Introduction: COVID-19 has been associated with increased risk of thrombosis, heparin resistance and coagulopathy in critically ill patients admitted to intensive care. We report the incidence of thrombotic and bleeding events in a single center cohort of 30 consecutive patients with COVID-19 supported by veno-venous extracorporeal oxygenation (ECMO) and who had a whole body Computed Tomography Scanner (CT) on admission. Methodology: All patients were initially admitted to other hospitals and later assessed and retrieved by our ECMO team. ECMO was initiated in the referral center and all patients admitted through our CT scan before settling in our intensive care unit. Clinical management was guided by our institutional ECMO guidelines, established since 2011 and applied to at least 40 patients every year. Results: We diagnosed a thrombotic event in 13 patients on the initial CT scan. Two of these 13 patients subsequently developed further thrombotic complications. Five of those 13 patients had a subsequent clinically significant major bleeding. In addition, two patients presented with isolated intracranial bleeds. Of the 11 patients who did not have baseline thrombotic events, one had a subsequent oropharyngeal hemorrhage. When analyzed by ROC analysis, the area under the curve for % time in intended anticoagulation range did not predict thrombosis or bleeding during the ECMO run (0.36 (95% CI 0.10–0.62); and 0.51 (95% CI 0.25–0.78); respectively). Conclusion: We observed a high prevalence of VTE and a significant number of hemorrhages in these severely ill patients with COVID-19 requiring veno-venous ECMO support.
Background Acute Type A aortic dissection (TAAD) is a life-threatening condition that carries significant mortality and morbidity; a proportion of the survivors might require further aortic procedures in the mid-/long-term follow-up. Quality of life (QoL) after TAAD is not well studied. Quality of life after Type A Aortic Dissection Surgery (QUADS) is the first multicentre study to assess QoL in survivors of surgically treated TAAD. Methods A tailored questionnaire for survivors of TAAD was designed with patient and public involvement. Patients who underwent surgery from 2018 to 2022 in eight United Kingdom centres were invited to participate. Preoperative, intraoperative, and postoperative prospectively collected data were collated and analyzed retrospectively. The data were analyzed with SPSS v29. Patient's questionnaire was validated with a Cronbach's alpha analysis, exploratory factor analysis, and AMOS confirmatory factor analysis. Three groups were created according to QoL (Good, Fair, Poor). Results A total of 162 patients were recruited. Majority were male with a mean age of 63 years (24–92). Surgical procedures for TAAD were root and ascending aorta replacement (n = 61, 38%), ascending (n = 81, 50%), and/or arch replacement (n = 20, 12%). Eleven patients (7%) required later intervention. Patient's answers regarding overall QoL were good (n = 67, 41%), fair (n = 89, 55%), and poor (n = 6, 4%). Neurological complications, circulatory arrest duration, reoperation for bleeding, postoperative myocardial infraction, arrhythmias, wound infection, and patient destination at discharge have been identified as main variables impacting on QoL after TAAD surgery across different domains of this questionnaire. Conclusion QUADS questionnaire is the first tailored and validated questionnaire for TAAD survivors. Results in the United Kingdom population suggest that it is a useful tool to assess QoL after TAAD surgery.
Background: Prosthesis patient mismatch (PPM) is associated with poor outcomes in literature. Prevention of mismatch is crucial in aortic valve replacement, yet there is no current consensus on preventative strategies. Objectives: This study introduces a novel clinical framework, nomenclature, and algorithm for contemporary Heart Team practice, providing a systematic approach for a tailored surgical strategy to anticipate and prevent mismatch. Methods: This was a single-center observational study performing a descriptive analysis of an evolving practice on 100 consecutive patients operated for aortic valve stenosis between 2020 and 2024. A step-by-step No-Mismatch algorithm was designed for the Heart Team to triage, discuss, and decide the surgical strategy prior to the procedure, identifying patients at risk of mismatch, and guiding the surgeon’s plan to prevent PPM and consider a Lifetime Valve Strategy. Results: The algorithm identified 26% of patients at risk of mismatch requiring a No-Mismatch strategy, and 20% at risk of small valve implantation requiring a Lifetime Valve Strategy. This cohort included 51 urgent cases. Valve pathology included 35% congenital, 59% degenerative, 1% rheumatic, and 5% redo operations. Valve implant type: 82% biological, including 29% rapid deployment valve (RDV), and 18% mechanical; 20% of patients required aortic root enlargements (AREs). Pre-, intra-, and post-operative data are presented. Mortality occurred at 1%. All degrees of mismatch were prevented. Conclusions: The surgeon was able to predict mismatch and elected either ARE, RDV, or a mechanical valve as required. Patient selection and a No-Mismatch Heart Team approach are essential to provide a tailored strategy for aortic valve interventions.
Background: Prosthesis patient mismatch (PPM) is associated with poor outcomes in literature. Prevention of mismatch is crucial in aortic valve replacement, yet there is no current consensus on preventative strategies. Objectives: This study introduces a novel clinical framework, nomenclature, and algorithm for contemporary Heart Team practice, providing a systematic approach for a tailored surgical strategy to anticipate and prevent mismatch. Methods: Single-centre observational study with descriptive analysis of an evolving practice on 100 consecutive patients operated for aortic valve stenosis between 2020 – 2024. A step-by-step No-Mismatch algorithm was designed for the Heart Team to triage, discuss and decide the surgical strategy prior to the procedure, identifying patients at risk of mismatch, and guiding the surgeon’s plan to prevent PPM and consider a lifetime valve strategy. Results: The algorithm identified 26% of patients at risk of mismatch requiring a No-Mismatch strategy, and 20% at risk of small valve implantation requiring a Lifetime Valve Strategy. This cohort included 51 urgent cases. Valve pathology included 35% congenital, 59% degenerative, 1% rheumatic, and 5% redo operations. Valve implant type: 82% biological, including 29% rapid deployment valve (RDV), 18% mechanical, and 20% of patients required aortic root enlargements (ARE). Pre, intra and post operative data presented. Mortality occurred at 1%. All degrees of mismatch were prevented. Conclusion:The surgeon was able to predict mismatch and elected either ARE, RDV, or a mechanical valve as required. Patient selection and a No-Mismatch Heart team approach are essential to provide a tailored strategy for aortic valve interventions.