Ultraviolet (UV) disinfection is a powerful method for inactivating viruses. However, comparative wavelength-dependent sensitivities among human viruses and bacteriophages remain poorly characterized. Here, we evaluated the virucidal efficiencies of UV-light emitting diode (UV-LED) against multiple coliphages (MS2, Qβ, PhiX174, and T1) and mammalian viruses, including respiratory syncytial virus (RSV) and human metapneumovirus (HMPV). We used a standardized irradiation system equipped with interchangeable UV-LED modules (250–365 nm), a low-pressure mercury lamp (254 nm), and a filtered krypton-chloride excimer lamp (222 nm). All coliphages exhibited wavelength-dependent inactivation with maximal efficiency at 263–270 nm, closely matching the action spectra of RSV and HMPV (r > 0.94, p < 0.001). However, their absolute UV sensitivities were markedly lower: under 254–281 nm irradiation. RSV and HMPV were approximately 21 and 12 times more sensitive than MS2, respectively. In contrast, far-UVC (222 nm) irradiation reduced these differences, indicating simultaneous damage to viral genomes and structural proteins. These results demonstrated that coliphages and human viruses exhibit similar wavelength-dependent sensitivity to UV-LED irradiation but differ in their absolute susceptibility. Therefore, while coliphages can be conservative surrogates for evaluating UV-LED virucidal performance, their applicability to far-UVC assessments should be interpreted with caution.
Irradiation with ultraviolet light-emitting diodes (UV-LEDs) represents a promising method for viral inactivation, but a detailed understanding of the wavelength-dependent action spectra remains limited, particularly across different viral components. In this study, we established standardized UV action spectra for infectivity reduction in pathogenic viruses using a system equipped with interchangeable LEDs at 13 different peak wavelengths (250–365 nm). The reduction in viral infectivity induced by UV-LED exposure was strongly related to viral genome damage, whereas no significant degradation of viral structural proteins was detected. Peak virucidal efficiency was observed at 267–270 nm across all tested viruses, representing a slight shift from the traditionally expected 260 nm nucleic acid absorption peak. Enveloped RNA viruses, including influenza A virus, respiratory syncytial virus, and coronavirus, exhibited greater UV sensitivity than nonenveloped viruses such as feline calicivirus and adenovirus. These observations indicate that structural characteristics, such as the presence of an envelope and genome organization, influence UV susceptibility. The wavelength-specific action spectra established in this study provide critical data for optimizing UV-LED disinfection systems to achieve efficient viral inactivation while minimizing energy consumption in healthcare, food safety, and environmental sanitation.