Mohamed BENCHEIKH

Dr. Mohamed BENCHEIKH

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2017 in Moscow University Physics Bulletin
Verified
Journal Article
Closed access
PDF file
Abdessamad DidiAbdessamad Didi
Abdessamad Didi
ADAhmed Dadouch
Ahmed Dadouch
MBMohamed BENCHEIKH
Mohamed BENCHEIKH
OJOtman Jai
Otman Jai
The neutron activation analysis is a method of exclusively elemental analysis. Its implementation of irradiates the sample which can be analyzed by a high neutron flux, this method is widely used in d

9 September 2017 in Physics of Particles and Nuclei Letters
Verified
Journal Article
Closed access
PDF file
MBMohamed BENCHEIKH
Mohamed BENCHEIKH
AMAbdelmajid Maghnouj
Abdelmajid Maghnouj
JTJaouad Tajmouati
Jaouad Tajmouati
Abdessamad DidiAbdessamad Didi
Abdessamad Didi
AEAhad Olah Ezzati
Ahad Olah Ezzati
The Monte Carlo model for the photon-beam output from the Varian Clinac 2100 linear accelerator was validated to compare the calculated to measured PDD and beam dose profiles The Monte Carlo...

25 November 2017 in Physics of Particles and Nuclei Letters
Verified
Journal Article
Closed access
PDF file
MBMohamed BENCHEIKH
Mohamed BENCHEIKH
AMAbdelmajid Maghnouj
Abdelmajid Maghnouj
JTJaouad Tajmouati
Jaouad Tajmouati
The Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy and beam characterization investigation, in this study, the Varian Clinac 2100 medi

1 November 2017 in Moscow University Physics Bulletin
Verified
Journal Article
Closed access
PDF file
MBMohamed BENCHEIKH
Mohamed BENCHEIKH
AMAbdelmajid Maghnouj
Abdelmajid Maghnouj
JTJaouad Tajmouati
Jaouad Tajmouati
Abdessamad DidiAbdessamad Didi
Abdessamad Didi
The objective of this study is to build a Monte Carlo geometry of Varian Clinac 2100 linear accelerator as realistically as possible and then to investigate the removing of flattening filter impact...

1 May 2017 in Moscow University Physics Bulletin
Verified
Journal Article
Closed access
PDF file
MBMohamed BENCHEIKH
Mohamed BENCHEIKH
AMAbdelmajid Maghnouj
Abdelmajid Maghnouj
JTJaouad Tajmouati
Jaouad Tajmouati
Determination and understanding the photon beam attenuation by the photon beam modifier and the radiation beam softening for clinical use is more important part of material study for the beam modifier enhancements and the linac improvements. A Monte Carlo model was used to simulate 6 MeV photon beams from a Varian Clinac 2100 accelerator with the flattening filter and the later was replaced by the aluminum slab with variable thickness. The Monte Carlo geometry was validated by a gamma index acceptance rate of 99% in PDD and 98% in dose profiles, the gamma criteria was 3% for dose difference and 3 mm for distance to agreement. The purpose was to investigate aluminum material attenuation and beam softening coefficients as a function of the inserted aluminum slab thickness and of off-axis distance. The attenuation and beam softening coefficients were not identical for the same off-axis distance and they varied as a function of aluminum slab thickness. The results of our study were shown that the beam softening coefficients were varied with thickness beam modifier material used for beam softening and the off-axis distance inside the irradiation field. Thereafter, the softening coefficient a1 have a maximum of 2.5 × 10–1 cm–1 for the aluminum slab thickness of 1 mm, 1.4 × 10–1 cm–1 for the aluminum slab thickness of 1.5 mm and 4.47 × 10–2 cm–1 for the aluminum slab thickness of 2 mm. The maximum of the second softening coefficient a2 was 1.02 × 10–2 cm–2 for the aluminum slab thickness of 1 mm, was 1.92 × 10–2 cm–2 for the aluminum slab thickness of 1.5 mm and was 1.93 × 10–2 cm–2 for the aluminum slab thickness of 2 mm. Our study can be a basic investigation of photon beam softening material that will be used in the future linac configuration and also in the photon beam modifiers.

25 November 2017 in Physics of Particles and Nuclei Letters
Verified
Journal Article
Closed access
PDF file
MBMohamed BENCHEIKH
Mohamed BENCHEIKH
AMAbdelmajid Maghnouj
Abdelmajid Maghnouj
JTJaouad Tajmouati
Jaouad Tajmouati
Determination and understanding of photon beam softening using material soften photon beam for clinical usage is important for material study for attenuation and for beam modifier enhancements and lin