Mariano Fernandez-Fairen

Dr. Mariano Fernandez-Fairen

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2013 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
PDF file
MFMariano Fernandez-Fairen
Mariano Fernandez-Fairen
DHDaniel Hernández-Vaquero
Daniel Hernández-Vaquero
AMAntonio Murcia
Antonio Murcia
ATAna Torres
Ana Torres
RLRafael Llopis
Rafael Llopis
Porous tantalum is an option of cementless fixation for TKA, but there is no randomized comparison with a cemented implant in a mid-term followup. We asked whether a tibial component fixed by a porous tantalum system might achieve (1) better clinical outcome as reflected by the Knee Society Score (KSS) and WOMAC Osteoarthritis Index, (2) fewer complications and reoperations, and (3) improved radiographic results with respect to aseptic loosening compared with a conventional cemented implant. We randomized 145 patients into two groups, either a porous tantalum cementless tibial component group (Group 1) or cemented conventional tibial component in posterior cruciate retaining TKA group (Group 2). Patients were evaluated preoperatively and 15 days, 6 months, and 5 years after surgery, using the KSS and the WOMAC index. Complications, reoperations, and radiographic failures were tallied. At 5-year followup the KSS mean was 90.4 (range, 68–100; 95% CI, ± 1.6) for Group 1, and 86.5 (range, 56–99; 95% CI, ± 2.4) for Group 2. The effect size, at 95% CI for the difference between means, was 3.88 ± 2.87. The WOMAC mean was 15.1 (range, 0–51; 95% CI, ± 2.6) for the Group 1, and 19.1 (range, 4–61; 95% CI, ± 2.9) for Group 2. The effect size for WOMAC was −4.0 ± 3.9. There were no differences in the frequency of complications or in aseptic loosening between the two groups. Our data suggest there are small differences between the uncemented porous tantalum tibial component and the conventional cemented tibial component. It currently is undetermined whether the differences outweigh the cost of the implant and the results of their long-term performance. Level I, therapeutic study. See Instructions to Authors for a complete description of levels of evidence.

1 July 2011 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Open access
PDF file
MFMariano Fernandez-Fairen
Mariano Fernandez-Fairen
AMAntonio Murcia-Mazón
Antonio Murcia-Mazón
ATAna Torres
Ana Torres
VQVirginia Querales
Virginia Querales
AMAntonio Murcia
Antonio Murcia
Conversion of hip arthrodesis to a THA reportedly provides a reasonable solution, improving function, reducing back and knee pain, and slowing degeneration of neighboring joints associated with a hip fusion. Patients generally are satisfied with conversion despite the fact that range of mobility, muscle strength, leg-length discrepancy (LLD), persistence of limp, and need for assistive walking aids generally are worse than those for conventional primary THA. We compared THA after hip arthrodesis and primary THA to determine whether these procedures would be associated with similar functional scores, maintenance of scores with time, complications and failures, survivorship of the arthroplasty, and patient satisfaction. We retrospectively matched 48 patients undergoing conversion of a fused hip to a THA between January 1980 and January 2000, with 50 patients receiving a primary THA during the same period. We prospectively followed all patients between January 2000 and January 2010. The changes in function and pain after THA were compared between the two cohorts using the Harris hip score (HHS) and the Rosser Index Matrix (RIM). The Oxford hip score (OHS) and the SF-36 also were used to assess quality of life (QOL) during followup. Complications were collected and survivorship of the THA was evaluated. Patient satisfaction was assessed using the Robertsson and Dunbar questionnaire. The minimum followup was 10 years (mean, 17 years; range, 10–29 years). At last followup, hip function and health-related QOL were similar for patients having conversion of hip arthrodesis to THA and for patients having a routine THA. Scores diminished overall in the two groups between 2000 and 2010, but without a difference for the HHS, RIM QOL, and OHS in the study cohort. The rate of complications, THA survival, and patient satisfaction were similar in both groups. Conversion of hip arthrodesis to a THA provides substantial improvement of hip function and health-related QOL, with an acceptable rate of complications, good expectancy of survival for the arthroplasty, and high level of patient satisfaction comparable to those of primary THA. Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

1 February 2019 in World Neurosurgery
Verified
Journal Article
Closed access
MFMariano Fernandez-Fairen
Mariano Fernandez-Fairen
EAEnrique Alvarado
Enrique Alvarado
ATAna Torres
Ana Torres

