James O'Neill

Dr. James O'Neill

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2022 in EP Europace
Verified
Journal Article
Open access
PDF file
PKPrapa Kanagaratnam
Prapa Kanagaratnam
JMJames McCready
James McCready
MTMuzahir Hassan Tayebjee
Muzahir Hassan Tayebjee
ESEwen Shepherd
Ewen Shepherd
TSThiagarajah Sasikaran
Thiagarajah Sasikaran
NPNeil Poulter
Neil Poulter
There is rising healthcare utilization related to the increasing incidence and prevalence of atrial fibrillation (AF) worldwide. Simplifying therapy and reducing hospital episodes would be a valuable development. The efficacy of a streamlined AF ablation approach was compared to drug therapy and a conventional catheter ablation technique for symptom control in paroxysmal AF. We recruited 321 patients with symptomatic paroxysmal AF to a prospective randomized, multi-centre, open label trial at 13 UK hospitals. Patients were randomized 1:1:1 to cryo-balloon ablation without electrical mapping with patients discharged same day [Ablation Versus Anti-arrhythmic Therapy for Reducing All Hospital Episodes from Recurrent (AVATAR) protocol]; optimization of drug therapy; or cryo-balloon ablation with confirmation of pulmonary vein isolation and overnight hospitalization. The primary endpoint was time to any hospital episode related to treatment for atrial arrhythmia. Secondary endpoints included complications of treatment and quality-of-life measures. The hazard ratio (HR) for a primary endpoint event occurring when comparing AVATAR protocol arm to drug therapy was 0.156 (95% CI, 0.097–0.250; P < 0.0001 by Cox regression). Twenty-three patients (21%) recorded an endpoint event in the AVATAR arm compared to 76 patients (74%) within the drug therapy arm. Comparing AVATAR and conventional ablation arms resulted in a non-significant HR of 1.173 (95% CI, 0.639–2.154; P = 0.61 by Cox regression) with 23 patients (21%) and 19 patients (18%), respectively, recording primary endpoint events (P = 0.61 by log-rank test). The AVATAR protocol was superior to drug therapy for avoiding hospital episodes related to AF treatment, but conventional cryoablation was not superior to the AVATAR protocol. This could have wide-ranging implications on how demand for AF symptom control is met. Clinical Trials Registration: NCT02459574.

21 October 2018 in Clinical Cardiology
Verified
Journal Article
Open access
PDF file
JOJames O'Neill
James O'Neill
PSPeter Swoboda
Peter Swoboda
SPSven Plein
Sven Plein
MTMuzahir H Tayebjee
Muzahir H Tayebjee
Background: South Asians have a low prevalence of atrial fibrillation (AF) compared with Caucasians despite having a higher prevalence of conventional risk factors for the arrhythmia. The reason for this disparity is uncertain but may be due to ethnic differences in atrial morphology. This study examines the association between ethnicity and left atrial (LA) size and function in South Asian and Caucasian subjects using the reference technique of cardiovascular magnetic resonance imaging (MRI).Hypothesis: South Asians have smaller LA size and therefore increased LA function.Methods: Retrospective case‐control study of 60 South Asian and 60 Caucasian patients who had undergone a clinically indicated MRI between April 2010 and October 2017 and had been found to have a structurally normal heart. LA and left ventricular (LV) volume and function were assessed and compared between the ethnicities.Results: In comparison with Caucasians, South Asians had significantly lower minimum (27.7 ± 11.1 mL vs 34.9 ± 12.3 mL, P = 0.002) and maximum LA volumes (64.7 ± 21.1 mL vs 80.9 ± 22.5 mL, P < 0.001), lower LV end‐diastolic volume (P < 0.001), lower LV stroke volume (P < 0.001), and lower LV mass (P = 0.022) and these values remained significant after correcting for body surface area. Further analysis revealed that LA volume was independently associated with South Asian ethnicity. There was no difference in LA function between the ethnic groups.Conclusions: South Asians have reduced LA volumes and a proportionally smaller heart size in comparison to Caucasians. Smaller LA size may protect against the development of AF by reducing the risk of reentrant circuit formation and atrial fibrosis development.

