Deepan Balakrishnan

Dr. Deepan Balakrishnan

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
ADAbhik Datta
Abhik Datta
KNKian Fong Ng
Kian Fong Ng
DBDeepan Balakrishnan
Deepan Balakrishnan
MDMelissa Ding
Melissa Ding
SCSee Wee Chee
See Wee Chee
DLDuane Loh
Duane Loh
Fast, direct electron detectors have significantly improved the spatio-temporal resolution of electron microscopy movies. Preserving both spatial and temporal resolution in extended observations, however, requires storing prohibitively large amounts of data. Here, we describe an efficient and flexible data reduction and compression scheme (ReCoDe) that retains both spatial and temporal resolution by preserving individual electron events. Running ReCoDe on a workstation we demonstrate on-the-fly reduction and compression of raw data streaming off a detector at 3 GB/s, for hours of uninterrupted data collection. The output was 100-fold smaller than the raw data and saved directly onto network-attached storage drives over a 10 GbE connection. We discuss calibration techniques that support electron detection and counting (e.g., estimate electron backscattering rates, false positive rates, and data compressibility), and novel data analysis methods enabled by ReCoDe (e.g., recalibration of data post acquisition, and accurate estimation of coincidence loss).

4 November 2023 in Communications Physics
Verified
Journal Article
Open access
PDF file
DBDeepan Balakrishnan
Deepan Balakrishnan
SCSee Wee Chee
See Wee Chee
ZBZhaslan Baraissov
Zhaslan Baraissov
MBMichel Bosman
Michel Bosman
UMUtkur Mirsaidov
Utkur Mirsaidov
DLDuane Loh
Duane Loh
Three-dimensional (3D) imaging of thin, extended specimens at nanometer resolution is critical for applications in biology, materials science, advanced synthesis, and manufacturing. One route to 3D imaging is tomography, which requires a tilt series of a local region. However, capturing images at higher tilt angles is infeasible for such thin, extended specimens. Here, we explore a suitable alternative to reconstruct the 3D volume using a single, energy-filtered, bright-field coherent image. We show that when our specimen is homogeneous and amorphous, simultaneously inferring local depth and thickness for 3D imaging is possible in the near-field limit. We demonstrated this technique with a transmission electron microscope to fill a glaring gap for rapid, accessible 3D nanometrology. This technique is applicable, in general, to any coherent bright field imaging with electrons, photons, or any other wavelike particles.

30 August 2017 in Applied Optics
Verified
Journal Article
Closed access
PDF file
AHA. He
A. He
DBDeepan Balakrishnan
Deepan Balakrishnan
CQC. Quan
C. Quan
A regularized phase tracker (RPT) is an effective method for demodulation of single closed-fringe patterns. However, lengthy calculation time, specially designed scanning strategy, and sign-ambiguity problems caused by noise and saddle points reduce its effectiveness, especially for demodulating large and complex fringe patterns. In this paper, a simplified paraboloid phase model-based regularized phase tracker (SPRPT) is proposed. In SPRPT, first and second phase derivatives are pre-determined by the density-direction-combined method and discrete higher-order demodulation algorithm, respectively. Hence, cost function is effectively simplified to reduce the computation time significantly. Moreover, pre-determined phase derivatives improve the robustness of the demodulation of closed, complex fringe patterns. Thus, no specifically designed scanning strategy is needed; nevertheless, it is robust against the sign-ambiguity problem. The paraboloid phase model also assures better accuracy and robustness against noise. Both the simulated and experimental fringe patterns (obtained using electronic speckle pattern interferometry) are used to validate the proposed method, and a comparison of the proposed method with existing RPT methods is carried out. The simulation results show that the proposed method has achieved the highest accuracy with less computational time. The experimental result proves the robustness and the accuracy of the proposed method for demodulation of noisy fringe patterns and its feasibility for static and dynamic applications.

1 August 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
DBDeepan Balakrishnan
Deepan Balakrishnan
APAnupama Prakash
Anupama Prakash
BDBenedikt J. Daurer
Benedikt J. Daurer
CFCédric Finet
Cédric Finet
YLYing Chen Lim
Ying Chen Lim
DLDuane Loh
Duane Loh
How pigment distribution influences the cuticle density within a microscopic butterfly wing scale, and how both impact each scale’s final reflected color, remains unknown. We use ptychographic X-ray computed tomography to quantitatively determine, at nanoscale resolutions, the three-dimensional mass density of scales with pigmentation differences. By comparing cuticle densities between two pairs of scales with pigmentation differences, we determine that the density of the lower lamina is inversely correlated with pigmentation. In the upper lamina structure of Junonia orithya and Bicyclus anynana, low pigment levels also correlate with sheet-like chitin structures as opposed to rod-like structures. Within each scale, we determine that the lower lamina in all scales has the highest density, and distinct layers within the lower lamina help explain reflected color. We hypothesize that pigments, in addition to absorbing specific wavelengths, can affect cuticle polymerization, density, and refractive index, thereby impacting reflected wavelengths that produce colors.

12 April 2024 in Ultramicroscopy
Verified
Journal Article
Open access
JYJoel Yeo
Joel Yeo
BDBenedikt J. Daurer
Benedikt J. Daurer
DKDari Kimanius
Dari Kimanius
DBDeepan Balakrishnan
Deepan Balakrishnan
TBTristan Bepler
Tristan Bepler
DLDuane Loh
Duane Loh
Ewald sphere curvature correction, which extends beyond the projection approximation, stretches the shallow depth of field in cryo-EM reconstructions of thick particles. Here we show that even for previously assumed thin particles, reconstruction artifacts which we refer to as ghosts can appear. By retrieving the lost phases of the electron exitwaves and accounting for the first Born approximation scattering within the particle, we show that these ghosts can be effectively eliminated. Our simulations demonstrate how such ghostbusting can improve reconstructions as compared to existing state-of-the-art software. Like ptychographic cryo-EM, our Ghostbuster algorithm uses phase retrieval to improve reconstructions, but unlike the former, we do not need to modify the existing data acquisition pipelines.

22 July 2023 in Microscopy and Microanalysis
Verified
Journal Article
Open access
PDF file
DBDeepan Balakrishnan
Deepan Balakrishnan
APAnupama Prakash
Anupama Prakash
BDBenedikt Daurer
Benedikt Daurer
JKJustin Ong Jun Kiat
Justin Ong Jun Kiat
YTYong Zi Tan
Yong Zi Tan
NLN Duane Loh
N Duane Loh
The complexity of self-assembled photonic structures like butterfly wing scales spans 3–4 orders of magnitude in length scales. These monolithic structures produced by single cells on a butterfly wing typically measure a few hundred micrometres across, with intricate features going well below the nanometre scale. While this complexity makes the self-assembly of these structures fascinating, imaging and capturing this gamut of complexity is extremely challenging. The available imaging methods can either capture the overall field of view at a lower resolution (scanning electron microscopy (SEM)) or can capture high-resolution details of the structure at a specific region (resin section transmission electron microscopy) [ 1]. Further, three-dimensional (3D) characterization techniques either can only image the topology of a single surface (atomic force microscopy) [ 1] or are limited to fewer synchrotron facilities (ptychographic x-ray tomography (PXCT)) [ 2], rendering them impractical to promptly test a large number of scales for gene expression studies.