Many of the intriguing properties of blood originate from its cellular nature. Therefore, accurate modelling of blood flow related phenomena requires a description of the dynamics at the level of individual cells. This, however, presents several computational challenges that can only be addressed by high performance computing. We present Hemocell, a parallel computing framework which implements validated mechanical models for red blood cells and is capable of reproducing the emergent transport characteristics of such a complex cellular system. It is computationally capable of handling large domain sizes, thus it is able to bridge the cell-based micro-scale and macroscopic domains. We introduce a new material model for resolving the mechanical responses of red blood cell membranes under various flow conditions and compare it with a well established model. Our new constitutive model has similar accuracy under relaxed flow conditions, however, it performs better for shear rates over 1500 1/s. We also introduce a new method to generate randomised initial conditions for dense mixtures of different cell types free of initial positioning artefacts.
The influence of red blood cell (RBC) deformability in whole blood on platelet margination is investigated using confocal microscopy measurements of flowing human blood and cell resolved blood flow simulations. Fluorescent platelet concentrations at the wall of a glass chamber are measured using confocal microscopy with flowing human blood containing varying healthy-to-stiff RBC fractions. A decrease is observed in the fluorescent platelet signal at the wall due to the increase of stiffened RBCs in flow, suggesting a decrease of platelet margination due to an increased fraction of stiffened RBCs present in the flow. In order to resolve the influence of stiffened RBCs on platelet concentration at the channel wall, cell-pair and bulk flow simulations are performed. For homogeneous collisions between RBC pairs, a decrease in final displacement after a collision with increasing membrane stiffness is observed. In heterogeneous collisions between healthy and stiff RBC pairs, it is found that the stiffened RBC is displaced most. The influence of RBC deformability on collisions between RBCs and platelets was found to be negligible due to their size and mass difference. For a straight vessel geometry with varying healthy-to-stiff RBC ratios, a decrease was observed in the red blood cell-free layer and platelet margination due to an increase in stiffened RBCs present in flow. The primary function of the human red blood cell is to deliver oxygen to the tissues of the body. The ability of the red blood cell to deform allows it to squeeze through small capillaries along with helping transport platelets to damaged areas on the vessel wall, which initiates normal coagulation function. Many diseases are known to impede the deformability of the red blood cell, which may adversely impact the transport of red blood cells and platelets in flow. We observe that with increasing fractions of stiff red blood cells in flow, there is a decrease of platelet margination. Specifically, this is observed as a decrease of the fluorescent platelet signal at the wall of a glass channel with flowing whole blood. We confirm this margination decrease by performing cell resolved simulations that reproduce the experiments. We also observe, in simulation, a decrease in the red blood cell-free layer as red blood cell deformability decreases. The decrease in the cell-free layer, we believe, is the most significant contributing factor to decreased margination.
The radial distribution of cells in blood flow inside vessels is highly non-homogeneous. This leads to numerous important properties of blood, yet the mechanisms shaping these distributions are not fully understood. The motion of cells is governed by a variety of hydrodynamic interactions and cell-deformation mechanics. Properties, such as the effective cell diffusivity, are therefore difficult to investigate in flows other than pure shear flows. In this work, several single-cell, cell-pair, and large-scale many-cell simulations are performed using a validated numerical model. Apart from the single-cell mechanical validations, the arising flow profile, cell free layer widths, and cell drift velocities are compared to previous experimental findings. The motion of the cells at various radial positions and under different flow conditions is extracted, and evaluated through a statistical approach. An extended diffusive flux-type model is introduced which describes the cell diffusivities under a wide range of flow conditions and incorporates the effects of cell deformability through a shear dependent description of the cell collision cross sections. This model is applicable for both red blood cells and platelets. Further evaluation of particle trajectories shows that the margination of platelets cannot be the net result of gradients in diffusivity. However, the margination mechanism is strongly linked to the gradient of the hematocrit level. Finally, it shows that platelets marginate only until the edge of the red blood cell distribution and they do not fill the cell free layer.
Blood flow is a major regulator of hemostasis and arterial thrombosis. The current view is that low and intermediate flows occur in intact healthy vessels, whereas high shear levels (>2000 s−1) are reached in stenosed arteries, notably during thrombosis. To date, the shear rates occurring at the edge of a lesion in an otherwise healthy vessel are nevertheless unknown. The aim of this work was to measure the shear rates prevailing in wounds in a context relevant to hemostasis. Three models of vessel puncture and transection were developed and characterized for a study that was implemented in mice and humans. Doppler probe measurements supplemented by a computational model revealed that shear rates at the edge of a wound reached high values, with medians of 22 000 s−1, 25 000 s−1, and 7000 s−1 after puncture of the murine carotid artery, aorta, or saphenous vein, respectively. Similar shear levels were observed after transection of the mouse spermatic artery. These results were confirmed in a human venous puncture model, where shear rates in a catheter implanted in the cubital vein reached 2000 to 27 000 s−1. In all models, the high shear conditions were accompanied by elevated levels of elongational flow exceeding 1000 s−1. In the puncture model, the shear rates decreased steeply with increasing injury size. This phenomenon could be explained by the low hydrodynamic resistance of the injuries as compared with that of the downstream vessel network. These findings show that high shear rates (>3000 s−1) are relevant to hemostasis and not exclusive to arterial thrombosis.
In-silico cellular models of blood are invaluable to gain understanding about the many interesting properties that blood exhibits. However, numerical investigations that focus on the effects of cytoplasmic viscosity in these models are not very prevalent. We present a parallelised method to implement cytoplasmic viscosity for HemoCell, an open-source cellular model based on immersed boundary lattice Boltzmann methods, using an efficient ray-casting algorithm. The effects of the implementation are investigated with single-cell simulations focusing on the deformation in shear flow, the migration due to wall induced lift forces, the characteristic response time in periodic stretching and pair collisions between red blood cells and platelets. Collective transport phenomena are also investigated in many-cell simulations in a pressure driven channel flow. The simulations indicate that the addition of a viscosity contrast between internal and external fluids significantly affects the deformability of a red blood cell, which is most pronounced during very short time-scale events. Therefore, modelling the cytoplasmic viscosity contrast is important in scenarios with high velocity deformation, typically high shear rate flows.
The influence of the flow environment on platelet aggregation is not fully understood in high-shear thrombosis. The objective of this study is to investigate the role of a high shear rate in initial platelet aggregation. The haemodynamic conditions in a microfluidic device are studied using cell-based blood flow simulations. The results are compared with in vitro platelet aggregation experiments performed with porcine whole blood (WB) and platelet-rich-plasma (PRP). We studied whether the cell-depleted layer in combination with high shear and high platelet flux can account for the distribution of platelet aggregates. High platelet fluxes at the wall were found in silico. In WB, the platelet flux was about twice as high as in PRP. Additionally, initial platelet aggregation and occlusion were observed in vitro in the stenotic region. In PRP, the position of the occlusive thrombus was located more downstream than in WB. Furthermore, the shear rates and stresses in cell-based and continuum simulations were studied. We found that a continuum simulation is a good approximation for PRP. For WB, it cannot predict the correct values near the wall.