Dwaipayan Biswas

Dr. Dwaipayan Biswas

Interuniversity Micro-Electronics Center, Leuven, Belgium

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2019 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
Dwaipayan BiswasDwaipayan Biswas
Dwaipayan Biswas
LELuke Everson
Luke Everson
MLMuqing Liu
Muqing Liu
MPMadhuri Panwar
Madhuri Panwar
BVBram-Ernst Verhoef
Bram-Ernst Verhoef
NHNick Van Helleputte
Nick Van Helleputte
Advancements in wireless sensor network technologies have enabled the proliferation of miniaturized body-worn sensors, capable of long-term pervasive biomedical signal monitoring. Remote cardiovascular monitoring has been one of the beneficiaries of this development, resulting in non-invasive, photoplethysmography (PPG) sensors being used in ambulatory settings. Wrist-worn PPG, although a popular alternative to electrocardiogram, suffers from motion artifacts inherent in daily life. Hence, in this paper, we present a novel deep learning framework (CorNET) to efficiently estimate heart rate (HR) information and perform biometric identification (BId) using only a wrist-worn, single-channel PPG signal collected in ambulant environment. We have formulated a completely personalized data-driven approach, using a four-layer deep neural network. Two convolution neural network layers are used in conjunction with two long short-term memory layers, followed by a dense output layer for modeling the temporal sequence inherent within the pulsatile signal representative of cardiac activity. The final dense layer is customized with respect to the application, functioning as: regression layer-having a single neuron to predict HR; classification layer-two neurons that identify a subject among a group. The proposed network was evaluated on the TROIKA dataset having 22 PPG records collected during various physical activities. We achieve a mean absolute error of 1.47 ± 3.37 beats per minute for HR estimation and an average accuracy of 96% for BId on 20 subjects. CorNET was further evaluated successfully in an ambulant use-case scenario with custom sensors for two subjects.

1 May 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Dwaipayan BiswasDwaipayan Biswas
Dwaipayan Biswas
NSNeide Simoes-Capela
Neide Simoes-Capela
CHChris Van Hoof
Chris Van Hoof
NHNick Van Helleputte
Nick Van Helleputte
Photoplethysmography (PPG) is a low-cost, non-invasive, optical technique used to detect blood volume changes in the microvascular tissue bed, measured from the skin surface. It has traditionally been used in commercial medical devices for oxygen saturation, blood pressure monitoring and cardiac activity for assessing peripheral vascular disease and autonomic function. There has been a growing interest to incorporate PPG sensors in daily life, capable of use in ambulatory settings. However, inferring cardiac information (e.g. heart rate) from PPG traces in such situations is extremely challenging, because of interferences caused by motion. Following the IEEE Signal Processing Cup in 2015, numerous methods have been proposed for estimating particularly the average heart rate using wrist-worn PPG during physical activity. Details on PPG technology, sensor development and applications have been well documented in literature. Hence, in this paper, we have presented a comprehensive review of state-of-the-art research on heart rate estimation from wrist-worn photoplethysmography (PPG) signals. Our review also encompasses brief theoretical details about PPG sensing and other potential applications – biometric identification, disease diagnosis using wrist PPG. This article will set a platform for future research on pervasive monitoring using wrist PP.G.

30 April 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MPMadhuri Panwar
Madhuri Panwar
AGArvind Gautam
Arvind Gautam
Dwaipayan BiswasDwaipayan Biswas
Dwaipayan Biswas
AAAmit Acharyya
Amit Acharyya
This paper presents a deep learning model ‘PP-Net’ which is the first of its kind, having the capability to estimate the physiological parameters: Diastolic blood pressure (DBP), Systolic blood pressure (SBP), and Heart rate (HR) simultaneously from the same network using a single channel PPG signal. The proposed model is designed by exploiting the deep learning framework of Long-term Recurrent Convolutional Network (LRCN), exhibiting inherent ability of feature extraction, thereby, eliminating the cost effective steps of feature selection and extraction, making less-complex for deployment on resource constrained platforms such as mobile platforms. The performance demonstration of the PP-Net is done on a larger and publically available MIMIC-II database. We achieved an average NMAE of 0.09 (DBP) and 0.04 (SBP) mmHg for BP, and 0.046 bpm for HR estimation on total population of 1557 critically ill subjects. The accurate estimation of HR and BP on a larger population compared to the existing methods, demonstrated the effectiveness of our proposed deep learning framework. The accurate evaluation on a huge population with CVD complications, validates the robustness of the proposed framework in pervasive healthcare monitoring especially cardiac and stroke rehabilitation monitoring.

