Kaan Can

Dr. Kaan Can

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2017 in International Journal of Applied Mathematics Electronics and Computers
Verified
Journal Article
Open access
PDF file
KCKaan Can
Kaan Can
ABAbdullah Başçi
Abdullah Başçi
Position Control of a Ball & Beam Experimental Setup Based on Sliding Mode Controller

1 June 2021 in Iğdır Üniversitesi Fen Bilimleri Enstitüsü Dergisi
Verified
Journal Article
Closed access
PDF file
MYMehmet Yilmaz
Mehmet Yilmaz
KCKaan Can
Kaan Can
ABAbdullah Başçi
Abdullah Başçi
One of the main problems in the control of the coupled tank liquid level systems, which are used frequently in water treatment systems and petrochemical industry today, is to determine the water flow rate between the two tanks. In this paper, proportional-integral +feed forward control method (PI+FF), whose parameters are determined using genetic algorithm (GA), one of the heuristic optimization methods, is used to solve this problem. In addition, in order to show the performance of the GA-based controller, the PI+FF controller that PI parameters obtained using the Ziegler-Nichols (Z-N) method are applied to the same system and the real-time application results of both controllers are compared. The experimental results showed that the controller, which parameters are determined by GA, reached the desired reference value with less settling time and less overshooting when it compared to the Z-N method based controller, and also it has given faster response to sudden changes in the system.

22 December 2016 in International Journal of Applied Mathematics Electronics and Computers
Verified
Journal Article
Open access
ABAbdullah Başçi
Abdullah Başçi
HSHayriye Tuğba Sekban
Hayriye Tuğba Sekban
KCKaan Can
Kaan Can
In this paper, real time application of a sliding mode control (SMC) is used for level control of experimental setup of liquid level system due to its properties such as robustness against large parameter variation and disturbances rejection. A well-tuned conventional proportional integral (PI) controller is also applied to the two coupled tank system for comparison with the SMC controller. Experimentation of the coupled tank system is realized in two different configurations, namely configuration #1 and configuration #2 respectively. In configuration #1, the water level in the top tank is controlled by a pump. In configuration #2, the water level in the bottom tank is controlled by the water flow coming out of the top tank. The performance of controllers is analysed according to their tracking performance and error elimination capability for different references applied to the system. Experimental results prove that the SMC shows better trajectory tracking performance than PI controller in that the plant transient responses to the desired output changes have shorter settling time and smaller magnitude overshot/undershoot. Robustness of the SMC with respect to water level variation and capability to eliminate external disturbances are also achieved.

20 April 2018 in Elektronika ir Elektrotechnika
Verified
Journal Article
Closed access
PDF file
KOKamil Orman
Kamil Orman
KCKaan Can
Kaan Can
ABAbdullah Başçi
Abdullah Başçi
ADAdnan Derdiyok
Adnan Derdiyok
In this paper, speed and direction angle of a four wheel skid-steered mobile robot (4 WD SSMR) has been controlled via adaptive-fuzzy fractional-order sliding mode controller (AFFOSMC) under different speed and angle reference signals. The hybrid control method is designed to combine all advantages that controllers have such as flexibility realized by fractional order calculation, robustness to disturbances and parameters variations provided by sliding mode controller (SMC) as well as adaptation of G constant of SMC via fuzzy controller, simultaneously. Also, a fractional-order SMC is applied to the system for the same reference speed and angle references to show the effects of the changes and adaptation of G constant. Experimental results show that the AFFOSMC has better trajectory tracking performance than the FOSMC.DOI: http://dx.doi.org/10.5755/j01.eie.24.2.20630

29 December 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FKFerhan Karadabağ
Ferhan Karadabağ
KCKaan Can
Kaan Can
Nowadays, optimization methods are widely used to adjust controller parameters and tune their optimal values in order to enhance the efficiency and performance of dynamic systems. In this study, the parameters of a linear Proportional–Integral (PI) controller were optimized by using five different optimization algorithms, such as Artificial Tree Algorithm (ATA), Particle Swarm Optimization (PSO), Differential Evolution Algorithm (DEA), Constrained Multi-Objective State Transition Algorithm (CMOSTA), and Adaptive Fire Forest Optimization (AFFO). The optimized controllers were implemented in real time for temperature control of a Heat-flow System (HFS) under various step and time-varying reference signals. In addition, the Ziegler–Nichols (Z–N) method was also applied to the system as a benchmark to compare the temperature tracking performance of the proposed optimization methods. To further evaluate the performance of each optimization algorithm, Mean Absolute Error (MAE) values were calculated, and improvement ratios were obtained. The experimental results showed that the proposed optimization methods provided more successful reference tracking and enhanced controller performance as well.