Damage in joints has a significant effect on the integrity and stability of the China Railway Track System (CRTS)II slab track. In this study, a three-dimensional finite element model was established to investigate the damage law of joints in the CRTSII slab track under temperature and vehicle loads. In the finite element model, the non-linear constitutive law and damage parameter of the interface between the slabs and the cement asphalt (CA) mortar layer were defined by a cohesive zone model. Based on the limited results in this analysis, the recommendations of joint damage repair were put forward. Results show that in the formation of joint damage in CRTSII slab track, the temperature load plays a more important role compared with the vehicle load. The more the concrete loss at the narrow joint, the lower the temperature rise at which concrete stress reaches its compressive strength. If concrete loss at the bottom of the narrow joint is no more than 10%, the damaged joint can be repaired at the time when the temperature of slabs is close to the construction temperature. If concrete loss at the bottom of the narrow joint is larger than 10%, repair strategy should be taken according to the time when the joint damage is detected. During repair, improving bond strength of the interface between the slabs and the CA mortar layer and strength of joint concrete can help to prevent the repaired joint from being damaged again.
There is confusion in the original design concept for the tensioning of longitudinally connected reinforcement of the CRTSII (China Railway Track System) slab ballastless track. In order to clarify the effect of tension value of longitudinal reinforcement on the mechanical characteristics of the ballastless track, a three-dimensional finite element model, considering the nonlinear interaction between the track slab and cement-emulsified asphalt (CA) mortar of the CRTSII slab ballastless track, was established. The mechanical characteristics of the track structure under longitudinal tension load and temperature gradient load of the longitudinal joint were calculated. A method of applying prestress to post-pouring concrete was proposed according to the concept of prestress loss of pretensioning prestressed concrete, a reasonable tensile force value was proposed after the crack width, and the reinforcement stress of the ballastless track in the operation stage was checked and calculated according to the concrete design principle. When the tension force is greater than 300 kN, it is harmful to the bonding between the slab and mortar layer, which is prone to interlayer damage. In order to add prestress to concrete with wide joints to ensure the longitudinal stability of the ballastless track, and that the reinforcement stress and crack width meet design requirements, it is suggested that the tension force value should be 230 kN. Further, the temperature difference between reinforcement and concrete should be 30 °C before the initial curdle of wide joint concrete.
15 December 2022 in Tehnicki vjesnik - Technical Gazette
Intermodal road-rail transportation (IRRT) integrates the advantages of railways and roads to achieve a win-win situation for all participants. However, the interest game problem of IRRT affects the enthusiasm of each sub-carrier to cooperate, which...
There is a confusion in the original design concept for the tensioning of longitudinally connected reinforcement of CRTSII slab ballastless track. In order to clarify the effect of tension value of longitudinal reinforcement on mechanical characteristics of ballastless track, a three dimensional finite element model considering the nonlinear interaction between the track slab and CA mortar of CRTSII slab ballastless track was established. The mechanical characteristics of the track structure under longitudinal tension load and temperature gradient load of the longitudinal joint were calculated. A method of applying pre-stress to post-pouring concrete was proposed according to the concept of pre-stress loss of pretensioning pre-stressed concrete, reasonable tensile force value was proposed after the crack width and the reinforcement stress of the ballastless track in the operation stage were checked and calculated according to the concrete design principle. When the tension force is greater than 300 kN, it’s harmful to the bonding between the slab and mortar layer, which is prone to interlayer damage. In order to adding pre-stress to concrete of wide joints to ensure the longitudinal stability of ballastless track and the reinforcement stress and crack width to meet the design requirements. It is suggested that the tension force value should be 230 kN, and the temperature difference between reinforcement and concrete should be 30 °C before the initial curdle of wide joint concrete.
This study investigates the decoupling relationship between meteorological comfort and urban rail transit ridership in China. Daily meteorological data and passenger volume data from 28 major cities were processed to construct a meteorological comfort index using the entropy weighting method, in which precipitation levels were converted into continuous values based on national standards. A decoupling model was then applied to examine the dynamic interaction between weather comfort and transit use. The analysis identifies three classes of decoupling states: Class A, where passenger travel remains stable despite unfavorable weather; Class B, where moderate sensitivity to meteorological variation is observed; and Class C, where travel is strongly influenced by weather conditions. Results show that most cities predominantly fall under Class B, but with notable fluctuations across seasons and regions. The findings highlight that meteorological comfort does not uniformly determine ridership, but instead reveals differentiated patterns of resilience and vulnerability across urban rail systems. This contributes to a deeper understanding of how external environmental factors interact with public transit demand and provides methodological guidance for improving the robustness of transport planning under climate variability.
1 January 2026 in Structural Control and Health Monitoring
Derailment accidents of high‐speed trains (HSTs) occur occasionally. How to enable derailed vehicles to decelerate and come to a stop as much as possible along the track alignment is the last line of defense for mitigating the losses caused by HST derailment disasters. To address the complex collision and contact behaviors between vehicle and track components during the derailment process, a dynamic interaction model of the vehicle–track system was developed. Through HST derailment tests, the validity of the vehicle–track coupled dynamic model established in this study for the whole derailment process was verified. This paper studied the regulatory influence of on‐board protective devices (OBPDs) on the running attitude of HSTs. It analyzed the effects of factors such as train speeds and the installation positions of OBPDs on the running attitude of HSTs after derailment and revealed the influence mechanism of OBPDs on the disaster mitigation effect of HSTs after derailment. The results indicate that the stability of the vehicle after derailment is optimal when the distance between the protective device and the outer side of the wheel is lp = 140∼190 mm. However, even with protective devices installed, the risk of vehicle body rollover remains significant when the train speed exceeds 330 km/h. The findings provide a theoretical foundation for ensuring the safe operation of HSTs.