18 February 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MPMadhuri Panwar
Madhuri Panwar
Dwaipayan BiswasDwaipayan Biswas
Dwaipayan Biswas
HBHarsh Bajaj
Harsh Bajaj
MJMichael Jobges
Michael Jobges
RTRuth Turk
Ruth Turk
AAAmit Acharyya
Amit Acharyya
In this paper, we present a deep learning framework ‘Rehab-Net’ for effectively classifying three upper limb movements of the human arm, involving extension, flexion and rotation of the forearm which over the time could provide a measure of rehabilitation progress. The proposed framework, Rehab-Net is formulated with a personalized, light weight and low complex, customized CNN model, using 2-layers of Convolutional neural network (CNN), interleaved with pooling layers, followed by a fully-connected layer that classifies the three movements from tri-axial acceleration input data collected from the wrist. The proposed Rehab-net framework was validated on sensor data collected in two situations-a) seminaturalistic environment involving an archetypal activity of ‘making-tea’ with 4 stroke survivors and b) natural environment, where 10 stroke survivors were free to perform any desired arm movement for a duration of 120 minutes. We achieve an overall accuracy of 97.89% on semi-naturalistic data and 88.87% on naturalistic data which exceeded state-of-the-art learning algorithms namely, Linear Discriminant Analysis, Support Vector Machines, and k-means clustering with an average accuracy of 48.89%, 44.14% and 27.64%. Subsequently, a computational complexity analysis of the proposed model has been discussed with an eye towards hardware implementation. The clinical significance of this study is to accurately monitor the clinical progress of the rehabilitated subjects under the ambulatory settings.

1 March 2013 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
EMEvangelos Mazomenos
Evangelos Mazomenos
Dwaipayan BiswasDwaipayan Biswas
Dwaipayan Biswas
AAA. Acharyya
A. Acharyya
TCTaihai Chen
Taihai Chen
KMK. Maharatna
K. Maharatna
NCN. Curzen
N. Curzen
This paper introduces a low-complexity algorithm for the extraction of the fiducial points from the electrocardiogram (ECG). The application area we consider is that of remote cardiovascular monitoring, where continuous sensing and processing takes place in low-power, computationally constrained devices, thus the power consumption and complexity of the processing algorithms should remain at a minimum level. Under this context, we choose to employ the discrete wavelet transform (DWT) with the Haar function being the mother wavelet, as our principal analysis method. From the modulus-maxima analysis on the DWT coefficients, an approximation of the ECG fiducial points is extracted. These initial findings are complimented with a refinement stage, based on the time-domain morphological properties of the ECG, which alleviates the decreased temporal resolution of the DWT. The resulting algorithm is a hybrid scheme of time- and frequency-domain signal processing. Feature extraction results from 27 ECG signals from QTDB were tested against manual annotations and used to compare our approach against the state-of-the art ECG delineators. In addition, 450 signals from the 15-lead PTBDB are used to evaluate the obtained performance against the CSE tolerance limits. Our findings indicate that all but one CSE limits are satisfied. This level of performance combined with a complexity analysis, where the upper bound of the proposed algorithm, in terms of arithmetic operations, is calculated as 2.423 N +214 additions and 1.093 N +12 multiplications for N ≤ 861 or 2.553 N +102 additions and 1.093 N +10 multiplications for N > 861 ( N being the number of input samples), reveals that the proposed method achieves an ideal tradeoff between computational complexity and performance, a key requirement in remote cardiovascular disease monitoring systems.

7 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
YZYifan Zhang
Yifan Zhang
Shuang SongShuang Song
Shuang Song
RVRik Vullings
Rik Vullings
Dwaipayan BiswasDwaipayan Biswas
Dwaipayan Biswas
NNeide Simões-Capela
Neide Simões-Capela
WGWillemijn Groenendaal
Willemijn Groenendaal
Long-term heart rate (HR) monitoring by wrist-worn photoplethysmograph (PPG) sensors enables the assessment of health conditions during daily life with high user comfort. However, PPG signals are vulnerable to motion artifacts (MAs), which significantly affect the accuracy of estimated physiological parameters such as HR. This paper proposes a novel modular algorithm framework for MA removal based on different wavelengths for wrist-worn PPG sensors. The framework uses a green PPG signal for HR monitoring and an infrared PPG signal as the motion reference. The proposed framework includes four main steps: motion detection, motion removal using continuous wavelet transform, approximate HR estimation and signal reconstruction. The proposed algorithm is evaluated against an electrocardiogram (ECG) in terms of HR error for a dataset of 6 healthy subjects performing 21 types of motion. The proposed MA removal method reduced the average error in HR estimation from 4.3, 3.0 and 3.8 bpm to 0.6, 1.0 and 2.1 bpm in periodic, random, and continuous non-periodic motion situations, respectively.