synergizes intraday microgrid dispatch with a multi-phase carbon cost calculation mechanism. A probabilistic carbon flux quantification model is developed, incorporating source–load carbon flow tracing and nonconvex carbon pricing dynamics to enhance environmental–economic co-optimization constraints. The spatiotemporally coupled multi-microgrid (MMG) coordination paradigm is reformulated as a continuous state-action Markov game process governed by stochastic differential Stackelberg game principles. A communication mechanism-enabled multi-agent twin-delayed deep deterministic policy gradient (CMMA-TD3) algorithm is implemented to achieve Pareto-optimal solutions through cyber–physical collaboration. Results of the measurements in the MMG containing three microgrids show that the proposed approach reduces operation costs by 61.59% and carbon emissions by 27.95% compared to the least effective benchmark solution.