XU Dan

Dr. XU Dan


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
ZZZhi Zhang
Zhi Zhang
XDXU Dan
XU Dan
ZZzhang zhi
zhang zhi
GXGuobin Xu
Guobin Xu
In the proposed wind-storage combined operation technology, the storage side is foreseen to play a significant role in power system day-ahead generation scheduling. Based on the operational characteristics of pumped storage power stations, the day-ahead dispatching method of a power system with wind farms and pumped storage power stations is studied. The dispatching mode that aims at the lowest operating cost is proposed, taking into consideration the coordination relationship between the scheduling benefit of pumped storage power stations and the total peak-shaving economy of the system and the fluctuation of new energy output. First, taking the constraint of reservoir capacity, the output power, and the daily pumping power of the pumped storage power station into account, a day-ahead generation scheduling model is constructed, with the objective of minimizing costs. Then, the imperial competition algorithm is applied to the proposed model. Finally, the algorithm is compared with the standard particle swarm optimization algorithm. The simulation results based on standard 4-unit and 10-unit systems indicate that the proposed method is effective and robust for a power system with wind power and pumped storage power stations.

16 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
JYJiang Yingying
Jiang Yingying
XCXiaolin Chen
Xiaolin Chen
SPSui Peng
Sui Peng
XDXiao Du
Xiao Du
XDXU Dan
XU Dan
WLWenyuan Li
Wenyuan Li
When large-capacity HVDC (high voltage direct current) transmission line blocking occurs in a hybrid AC/DC (alternating current/direct current) power grid, the receiving-end system will encounter a huge power imbalance, which will lead to a frequency drop and redistribution of the power flow, and which may further lead to the overload of other transmission lines, cascading failures and a large-scale blackout. To resolve these problems, an emergency load-shedding strategy for the DC receiving-end system is proposed from the perspective of a quasi-steady state. The proposed method can accurately calculate the actual total power imbalance by modeling more detailed stochastic loads with static frequency/voltage characteristics and involving the inertia effect of the generator during the response delay period, which can effectively reduce the amount of load curtailment. In addition, several factors affecting the power imbalance estimation in stochastic scenarios and their mechanisms are analyzed in detail, and the key aspects relevant to the DC blocking fault analysis are identified as well. Finally, the influence of different load-shedding strategies on the receiving-end system security after a DC blocking fault is compared with the security indices, including those that are relevant to the frequency/load change proposed herein, and a uniform load-shedding coefficient is obtained via the proposed method, even for different power imbalances under a stochastic context, which makes the load-shedding strategy more practical.

1 January 2024 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Closed access
XDXU Dan
XU Dan
ZCZhi Cai
Zhi Cai
QCQian Cheng
Qian Cheng
GHGuodong Huang
Guodong Huang
JZJingyang Zhou
Jingyang Zhou
JTJunjie Tang
Junjie Tang
With the large-scale integration of renewable energy, the traditional maintenance arrangement during the load valley period cannot satisfy the transmission demand of renewable energy generation. Simultaneously, in a market-oriented operation mode, the power dispatching control center aims to reduce the overall power purchase cost while ensuring the security of the power system. Therefore, a security-constrained transmission maintenance optimization model considering generation and operational risk costs is proposed herein. This model is built on double-layer optimization framework, where the upper-layer model is used for maintenance and generation planning, and the lower-layer model is primarily used to address the operational security risk arising from the random prediction error and $N-1$ transmission failure. Correspondingly, a generation-maintenance iterative algorithm based on a defined cost feedback is included to increase solution efficiency. Generation cost is determined using long-term security-constrained unit commitment, and the operational risk cost is obtained using a double-layer $N-1$ risk assessment model. An electrical correlation coupling coefficient is proposed for the solution process to avoid maintenance of associated equipment simultaneously, thereby improving model convergence efficiency. The IEEE 118-bus system is used as a test case for illustration, and test results suggest that the proposed model and algorithm can reduce the total cost of transmission maintenance and system operation while effectively improving the solution efficiency of the joint optimization model.

14 August 2019 in Energies
Verified
Journal Article
Open access
PDF file
CLCong Liu
Cong Liu
JZJingyang Zhou
Jingyang Zhou
YPYi Pan
Yi Pan
ZLZhiyi Li
Zhiyi Li
YWYifei Wang
Yifei Wang
Mohammad ShahidehpourMohammad Shahidehpour
Mohammad Shahidehpour
The integration of shiftable/curtailment distribution generators (DGs) along with quick-response storage has not only increased the transaction’s flexibility but also puzzled the bidding willingness of transmission-connected market players (TMPs). In this paper, the method of heterogeneous decomposition and coordination (HGDC) is applied to decompose the integrated transmission-distribution market framework into a bi-level problem with a transmission wholesale market master problem and several distribution retail market subproblems in a decentralized organization structure. The price-based bidding willingness of demand-side resources’ (DSRs’) aggregator is simulated considering the relation between distribution system operator’s (DSO’s) operation modes and its equivalent market transactive price. Besides the traditional mixed-integer linear programming (MILP) model, the active reconfiguration model of DSOs based on mixed-integer second-order conic programming (MI-SOCP) is proposed to rearrange its operation switch status and elaborate its operation cost according to the market transaction. Multi-period optimal operation modes could be obtained through an HGDC-based iteration process by coordinating the transmission system operator (TSO) with DSOs and considering the market energy equilibrium and reserve requirements for security considerations. Karush-Kuhn-Tucker (KKT) conditions are used to testify the optimality and convergence of the bi-level model in theory. The T5-3D33 case is employed to illustrate the efficiency of the proposed model and method.