Ho soon Yang

Dr. Ho soon Yang


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2013 in Optics Express
Verified
Journal Article
Open access
PDF file
HRHyug-Gyo Rhee
Hyug-Gyo Rhee
Young-Sik GhimYoung-Sik Ghim
Young-Sik Ghim
JLJoohyung Lee
Joohyung Lee
HYHo soon Yang
Ho soon Yang
YLYun-Woo Lee
Yun-Woo Lee
A lateral shearing interferometer has an advantage over previous wavefront measuring interferometers since it requires no reference. Therefore the lateral shearing interferometer can be a powerful solution to measure a freeform surface. It, however, has some issues to be resolved before it can be implemented. One of them is the orthogonality problem between two shearing directions in LSI. Previous wavefront reconstruction algorithms assume that the shearing directions are perfectly orthogonal to each other and lateral shear is obtained simultaneously in the sagittal and tangential directions. For practical LSI, however, there is no way to guarantee perfect orthogonality between two shearing directions. Motivated by this, we propose a new algorithm that is able to compensate the rotational inaccuracy. The mathematical model is derived in this paper. Computer simulations and experiments are also displayed to verify our algorithm.

20 November 2014 in Journal of the Korean Physical Society
Verified
Journal Article
Closed access
PDF file
HRHyug-Gyo Rhee
Hyug-Gyo Rhee
HKHagyong Kihm
Hagyong Kihm
HYHo soon Yang
Ho soon Yang
YGYoung-Sik Ghim
Young-Sik Ghim
YLYun-Woo Lee
Yun-Woo Lee
JLJoohyung Lee
Joohyung Lee

28 September 2020 in Applied Optics
Verified
Journal Article
Closed access
GKGoeun Kim
Goeun Kim
ISIn-Ung Song
In-Ung Song
JPJune Gyu Park
June Gyu Park
HKHagyong Kihm
Hagyong Kihm
HYHo soon Yang
Ho soon Yang
The Ritchey–Common test is a widely used method for testing flat mirrors with a larger reference spherical mirror. However, with the increase in the size of the flat mirror, the fabrication of the spherical mirror becomes more time consuming and expensive. In this study, we developed a novel technique to test a large flat mirror with a smaller reference sphere using a dual subaperture stitching (DSS) method. One part of the DSS technique is a modified Ritchey–Common test, which uses a reference sphere smaller than the flat mirror. The other part involves scanning along the centerline of the flat mirror. The former can be used to determine the surface form error (SFE), except for rotationally symmetric components, such as power and spherical aberrations, which can be measured by the latter. To perform the stitching process using a smaller reference sphere, the flat mirror was repeatedly rotated by a fixed angular step. One of the advantages of the rotation of the flat mirror is that it can be used to identify the errors resulting from the reference sphere, which do not vary during the rotation of the flat mirror. We verified the DSS method using a 152 mm diameter optical flat mirror and determined the root-mean-square (rms) measurement error to be only 0.2 nm, which was comparable to the error of the full-aperture interferometric measurement. In addition, we tested a 1.2 m diameter flat mirror with a reference sphere with an aperture of 0.8 m and measured its SFE to be 11.9 ± 0.5 n m rms.

18 February 2020 in Journal of the Korean Physical Society
Verified
Journal Article
Closed access
PDF file
OKOhgan Kim
Ohgan Kim
BLBong Ju Lee
Bong Ju Lee
HRHyug-Gyo Rhee
Hyug-Gyo Rhee
YLYun-Woo Lee
Yun-Woo Lee
HYHo soon Yang
Ho soon Yang
We present a path-dependent phase unwrapping algorithm with the dual-path scheme. The proposed algorithm removes the inconsistency between the true phase a

7 February 2022 in Journal of the Korean Physical Society
Verified
Journal Article
Open access
PDF file
HKHagyong Kihm
Hagyong Kihm
YLYun-Woo Lee
Yun-Woo Lee
HYHo soon Yang
Ho soon Yang
SKSeonghui Kim
Seonghui Kim
DLDeog-Gyu Lee
Deog-Gyu Lee
CAS500-1 (Compact Advanced Satellite 500-1) launched in Mar. 2021 is the first Korean ground observation satellite localizing the entire mirror development, especially the primary mirror M1. M1 is a lightweight concave mirror with a diameter of 0.6 m, and it has 3 square bosses at the rim for flexure mounting. We present the whole development procedure of the flight model M1, including the optomechanical design, fabrication, environmental tests, and a coordinate mapping method for alignment and integration.

22 November 2021 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JLJae-Cheul Lee
Jae-Cheul Lee
HCHyun-Ju Cho
Hyun-Ju Cho
HYHo soon Yang
Ho soon Yang
The main factors that limit the performance of ring laser gyroscopes include random walk, quantization noise, and bias stability. The first two factors determine the alignment time for navigation systems, and the bias stability error can result in long-term accuracy. We show that a phase wrapping/unwrapping algorithm, which has been widely used in interferometry fields, can be utilized to remove lock-in and quantization errors by implementing a zero-lock-in ring laser gyroscope. Furthermore, the performance of the ring laser gyroscope with no mechanical dither is described, and mirror dithering, instead of mechanical dithering, is proposed.