Arash Takshi

Dr. Arash Takshi

Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, USA
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Journal of Power Sources
Verified
Journal Article
Closed access
TTTete Tevi
Tete Tevi
ATArash Takshi
Arash Takshi

1 August 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
KPKavyashree Puttananjegowda
Kavyashree Puttananjegowda
ATArash Takshi
Arash Takshi
STSylvia Thomas
Sylvia Thomas

1 February 2015 in Journal of Power Sources
Verified
Journal Article
Closed access
ATArash Takshi
Arash Takshi
HYHouman Yaghoubi
Houman Yaghoubi
TTTete Tevi
Tete Tevi
SBSara Bakhshi
Sara Bakhshi

29 June 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
MBMohammad Beygi
Mohammad Beygi
JBJohn Bentley
John Bentley
CFChristopher L. Frewin
Christopher L. Frewin
CKCary A. Kuliasha
Cary A. Kuliasha
ATArash Takshi
Arash Takshi
Stephen Edward  SaddowStephen Edward Saddow
Stephen Edward Saddow
One of the main issues with micron-sized intracortical neural interfaces (INIs) is their long-term reliability, with one major factor stemming from the material failure caused by the heterogeneous integration of multiple materials used to realize the implant. Single crystalline cubic silicon carbide (3C-SiC) is a semiconductor material that has been long recognized for its mechanical robustness and chemical inertness. It has the benefit of demonstrated biocompatibility, which makes it a promising candidate for chronically-stable, implantable INIs. Here, we report on the fabrication and initial electrochemical characterization of a nearly monolithic, Michigan-style 3C-SiC microelectrode array (MEA) probe. The probe consists of a single 5 mm-long shank with 16 electrode sites. An ~8 µm-thick p-type 3C-SiC epilayer was grown on a silicon-on-insulator (SOI) wafer, which was followed by a ~2 µm-thick epilayer of heavily n-type (n+) 3C-SiC in order to form conductive traces and the electrode sites. Diodes formed between the p and n+ layers provided substrate isolation between the channels. A thin layer of amorphous silicon carbide (a-SiC) was deposited via plasma-enhanced chemical vapor deposition (PECVD) to insulate the surface of the probe from the external environment. Forming the probes on a SOI wafer supported the ease of probe removal from the handle wafer by simple immersion in HF, thus aiding in the manufacturability of the probes. Free-standing probes and planar single-ended test microelectrodes were fabricated from the same 3C-SiC epiwafers. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were performed on test microelectrodes with an area of 491 µm2 in phosphate buffered saline (PBS) solution. The measurements showed an impedance magnitude of 165 kΩ ± 14.7 kΩ (mean ± standard deviation) at 1 kHz, anodic charge storage capacity (CSC) of 15.4 ± 1.46 mC/cm2, and a cathodic CSC of 15.2 ± 1.03 mC/cm2. Current-voltage tests were conducted to characterize the p-n diode, n-p-n junction isolation, and leakage currents. The turn-on voltage was determined to be on the order of ~1.4 V and the leakage current was less than 8 μArms. This all-SiC neural probe realizes nearly monolithic integration of device components to provide a likely neurocompatible INI that should mitigate long-term reliability issues associated with chronic implantation.

27 April 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
TMTiffany C. Miller
Tiffany C. Miller
SMSalvatore Domenic Morgera
Salvatore Domenic Morgera
Stephen Edward  SaddowStephen Edward Saddow
Stephen Edward Saddow
ATArash Takshi
Arash Takshi
MPMatthew Palm
Matthew Palm
Electronic nose technology may have the potential to substantially slow the spread of contagious diseases with rapid signal indication. As our understanding of infectious diseases such as Corona Virus Disease 2019 improves, we expect electronic nose technology to detect changes associated with pathogenesis of the disease such as biomarkers of immune response for respiratory symptoms, central nervous system injury, and/or peripheral nervous system injury in the breath and/or odor of an individual. In this paper, a design of an electronic nose was configured to detect the concentration of a COVID-19 breath simulation sample of alcohol, acetone, and carbon monoxide mixture. After preheating for 24 hours, the sample was carried into an internal bladder of the collection vessel for analysis and data was collected from three sensors to determine suitability of these sensors for the application of exhaled breath analysis. Test results show a detection range in parts-per-million within the sensor detection range of at least 10–300 ppm. The output response of an MQ-2 and an MQ-135 sensor to a diverse environment of target gasses show the MQ-2 taking a greater length of time to normalize baseline drift compared to an MQ-135 sensor due to cross interferences with other gasses. The COVID-19 breath simulation sample was established and validated based on preliminary data obtained from parallel COVID-19 breath studies based in Edinburgh and Dortmund. This detection method provides a non-invasive, rapid, and selective detection of gasses in a variety of applications in virus detection as well as agricultural and homeland security.

4 February 2020 in IEEE Sensors Letters
Verified
Journal Article
Closed access
KPKavyashree Puttananjegowda
Kavyashree Puttananjegowda
ATArash Takshi
Arash Takshi
STSylvia Thomas
Sylvia Thomas
This paper presents a conductive polymer based electrospun-nanofibrous-membrane (ENFM) for enzymatic electrochemical glucose sensor. ENFM based sensor electrode shows a wide detection range from 0 mM to 25 mM concentration with a shorter response time of less than 4 sec and the sensitivity of $5.11 \mu\text{A}/ \text{mM}\; \text{cm}^2$ with limit of detection 2.2 μM in a glucose buffer solution. The sensing electrode shows negligible change in current response for upto 50 days. The sensing activity of electrode remained constant indicating a good long-term stability for the glucose sensor due to the direct immobilization of glucose oxidase (GOx) enzyme onto the surface of nanofibers. The electrochemical analysis results demonstrated that the ENFM based glucose sensor provides reliable results in terms of enhanced sensitivity, good stability, durability, and quick response time for glucose detection.