Heitor Oliveira Gonçalves

Dr. Heitor Oliveira Gonçalves

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2026 in Journal of Performance of Constructed Facilities
Verified
Journal Article
Closed access
PDF file
HGHeitor Oliveira Gonçalves
Heitor Oliveira Gonçalves
DPDarlan Porto
Darlan Porto
RARenato Amaral
Renato Amaral
GQGiovane Quadrelli
Giovane Quadrelli
Corrosion in steel structures represents a critical challenge in civil engineering, with economic losses exceeding 2.5 trillion dollars annually worldwide. Traditional visual inspection methods present significant limitations, including subjectivity, dependence on inspector experience, and difficulty accessing critical structural elements. Automated detection systems using deep learning offer a promising solution to enhance inspection objectivity and efficiency. This study presents a rigorous comparative analysis between U-Net and attention U-Net architectures for automated corrosion detection in ASTM A572 Grade 50 W-beams. A comprehensive data set was systematically developed comprising 217 original high-resolution images ( 512 × 512    pixels ) captured under controlled laboratory conditions from W-beam specimens with varying corrosion severity levels (6 months to 5 years of atmospheric exposure). After data augmentation, the final data set contained 414 images for model training and evaluation. Manual annotations were performed by three structural pathology specialists with interannotator agreement of κ = 0.87 . The attention U-Net architecture demonstrated statistically superior performance across all metrics: mean IoU of 0.775 ± 0.089 versus 0.693 ± 0.078 for U-Net (improvement of 11.8%, p < 0.001 , Cohen’s d = 0.98 ); Dice coefficient of 0.741 ± 0.067 versus 0.678 ± 0.071 (9.3% improvement); and F1-score of 0.823 ± 0.054 versus 0.751 ± 0.063 (9.6% improvement). False positive rate was reduced by 46% (12.8% versus 23.4%). For pitting corrosion detection, attention U-Net achieved 87.3% detection rate compared to 71.2% for classical U-Net. These results conclusively demonstrate that incorporating attention mechanisms substantially improves automated corrosion detection capability, offering a practical tool for nondestructive inspection of ASTM A572 Grade 50 steel structures with accuracy approaching interexpert agreement levels [0.80–0.85 intersection over union (IoU)].

20 May 2026 in Advances in Structural Engineering
Verified
Journal Article
Closed access
RARenato Amaral
Renato Amaral
TGThiago Cerqueira Gallou
Thiago Cerqueira Gallou
HGHeitor Oliveira Gonçalves
Heitor Oliveira Gonçalves
JPJosé Cristiano Pereira
José Cristiano Pereira
Technical standards for seismic retrofitting of reinforced concrete (RC) columns through jacketing address capacity calculations, yet the planning phase lacks structured methodologies for systematic risk assessment. This paper presents a Bowtie-based framework integrating threat identification, barrier specification, and cost-benefit analysis for column jacketing interventions. Developed through Design Science Research combining literature synthesis and consultation with eight experienced professionals, the framework identifies six threats and five consequence categories, specifying eleven barriers (six preventive, five mitigating) with explicit baseline effectiveness values, aligned with ACI 318, Eurocode 8, ISO 31000, and OSHA standards. Sensitivity analysis through one-at-a-time variation and Monte Carlo simulation ( N = 10,000) confirms robustness, with ±20% barrier effectiveness variation producing consistent ordinal-level risk changes across all threats. Cost-benefit analysis shows preventive barriers require 13–25% of intervention costs, while failure consequences—comprising demolition, reconstruction, litigation, and schedule penalties—may represent substantial multiples of the original budget. An illustrative case study demonstrates systematic risk-level reduction across all threats with 13.5% barrier investment. The framework advances risk management from reactive troubleshooting to proactive, risk-informed planning in structural rehabilitation.

2 September 2025 in Revista de Gestão e Secretariado
Verified
Journal Article
Open access
PDF file
HGHeitor Oliveira Gonçalves
Heitor Oliveira Gonçalves
JPJosé Cristiano Pereira
José Cristiano Pereira
RARenato Amaral
Renato Amaral
DPDarlan Porto
Darlan Porto
CECleber Esteves
Cleber Esteves
This study presents a risk analysis approach for artificial intelligence systems using a hybrid methodology that combines FMEA (Failure Mode and Effects Analysis) with Machine Learning techniques. The proposed methodology aims to identify and mitigate potential risks in AI systems, considering both technical and operational aspects. The developed framework integrates qualitative and quantitative analysis, enabling more accurate assessment of failure modes and their impacts. Results demonstrate that the hybrid approach offers greater precision in identifying critical risks compared to traditional methods. Validation was performed through case studies in different application domains, showing the versatility and effectiveness of the proposed methodology. The contributions include a new risk analysis framework, specific metrics for AI systems, and practical implementation guidelines. The findings suggest that FMEA-ML integration can significantly improve reliability and safety of artificial intelligence systems in critical environments, providing a robust tool for risk management.