Seng Wang

Dr. Seng Wang

School of Precision Instruments and Optoelectronics Engineering, Tianjin University

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2017 in Sensors
Verified
Journal Article
Open access
PDF file
ZRZhang Rui
Zhang Rui
SLShugui Liu
Shugui Liu
SWSeng Wang
Seng Wang
XSXuanxiao Song
Xuanxiao Song
The light-pen coordinate measuring machine (LPCMM for short) is portable and flexible to measure features including invisible ones in-situ. Since different styluses are needed to measure different features and even during the process of measuring a single workpiece with complicated configurations, to improve the system measurement accuracy it is beneficial to calibrate the stylus tip center position after it is mounted to the light-pen before measurement in an industrial field. A novel and simple method aiming at self-calibrating the position of the tip center based on invariable distances is presented. The distinguishing feature of the proposed method is that the center position of the tip can be calibrated by using a kinematic seat with an inverted cone hole without any external reference and auxiliary devices. Calibration is based on that the distance between the tip center and that of any LED is invariable when the light-pen is swung smoothly with its spherical tip firmly touching the fixed cone seat. To ensure the repeatability of the algorithm some error constraint parameters are given. Based on invariable distances, the tip center position in the light-pen coordinate system can be obtained. Experiment results show that the self-calibration method has the advantage of good repeatability, with standard deviations 0.027, 0.023 and 0.014 mm in U, V and W directions, respectively. Experimental results of measuring a circle and a gauge block indirectly demonstrate the accuracy of the proposed self-calibration method.

13 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
QMQing Mao
Qing Mao
SLShugui Liu
Shugui Liu
SWSeng Wang
Seng Wang
XMXinhui Ma
Xinhui Ma
Non-uniform rational B-spline (NURBS) surface fitting from data points is wildly used in the fields of computer aided design (CAD), medical imaging, cultural relic representation and object-shape detection. Usually, the measured data acquired from coordinate measuring systems is neither gridded nor completely scattered. The distribution of this kind of data is scattered in physical space, but the data points are stored in a way consistent with the order of measurement, so it is named quasi scattered data in this paper. Therefore they can be organized into rows easily but the number of points in each row is random. In order to overcome the difficulty of surface fitting from this kind of data, a new method based on resampling is proposed. It consists of three major steps: (1) NURBS curve fitting for each row, (2) resampling on the fitted curve and (3) surface fitting from the resampled data. Iterative projection optimization scheme is applied in the first and third step to yield advisable parameterization and reduce the time cost of projection. A resampling approach based on parameters, local peaks and contour curvature is proposed to overcome the problems of nodes redundancy and high time consumption in the fitting of this kind of scattered data. Numerical experiments are conducted with both simulation and practical data, and the results show that the proposed method is fast, effective and robust. What’s more, by analyzing the fitting results acquired form data with different degrees of scatterness it can be demonstrated that the error introduced by resampling is negligible and therefore it is feasible.