The development of power grid infrastructure and increasingly stringent environmental regulations have intensified work, carried out by researchers and electrical equipment manufacturers, to develop innovative gas-insulated, environmentally neutral devices. The emergence of new designs of circuit breakers and disconnectors, in which the resulting electric arc is extinguished in a vacuum environment, requires the development of appropriate techniques for diagnosing the chambers responsible for the dielectric parameters of the device. The following article presents an overview of the directions of development of diagnostic methods for medium-voltage vacuum switching equipment, which can potentially be used to develop a real-time pressure monitoring system that can be applied to vacuum switching equipment used in electrical infrastructure.
This paper presents the results of a comparative analysis of the dielectric strength of disconnecting vacuum interrupters operating on air and helium. The breakdown voltage Ud was measured in the pressure range from 8.0 × 10−4 Pa to 3.0 × 101 Pa for air and from 8.0 × 10−4 Pa to 7.0 × 102 Pa for helium, while varying the interelectrode distance from 1.0 to 5.0 mm. Dedicated laboratory workstations were used to determine the actual pressure values in the vacuum interrupters tested and to precisely measure and record the dielectric strength results of the test object. It was found that the helium-filled vacuum interrupter maintains its full dielectric strength in significantly larger pressure ranges, while the air-filled vacuum interrupter loses its insulating properties. Thus, it is possible to make vacuum interrupters based on the working medium associated with pure helium, with larger working pressure ratings. Under such conditions, it is easier to maintain the tightness of the device and to limit cut-off currents and overvoltages associated with vacuum switchgear.
31 March 2021 in Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
W artykule opisano autorski sposób pozwalający na określenie rzeczywistej wartości ciśnienia w próżniowej komorze rozłącznikowej SN podczas wysokonapięciowych badań laboratoryjnych. Konieczność opracowania metody tego typu wynikła z braku możliwości pomiaru ciśnienia bezpośrednio w komorze próżniowej w trakcie badań. Istniało bowiem ryzyko uszkodzenia próżniomierza w wyniku przeskoku elektrycznego. Proponowana metoda polega na pomiarze w warunkach beznapięciowych różnicy ciśnienia pomiędzy zestawem pomp próżniowych, a prototypem komory próżniowej wykonanym dla potrzeb realizacji tej metody. Dzięki temu znając wartość ciśnienia przy pompach oraz mając wyznaczone charakterystyki skalowania układu, w trakcie badań wysokonapięciowych możliwe będzie określenie rzeczywistego ciśnienia wewnątrz badanej rozłącznikowej komory gaszeniowej SN. Przeprowadzono pomiary spadku ciśnienia w kanale pompowym dla powietrza oraz trzech gazów elektroujemnych: helu, argonu oraz neonu, wykorzystywanych w badaniach przez autorów niniejszego artykułu.
Innovation in the economy is closely tied to energy development, encompassing the exploration of new energy sources, increased energy production efficiency, and the integration of diverse energy sources for safe and effective supply to industries and households. Outdated energy infrastructure disrupts electricity continuity and hampers economic innovation. Power interruptions lead to higher SAIDI and SAIFI reliability indices. Quality and reliability requirements have sparked interest in enclosed energy devices. Vacuum technology has been pivotal in electrical switchgear insulation and arc-quenching for over four decades. However, the lack of real-time pressure monitoring systems for vacuum equipment, especially enclosed disconnectors, limits their use as isolation connectors. Potential insulation failure poses risks to power line maintenance teams and can lead to unplanned shutdowns, further compromising energy supply quality. This article explores an innovative pressure monitoring system for vacuum interrupters, utilizing fiber optic Bragg grids as a measuring sensor, enabling pressure measurement within the vacuum chamber ranging from 2 × 101 Pa to 5 × 105 Pa.
The paper describes an innovative laboratory station based on a so-called demountable vacuum chamber and presents the results of electrical strength measurements using it. The pressure in the chamber was increased by injecting air, neon, and helium into it. It was found that the chamber with residual gases in the form of helium, in comparison with air and neon, retains its full insulating capacity over a much larger range of pressure values.
This article presents a comparison of empirical and simulation studies and the parameters declared by the membrane manufacturer. The analysis concludes that these values differ at each stage. Therefore, a numerical and simulation analysis of an optimal flat membrane was undertaken, which will successfully perform measurement functions across the full pressure range without causing inelastic deformations based on a membrane made of 316 L stainless steel with the following mechanical parameters: Young’s modulus , Poisson’s ratio , density , and yield strength 2.8 × 108 Pa. A diaphragm with an outer diameter of 25.4 mm, an inner diameter of , and a thickness of t = was designed for a pressure sensor in vacuum extinguishing chambers of medium-voltage devices, with a pressure difference from 7 × 10−4 Pa to 1.013 × 105 Pa. Finite element method (FEM) simulations in the COMSOL Multiphysics environment showed maximum von Mises reduced stresses 1.96 × 108 Pa below the yield strength, confirming operation in the linear-elastic range. The central deflection, described analytically by the equation , increased fivefold with an increase in diameter to (active area A = 1.14 × 10−3 m2 compared to 5.07 × 10−4 m2), achieving a metrological sensitivity of 9.1 × 10−10 m/Pa. Experimental studies integrated with Bragg FBG and epoxy adhesive (E = 5 × 109 Pa, tensile strength ) revealed a significant deviation from the manufacturer’s catalog data (e.g., deflection of at ), resulting from uneven bonding and a lack of coaxiality. Corrugated membranes with t = exceeded plasticity, while the optimized configuration of a smooth membrane with rounded adhesive edges () enabled precise pressure monitoring below , despite technological restrictions on assembly and miniaturization.