15 September 2012 in Spine
Verified
Journal Article
Closed access
MFMariano Fernandez-Fairen
Mariano Fernandez-Fairen
AMAntonio Murcia
Antonio Murcia
ATAna Torres
Ana Torres
DHDaniel Hernández-Vaquero
Daniel Hernández-Vaquero
AMAnn M. Menzie
Ann M. Menzie
Study Design. Retrospective cost-effectiveness analysis. Objective. To determine the relative cost-effectiveness of anterior cervical discectomy with fusion (ACDF) using a porous tantalum implant compared with autograft with plating, for single-level cervical disc disease with radiculopathy. Summary of Background Data. ACDF with autograft as an interbody spacer is a generally accepted method to treat degenerated cervical discs with radiculopathy. Concerns about donor site morbidity and the structural characteristics of autograft stimulated investigations of alternative materials. Techniques may differ in their operative risks, complications, outcomes, and resource use. Methods. A retrospective review of clinical outcomes and total cost of illness for 5 years postsurgery was performed for 61 consecutive patients enrolled for this study. Twenty-eight patients were treated with single-level ACDF using either a stand-alone, porous tantalum implant, without graft inside the implant, and 33 patients received autograft and plating. A cost-effectiveness analysis comparing the 2 ACDF treatment methods was conducted. This article reports clinical assessments, quality adjusted life years gained, and an incremental cost-effectiveness ratio analysis. Results. Patients in both cohorts reported improved clinical outcomes, including neck disability index, visual analogue scale, Short-Form 36, Odom's clinical assessment, and patient satisfaction at 5 years postindex surgery. The mean cost of illness for the study period, including preoperative through 5 years postoperative assessments, was 6806 € per patient treated with tantalum and 10,143 € per patient receiving autograft and plate. Quality-adjusted life years (QALY) gained were 9.41 and 7.14 for the tantalum and control cohorts, respectively. The cost per QALY for the tantalum group was 723 € and 1420 € for the control group. The incremental cost-effectiveness ratio of ACDF with a porous tantalum implant compared with ACDF with autograft and plate was −1473 € per patient per year for the duration of this study. Conclusion. This cost-effectiveness analysis reports favorable results for ACDF procedures utilizing a tantalum implant. The data reported suggest that using porous tantalum as a stand-alone device is less costly and more effective than autograft and plate in ACDF procedures.

Verified
Journal Article
Open access
PDF file
MOMonica Ortiz-Hernandez
Monica Ortiz-Hernandez
KRKatrin S. Rappe
Katrin S. Rappe
MMMeritxell Molmeneu Molmeneu
Meritxell Molmeneu Molmeneu
Carles Mas MorunoCarles Mas Moruno
Carles Mas Moruno
JGJordi Guillem-Marti
Jordi Guillem-Marti
Javier GilJavier Gil
Javier Gil
In this study, highly-interconnected porous titanium implants were produced by powder sintering with different porous diameters and open interconnectivity. The actual foams were produced using high cost technologies: Chemical Vapor Deposition (CVD), Physical Vapor Deposition (PVD), and spark plasma sintering, and the porosity and/or interconnection was not optimized. The aim was to generate a bioactive surface on foams using two different strategies, based on inorganic thermo-chemical treatment and organic coating by peptide adsorption, to enhance osseointegration. Porosity was produced using NaCl as a space holder and polyethyleneglicol as a binder phase. Static and fatigue tests were performed in order to determine mechanical behaviors. Surface bioactivation was performed using a thermo-chemical treatment or by chemical adsorption with peptides. Osteoblast-like cells were cultured and cytotoxicity was measured. Bioactivated scaffolds and a control were implanted in the tibiae of rabbits. Histomorphometric evaluation was performed at 4 weeks after implantation. Interconnected porosity was 53% with an average diameter of 210 µm and an elastic modulus of around 1 GPa with good mechanical properties. The samples presented cell survival values close to 100% of viability. Newly formed bone was observed inside macropores, through interconnected porosity, and on the implant surface. Successful bone colonization of inner structure (40%) suggested good osteoconductive capability of the implant. Bioactivated foams showed better results than non-treated ones, suggesting both bioactivation strategies induce osteointegration capability.

17 February 2023 in Current Medical Research and Opinion
Verified
Journal Article
Open access
MFMariano Fernandez-Fairen
Mariano Fernandez-Fairen
CCCarlos Alberto Calderón-Ospina
Carlos Alberto Calderón-Ospina
JCJuythel Chen
Juythel Chen
MVManuel Duarte Vega
Manuel Duarte Vega
FFFreddy Fernández-Villacorta
Freddy Fernández-Villacorta
GVGrisell Vargas-Schaffer
Grisell Vargas-Schaffer
The term “mixed pain” has been established when a mixture of different pain components (e.g. nociceptive, neuropathic, and nociplastic) are present. It has gained more and more acceptance amongst p...