23 August 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JOJames O'Neill
James O'Neill
KBKatrina Bounford
Katrina Bounford
AAAlice Anstey
Alice Anstey
JDJesvita D’sIlva
Jesvita D’sIlva
LCLisa Clark
Lisa Clark
MTMuzahir H. Tayebjee
Muzahir H. Tayebjee
South Asians have a low prevalence of atrial fibrillation (AF) in comparison with White Europeans despite a higher burden of hypertension, diabetes mellitus and coronary artery disease. The reason for this disparity is unclear but may relate to electrophysiological or structural differences within the atria or variations in autonomic function. We aimed to assess these areas using a range of non-invasive cardiac investigations. A prospective cohort study was performed on 200 South Asian and 200 Caucasian healthy volunteers aged 18–40 years. All subjects underwent electrocardiography (ECG), echocardiography and anthropometric measurements. Eighty subjects in each cohort underwent 24 hour ambulatory ECG and fifty subjects in each cohort underwent exercise testing. Compared with White Europeans, South Asians were of a smaller height with lower lean body mass and smaller left atrial size. They had reduced P wave dispersion and P wave terminal force in lead V1. South Asians had a lower burden of supraventricular ectopy. They had a higher mean heart rate and South Asian males had lower heart rate variability, suggestive of sympathetic predominance. Exercise capacity was lower in South Asians. South Asians have differences in left atrial size, P wave indices, burden of supraventricular ectopy, heart rate, heart rate variability and anthropometric measurements. These differences may relate to variations in atrial morphology, atrial electrophysiology and autonomic function and might help to explain why South Asians are less susceptible to developing AF.

29 September 2018 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
JOJames O'Neill
James O'Neill
LJLina Jegodzinski
Lina Jegodzinski
MTMuzahir H. Tayebjee
Muzahir H. Tayebjee

16 October 2017 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
JOJames O'Neill
James O'Neill
AHAndrew J. Hogarth
Andrew J. Hogarth
IPIan Pearson
Ian Pearson
HLHannah Law
Hannah Law
RBRobert Bowes
Robert Bowes
MTMuzahir H. Tayebjee
Muzahir H. Tayebjee

3 April 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
GBGordon A. Begg
Gordon A. Begg
JOJames O'Neill
James O'Neill
ASAfzal Sohaib
Afzal Sohaib
AMAilsa McLean
Ailsa McLean
CPChris B. Pepper
Chris B. Pepper
MTMuzahir Hassan Tayebjee
Muzahir Hassan Tayebjee
Electrical coupling index (ECI) and contact force (CF) have been developed to aid lesion formation during catheter ablation. ECI measures tissue impedance and capacitance whilst CF measures direct contact. The aim was to determine whether the presence of catheter / tissue interaction information, such as ECI and CF, reduce time to achieve bidirectional cavotricuspid isthmus block during atrial flutter (AFL) ablation. Patients with paroxysmal or persistent AFL were randomised to CF visible (range 5-40g), CF not visible, ECI visible (change of 12%) or ECI not visible. Follow-up occurred at 3 and 6 months and included a 7 day ECG recording. The primary endpoint was time to bidirectional cavotricuspid isthmus block. 114 patients were randomised, 16 were excluded. Time to bidirectional block was significantly shorter when ECI was visible (median 30.0 mins (IQR 31) to median 10.5mins (IQR 12) p 0.023) versus ECI not visible. There was a trend towards a shorter time to bidirectional block when CF was visible. Higher force was applied when CF was visible (median 9.03g (IQR 7.4) vs. 11.3g (5.5) p 0.017). There was no difference in the acute recurrence of conduction between groups. The complication rate was 2%, AFL recurrence was 1.1% and at 6 month follow-up, 12% had atrial fibrillation. The use of tissue contact information during AFL ablation was associated with reduced time taken to achieve bidirectional block when ECI was visible. Contact force data improved contact when visible with a trend towards a reduction in the procedural endpoint. ClinicalTrials.gov trial identifier: NCT02490033.