Tsolmon Khalzan

Mrs. Tsolmon Khalzan

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2026 in Energies
Verified
Journal Article
Open access
PDF file
TKTsolmon Khalzan
Tsolmon Khalzan
BSBatmunkh Sereeter
Batmunkh Sereeter
Ulaanbaatar, the capital of Mongolia, operates one of the world’s largest district heating (DH) systems in the coldest national capital (heating degree-days ~5800). Despite serving over 60% of the city’s 1.6 million residents, the current 3rd generation DH system suffers from high thermal losses (~17–18%) and relies on coal-fired combined heat and power plants. Transitioning to 4th generation district heating (4GDH) with lower supply temperatures could reduce these losses while enabling future low-temperature renewable energy integration. A geographic information system (GIS)-based spatial heat load density (HLD) analysis uses operational data from the Ulaanbaatar District Heating Company, encompassing 13,500 buildings with a total connected capacity of 3924 MW. Grid-based spatial analysis was performed at two resolutions (1 km2 and 2 km2). Threshold sensitivity analysis was conducted across HLD criteria of 1–5 MW/km2. Results indicate that median HLD values exceed the European reference threshold of 3 MW/km2, with log-normal distributions confirmed by Shapiro–Wilk tests. Three candidate pilot zones were identified. A hybrid temperature strategy (65/35 °C above −25 °C; 90/60 °C below) further contextualizes the findings. These results suggest spatially favorable conditions for 4GDH development, providing a quantitative foundation for subsequent techno-economic feasibility studies.

13 February 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
TKTsolmon Khalzan
Tsolmon Khalzan
BLBatmend Luvsandorj
Batmend Luvsandorj
BSBatmunkh Sereeter
Batmunkh Sereeter
Ulaanbaatar, the capital of Mongolia, operates one of the world’s largest district heating (DH) systems in the coldest national capital (Heating Degree Days ~5800). Despite serving over 60% of the city’s 1.6 million residents, the current 3rd generation DH system suffers from high thermal losses (~17–18%) and relies on coal-fired combined heat and power plants. Transitioning to 4th generation district heating (4GDH) with lower supply temperatures could reduce these losses while enabling future low-temperature renewable energy integration. This GIS-based spatial heat load density (HLD) analysis uses operational data from the Ulaanbaatar District Heating Company, encompassing 13,500 buildings with a total connected capacity of 3,924 MW. Grid-based spatial analysis was performed at two resolutions (1 km² and 2 km²). Threshold sensitivity analysis was conducted across HLD criteria of 1–5 MW/km². Results indicate that median HLD values exceed the European reference threshold of 3 MW/km², with log-normal distributions confirmed by Shapiro–Wilk tests. Three candidate pilot zones were identified. A hybrid temperature strategy (65/35 °C above −25 °C; 90/60 °C below) further contextualizes the findings. These results suggest spatially favorable conditions for 4GDH development, providing a quantitative foundation for subsequent techno-economic feasibility studies.