Stephen Saddow

Dr. Stephen Saddow

University of South Florida

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2013 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
AOAlexandra Oliveros
Alexandra Oliveros
Anthony Guiseppi-ElieAnthony Guiseppi-Elie
Anthony Guiseppi-Elie
Stephen Edward  SaddowStephen Edward Saddow
Stephen Edward Saddow

6 June 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
Francesco La ViaFrancesco La Via
Francesco La Via
DADaniel Alquier
Daniel Alquier
Filippo GiannazzoFilippo Giannazzo
Filippo Giannazzo
TKTsunenobu Kimoto
Tsunenobu Kimoto
PNPhilip Neudeck
Philip Neudeck
Salvatore TudiscoSalvatore Tudisco
Salvatore Tudisco
In recent years, several new applications of SiC (both 4H and 3C polytypes) have been proposed in different papers. In this review, several of these emerging applications have been reported to show the development status, the main problems to be solved and the outlooks for these new devices. The use of SiC for high temperature applications in space, high temperature CMOS, high radiation hard detectors, new optical devices, high frequency MEMS, new devices with integrated 2D materials and biosensors have been extensively reviewed in this paper. The development of these new applications, at least for the 4H-SiC ones, has been favored by the strong improvement in SiC technology and in the material quality and price, due to the increasing market for power devices. However, at the same time, these new applications need the development of new processes and the improvement of material properties (high temperature packages, channel mobility and threshold voltage instability improvement, thick epitaxial layers, low defects, long carrier lifetime, low epitaxial doping). Instead, in the case of 3C-SiC applications, several new projects have developed material processes to obtain more performing MEMS, photonics and biomedical devices. Despite the good performance of these devices and the potential market, the further development of the material and of the specific processes and the lack of several SiC foundries for these applications are limiting further development in these fields.

22 February 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
Stephen Edward  SaddowStephen Edward Saddow
Stephen Edward Saddow
Silicon carbide (SiC) is a highly robust semiconductor material that has the potential to revolutionize implantable medical devices for human healthcare, such as biosensors and neuro-implants, to enable advanced biomedical therapeutic applications for humans. SiC is both bio and hemocompatible, and is already commercially used for long-term human in vivo applications ranging from heart stent coatings and dental implants to short-term diagnostic applications involving neural implants and sensors. One challenge facing the medical community today is the lack of biocompatible materials which are inherently smart or, in other words, capable of electronic functionality. Such devices are currently implemented using silicon technology, which either has to be hermetically sealed so it does not directly interact with biological tissue or has a short lifetime due to instabilities in vivo. Long-term, permanently implanted devices such as glucose sensors, neural interfaces, smart bone and organ implants, etc., require a more robust material that does not degrade over time and is not recognized and rejected as a foreign object by the inflammatory response. SiC has displayed these exceptional material properties, which opens up a whole new host of applications and allows for the development of many advanced biomedical devices never before possible for long-term use in vivo. This paper is a review of the state-of-the art and discusses cutting-edge device applications where SiC medical devices are poised to translate to the commercial marketplace.

29 June 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
MBMohammad Beygi
Mohammad Beygi
JBJohn Bentley
John Bentley
CFChristopher L. Frewin
Christopher L. Frewin
CKCary A. Kuliasha
Cary A. Kuliasha
ATArash Takshi
Arash Takshi
Stephen Edward  SaddowStephen Edward Saddow
Stephen Edward Saddow
One of the main issues with micron-sized intracortical neural interfaces (INIs) is their long-term reliability, with one major factor stemming from the material failure caused by the heterogeneous integration of multiple materials used to realize the implant. Single crystalline cubic silicon carbide (3C-SiC) is a semiconductor material that has been long recognized for its mechanical robustness and chemical inertness. It has the benefit of demonstrated biocompatibility, which makes it a promising candidate for chronically-stable, implantable INIs. Here, we report on the fabrication and initial electrochemical characterization of a nearly monolithic, Michigan-style 3C-SiC microelectrode array (MEA) probe. The probe consists of a single 5 mm-long shank with 16 electrode sites. An ~8 µm-thick p-type 3C-SiC epilayer was grown on a silicon-on-insulator (SOI) wafer, which was followed by a ~2 µm-thick epilayer of heavily n-type (n+) 3C-SiC in order to form conductive traces and the electrode sites. Diodes formed between the p and n+ layers provided substrate isolation between the channels. A thin layer of amorphous silicon carbide (a-SiC) was deposited via plasma-enhanced chemical vapor deposition (PECVD) to insulate the surface of the probe from the external environment. Forming the probes on a SOI wafer supported the ease of probe removal from the handle wafer by simple immersion in HF, thus aiding in the manufacturability of the probes. Free-standing probes and planar single-ended test microelectrodes were fabricated from the same 3C-SiC epiwafers. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were performed on test microelectrodes with an area of 491 µm2 in phosphate buffered saline (PBS) solution. The measurements showed an impedance magnitude of 165 kΩ ± 14.7 kΩ (mean ± standard deviation) at 1 kHz, anodic charge storage capacity (CSC) of 15.4 ± 1.46 mC/cm2, and a cathodic CSC of 15.2 ± 1.03 mC/cm2. Current-voltage tests were conducted to characterize the p-n diode, n-p-n junction isolation, and leakage currents. The turn-on voltage was determined to be on the order of ~1.4 V and the leakage current was less than 8 μArms. This all-SiC neural probe realizes nearly monolithic integration of device components to provide a likely neurocompatible INI that should mitigate long-term reliability issues associated with chronic implantation.

27 April 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
TMTiffany C. Miller
Tiffany C. Miller
SMSalvatore Domenic Morgera
Salvatore Domenic Morgera
Stephen Edward  SaddowStephen Edward Saddow
Stephen Edward Saddow
ATArash Takshi
Arash Takshi
MPMatthew Palm
Matthew Palm
Electronic nose technology may have the potential to substantially slow the spread of contagious diseases with rapid signal indication. As our understanding of infectious diseases such as Corona Virus Disease 2019 improves, we expect electronic nose technology to detect changes associated with pathogenesis of the disease such as biomarkers of immune response for respiratory symptoms, central nervous system injury, and/or peripheral nervous system injury in the breath and/or odor of an individual. In this paper, a design of an electronic nose was configured to detect the concentration of a COVID-19 breath simulation sample of alcohol, acetone, and carbon monoxide mixture. After preheating for 24 hours, the sample was carried into an internal bladder of the collection vessel for analysis and data was collected from three sensors to determine suitability of these sensors for the application of exhaled breath analysis. Test results show a detection range in parts-per-million within the sensor detection range of at least 10–300 ppm. The output response of an MQ-2 and an MQ-135 sensor to a diverse environment of target gasses show the MQ-2 taking a greater length of time to normalize baseline drift compared to an MQ-135 sensor due to cross interferences with other gasses. The COVID-19 breath simulation sample was established and validated based on preliminary data obtained from parallel COVID-19 breath studies based in Edinburgh and Dortmund. This detection method provides a non-invasive, rapid, and selective detection of gasses in a variety of applications in virus detection as well as agricultural and homeland security.

1 January 2006 in MRS Proceedings
Verified
Journal Article
Closed access
PDF file
MRM. Reyes
M. Reyes
YSY. Shishkin
Y. Shishkin
SHS. Harvey
S. Harvey
Stephen Edward  SaddowStephen Edward Saddow
Stephen Edward Saddow