Background: Percutaneous closure of the left atrial appendage (LAA) is an alternative to chronic oral anticoagulation to reduce stroke risk in patients with nonvalvular atrial fibrillation. The Amulet IDE trial (Amplatzer Amulet Left Atrial Appendage Occluder IDE Trial) was designed to evaluate the safety and effectiveness of the dual-seal mechanism of the Amulet LAA occluder compared with the Watchman device. Methods: Patients with nonvalvular atrial fibrillation at increased risk of stroke were randomly assigned (1:1) to undergo percutaneous implantation of a LAA occluder with the Amulet occluder or Watchman device. The primary end points included safety (composite of procedure-related complications, all-cause death, or major bleeding at 12 months), effectiveness (composite of ischemic stroke or systemic embolism at 18 months), and the rate of LAA occlusion at 45 days. Prespecified secondary end points included a composite of all stroke, systemic embolism, or cardiovascular/unexplained death at 18 months, major bleeding at 18 months, and superiority test of the 3 primary end points. Results: A total of 1878 patients were enrolled. The Amulet occluder was noninferior to the Watchman device for the primary safety end point (14.5% versus 14.7%; difference=–0.14 [95% CI, –3.42 to 3.13]; P <0.001 for noninferiority). Major bleeding and all-cause death were similar between groups (10.6% versus 10.0% and 3.9% versus 5.1%, respectively). Procedure-related complications were higher for the Amulet occluder (4.5% versus 2.5%), largely related to more frequent pericardial effusion and device embolization. The Amulet occluder was noninferior to the Watchman device for the primary effectiveness end point (2.8% versus 2.8%; difference=0.00 [95% CI, –1.55 to 1.55]; P <0.001 for noninferiority), and the composite of stroke, systemic embolism, or cardiovascular/unexplained death (5.6% versus 7.7%, difference=–2.12 [95% CI, –4.45 to 0.21]; P <0.001 for noninferiority). The rate of major bleeding was similar between groups (11.6% versus 12.3%; difference=–0.71 [95% CI, –3.72 to 2.31]; P =0.32 for superiority). LAA occlusion was higher for the Amulet occluder than for the Watchman device (98.9% versus 96.8%; difference=2.03 [95% CI, 0.41–3.66]; P <0.001 for noninferiority; P =0.003 for superiority). Conclusions: The Amulet occluder was noninferior for safety and effectiveness of stroke prevention for nonvalvular atrial fibrillation compared with the Watchman device and superior for LAA occlusion. Procedure-related complications were higher with the Amulet occluder and decreased with operator experience. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02879448.
26 October 2020 in Journal of the American Geriatrics Society
Periprocedural imaging assessment for percutaneous Left Atrial Appendage (LAA) transcatheter occlusion can be obtained by utilizing different imaging modalities including fluoroscopy, magnetic resonance imaging (MRI), computed tomography (CT), and ultrasound imaging. Given the complex and variable morphology of the left atrial appendage, it is crucial to obtain the most accurate LAA dimensions to prevent intra-procedural device changes, recapture maneuvers, and prolonged procedure time. We therefore sought to examine the accuracy of the most commonly utilized imaging modalities in LAA occlusion. Institutional Review Board (IRB) approval was waived as we only reviewed published data. By utilizing PUBMED which is an integrated online website to list the published literature based on its relevance, we retrieved thirty-two articles on the accuracy of most commonly used imaging modalities for pre-procedural assessment of the left atrial appendage morphology, namely, two-dimensional transesophageal echocardiography, three-dimensional transesophageal echocardiography, computed tomography, and three-dimensional printing. There is strong evidence that real-time three-dimensional transesophageal echocardiography is more accurate than two-dimensional transesophageal echocardiography. Three-dimensional computed tomography has recently emerged as an imaging modality and it showed exceptional accuracy when merged with three-dimensional printing technology. However, real time three-dimensional transesophageal echocardiography may be considered the preferred imaging modality as it can provide accurate measurements without requiring radiation exposure or contrast administration. We will present the most common imaging modality used for LAA assessment and will provide an algorithmic approach including preprocedural, periprocedural, intraprocedural, and postprocedural.
Conventional access through femoral veins may be limited due to tortuosity and venous occlusion secondary to venous thrombosis or congenital anomalies. Another alternative is subclavian veins, but the difficulty in catheter manipulation and stability makes it less favorable in comparison to the transhepatic access for the delivery of the Watchman device.
1 May 2021 in Catheterization and Cardiovascular Interventions