Safety in the sustainable construction is a game with uncertain reality, with human’s life. Managers in power, involved in the construction project life cycle, create rules for the game and are the main players. The project’s success can be perceived differently by stakeholders. A company’s competitiveness, successful implementation of the projects and effective safety management depends on the strategic allocation of its human resources in order to select a proper project team in alignment with employee capabilities. This requires detailed factors reflecting their role (in line with their interests and attitudes) and knowing which of them has a decisive influence on the successful implementation of the project. The real data describing key factors in this concept can be provided as uncertain conditions. This work presents a novel integrated modified fuzzy group decision-making approach to select and rank the most influential persons ensuring the sustainable prevention of accidents at work in the small and medium-sized construction enterprises. This model includes the Delphi method and fuzzy extensions of Eckenrode’s criteria rating method. The proposed model could be expanded in order to select the most suitable individuals for sustainable management of safety and, moreover, for the effective implementation of safety and health measures.
28 June 2024 in Eastern-European Journal of Enterprise Technologies
Ensuring fire safety is the most important thing in the construction industry, especially when it comes to facade materials. The inherent flammability of polystyrene foam poses significant safety concerns, especially when integrated into facade systems. Therefore, the main focus is on meeting the strict flammability requirements set for construction products, which are assessed by applying rigorous test procedures. This study focuses on the fire resistance testing of a facade system using EPS 70 with graphite additives. The system has been evaluated according to the strict DIN 4102-20 standards. Tests were conducted under real-world conditions to gain insight into the performance of the EPS 70 in real-world fire scenarios. Temperature measurements were taken at various points in the facade system, including at least 3.5 meters above the combustion chamber. The results showed that the temperature does not exceed 500 °C, so it is possible to quantify the thermal properties of the material and the ability to prevent the vertical spread of fire. After the tests, detailed post-test inspections were carried out to evaluate the internal flame propagation after removing the top layer of plaster. The study confirms that polystyrene foam EPS 70 with graphite additives meets the fire safety requirements of DIN 4102-20, which suggests that it can be used more widely in building facades to improve fire safety in residential and commercial buildings. The study highlights the importance of adhering to installation standards, emphasizing the need for accurate installation practices. It also encourages the development of new composite materials with similar or improved fire safety properties, laying the foundation for further innovations in fire-resistant materials
The fire performance of ventilated facade systems incorporating combustible insulation remains a critical issue in contemporary building design. This study presents a full-scale natural-fire test of a ventilated, rendered facade system containing 150 mm expanded polystyrene (EPS) insulation, conducted in accordance with the DIN 4102-20 methodology. Temperature measurements were recorded at key facade locations via K-type thermocouples, and flame spread, materials melting, and degradation were documented through visual observations. The combustion chamber reached a peak temperature of 912 °C, while the thermocouple located above the opening recorded a maximum temperature of 786 °C. No sustained flaming or debris above the 3.5 m height limit was observed, yet significant internal EPS melting occurred throughout the cavity. These findings underscore the potency of the “chimney effect” in ventilated cavities, highlight the limitations of the current acceptance criteria, and provide evidence relevant to ongoing efforts to develop more coherent approaches to facade fire-safety assessment.