Hwaseong Ryu

Dr. Hwaseong Ryu

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
HKHyo-Jin Kang
Hyo-Jin Kang
SLSang Min Lee
Sang Min Lee
SJSun Kyung Jeon
Sun Kyung Jeon
HRHwaseong Ryu
Hwaseong Ryu
JYJeongin Yoo
Jeongin Yoo
JHJoon Koo Han
Joon Koo Han
Kang HJ, et al. Korean J Radiol. 2019 Jul;20(7):1114-1123. https://doi.org/10.3348/kjr.2018.0932

1 January 2022 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
Hyo Jung ParkHyo Jung Park
Hyo Jung Park
JYJee Seok Yoon
Jee Seok Yoon
SLSeung Soo Lee
Seung Soo Lee
HSHeung-Il Suk
Heung-Il Suk
BPBumwoo Park
Bumwoo Park
HRHwaseong Ryu
Hwaseong Ryu
Park HJ, et al. Korean J Radiol. 2022 Jul;23(7):720-731. https://doi.org/10.3348/kjr.2021.0892

1 July 2019 in Ultrasonography
Verified
Journal Article
Open access
PDF file
HRHwaseong Ryu
Hwaseong Ryu
SASu Joa Ahn
Su Joa Ahn
JYJeong Hee Yoon
Jeong Hee Yoon
SLSang Min Lee
Sang Min Lee
The purpose of this study was to retrospectively compare the technical success and reliability of the measurements made using two 2-dimensional (2D) shear wave elastography (SWE) systems using the comb-push technique from the same manufacturer and to assess the intersystem reproducibility of the resultant liver stiffness (LS) measurements. Ninety-four patients with suspected chronic liver diseases were included in this retrospective study. LS measurements were obtained using two 2D-SWE systems (LOGIQ E9 and LOGIQ S8) from the same manufacturer, with transient elastography (TE) serving as the reference standard, on the same day. The technical success rates and reliability of the measurements of the two 2D-SWE systems were compared. LS values measured using the two 2D-SWE systems and TE were correlated using Spearman correlation coefficients and 95% Bland-Altman limits of agreement. Thereafter, Bland-Altman limits of agreement and intraclass correlation coefficients (ICCs) were used to analyze the intersystem reproducibility of LS measurements. The two 2D-SWE systems showed similar technical success rates (98.9% for both) and reliability of LS measurements (92.3% for the LOGIQ E9, 91.2% for the LOGIQ S8; P=0.185). Despite the excellent correlation (ICC=0.92), the mean LS measurements obtained by the two 2D-SWE systems were significantly different (LOGIQ E9, 6.57±2.33 kPa; LOGIQ S8, 6.90±6.64 kPa; P=0.018). Significant intersystem variability was observed in the LS measurements made using the two 2D-SWE systems. Therefore, even 2D-SWE systems from the same manufacturer should not be used interchangeably in longitudinal follow-up.

1 October 2019 in Ultrasonography
Verified
Journal Article
Open access
PDF file
HRHwaseong Ryu
Hwaseong Ryu
SASu Joa Ahn
Su Joa Ahn
JYJeong Hee Yoon
Jeong Hee Yoon
SLSang Min Lee
Sang Min Lee
Purpose: The purpose of this study was to compare the technical success rate and reliability of measurements made using three shear wave elastography (SWE) techniques and to assess the inter-platform reproducibility of the resultant liver stiffness measurements. Methods: This prospective study included 54 patients with liver disease. Liver stiffness (LS) measurements were obtained using 2-point SWE techniques (Virtual Touch Quantification and S-Shearwave) and 2-dimensional (2D) SWE, with transient elastography (TE) serving as the reference standard. The technical success rates and measurement reliability of the three techniques were compared. LS values measured using the three SWE techniques and TE were compared using Spearman correlation coefficients and 95% Bland-Altman limits of agreement. Intra-class correlation coefficients (ICC) were used to analyze the inter-platform reproducibility of LS measurements. Results: The three SWE techniques and TE showed similar technical success rates (P=0.682) but demonstrated significant differences in the reliability of LS measurements (P=0.006) and mean LS measurements (P<0.001). Despite strong correlations (r=0.73-0.94) between SWE systems, various degrees of inter-platform reproducibility (ICC, 0.58-0.92) were observed for the three SWE techniques. The best agreement was observed between S-Shearwave and TE (ICC, 0.92), and the worst agreement was observed between 2D-SWE and TE (ICC, 0.58). In the Bland-Altman analysis, a tendency toward lower LS values with the three SWE techniques than with TE in patients with F3 and F4 disease was observed. Conclusion: Significant inter-system variability was observed in LS measurements made using the three SWE techniques. Therefore, LS values measured using different SWE techniques should not be used interchangeably for longitudinal follow-up.

1 July 2020 in Ultrasonography
Verified
Journal Article
Open access
PDF file
SCSeo-Youn Choi
Seo-Youn Choi
JKJung Hoon Kim
Jung Hoon Kim
HEHyo Won Eun
Hyo Won Eun
HRHwaseong Ryu
Hwaseong Ryu
This study was conducted to determine which factors influence the ability of abdominal ultrasonography (US) to detect focal pancreatic lesions identified using endoscopic ultrasonography (EUS). In this study, 338 consecutive patients with focal pancreatic lesions (cyst, n=253; adenocarcinoma, n=54; pancreatic neuroendocrine tumor, n=24; solid pseudopapillary neoplasm, n=4; intrapancreatic accessory spleen, n=1; metastasis, n=1; and lymphoma, n=1) detected by EUS who underwent US were enrolled. We reviewed their radiologic reports and assessed the presence or absence of a focal lesion, the multiplicity of the lesions, and their size and location on US. We evaluated how these parameters differed depending on whether the lesion was solid or cystic. Univariate and multivariate logistic regression analysis were performed. The overall detection rate of focal pancreatic lesions by US was 61.5% (208 of 338). Using US, the detection rate of cystic lesions was 58.5% (148 of 253), while that of solid lesions was 70.6% (60 of 85). In the univariate analysis, location in the neck or body, solid characteristics, and a relatively large size (15.50±10.08 mm vs. 23.09±12.93 mm) were associated with a significantly higher detection rate (P<0.001, P=0.047, and P<0.001, respectively). In the multivariate analysis, location in the neck or body (odds ratio [OR], 3.238; 95% confidence interval [CI], 1.926 to 5.443; P<0.001) and size (OR, 1.070; 95% CI, 1.044 to 1.096; P<0.001) were proven to be significant predictors of detectability (P<0.001). US is useful for detecting focal pancreatic lesions, especially when they are located in the neck or body and are relatively large.

1 January 2025 in Investigative and Clinical Urology
Verified
Journal Article
Open access
PDF file
WSWon Hoon Song
Won Hoon Song
TKTae Un Kim
Tae Un Kim
HRHwaseong Ryu
Hwaseong Ryu
MYMi Sook Yun
Mi Sook Yun
SPSung-Woo Park
Sung-Woo Park
Song WH, et al. Investig Clin Urol. 2025 Sep;66(5):405-415. https://doi.org/10.4111/icu.20250208