Omnia A. Ali El-Naem

Prof. Dr. Omnia A. Ali El-Naem


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
CEChristine M. El-Maraghy
Christine M. El-Maraghy
OEOla M. El-Borady
Ola M. El-Borady
OEOmnia A. Ali El-Naem
Omnia A. Ali El-Naem
The presence of antibiotic traces in the aquatic system due to the inefficient treatment of the pharmaceutical wastewater represented threats, such as bioaccumulation and antibiotic-resistance, to the environment and human health. Accordingly, for the first time, the current work utilized the photocatalytic degradation and the adsorption approach for Levofloxacin (LEVO) in pharmaceutical wastewater using new designed nano aspects. Therefore, spherical Zinc oxide nanoparticles (ZnONP) sized 17 nm and ultrathin sheet-like structure graphene oxide nanosheets (GONS) with layer thickness ~5 nm were fabricated separately or in a combination between them then characterized via Transmission Electron Microscope (TEM), Scanning Electron Microscope (SEM), X-Ray Diffraction (XRD), Fourier Transforms Infrared Spectroscopy (FTIR), absorption spectra (UV-Vis) and Brunauer-Emmett-Teller (BET). Additionally, several parameters were investigated to evaluate the potential of the removal process, such as pH, the exposure time to UV radiation, the type and concentration of the nanoparticles (NPs) and the initial concentration of the drug using a mixed fractional factorial design. The most effective parameter for LEVO removal was the NPs type followed by the initial drug concentration. Furthermore, an RP-HPLC/UV method was developed and validated for measuring the percentage of removal for LEVO drug. The highest percentage removal for both 50 and 400 µg mL−1 LEVO was 99.2% and 99.6%, respectively, which was achieved using ZnONP/GONS combination at pH 9 ± 0.05 and UV light exposure time 120 min. In addition, the negative antibacterial activity of the treated wastewater sample confirmed the drug removal. The established protocol was successfully applied on wastewater samples collected from a pharmaceutical company that encouraged researchers to mainstream this design to be applied on other pharmaceutical wastewater drugs.

1 February 2015 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
AMAzza Aziz Moustafa
Azza Aziz Moustafa
HSHesham Salem
Hesham Salem
MHMaha Hegazy
Maha Hegazy
OEOmnia A. Ali El-Naem
Omnia A. Ali El-Naem

1 February 2016 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
AMAzza A. Moustafa
Azza A. Moustafa
MHMaha A. Hegazy
Maha A. Hegazy
DMDalia Mohamed
Dalia Mohamed
OEOmnia A. Ali El-Naem
Omnia A. Ali El-Naem

25 February 2019 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
PDF file
AMAzza A. Moustafa
Azza A. Moustafa
MHMaha A. Hegazy
Maha A. Hegazy
DMDalia Mohamed
Dalia Mohamed
OEOmnia A. Ali El-Naem
Omnia A. Ali El-Naem
Nanosized adsorbents when used in potentiometric methods of analysis usually show better performance rather than the traditional potentiometric approach; this is attributed to the high specific surface area of the nanomaterial used in addition to the lack of internal diffusion resistance, thus improving their adsorption capacity. In the presented work, a rapid and sensitive potentiometric determination of chlorpheniramine maleate (CPM) and pseudoephedrine hydrochloride (PSE) in pure form, in pharmaceutical preparation, and in biological fluid was developed based on functionalized magnetic nanoparticles (Fe3O4). This strategy was compared with the classical potentiometric strategy. Three types of sensors were constructed using phosphotungstic acid (PTA),β-cyclodextrin (β-CD), andβ-cyclodextrin-conjugated Fe3O4magnetic nanoparticles for the potentiometric determination of each of CPM and PSE. The prepared sensors were characterized in regards to their composition, life duration, working pH range, and response time. The sensors have demonstrated promising selectivity to CPM and PSE in the presence of pharmaceutical formulation excipients, plasma matrix, and a diversity of both organic and inorganic interfering materials. The developed sensors have displayed good responses. Statistical comparison of the achieved results with a reported method has revealed no significant difference regarding both accuracy and precision.

1 August 2018 in JPC – Journal of Planar Chromatography – Modern TLC
Verified
Journal Article
Closed access
AMAzza A. Moustafa
Azza A. Moustafa
MHMaha A. Hegazy
Maha A. Hegazy
DMDalia Mohamed
Dalia Mohamed
OEOmnia A. Ali El-Naem
Omnia A. Ali El-Naem
Simple, accurate, precise, sensitive, and validated high-performance liquid chromatography (HPLC) and thin-layer chromatography (TLC)‒densitometric methods were developed for the simultaneous determination of chlorpheniramine maleate (CPM), pseudoephedrine HCl (PSE), and ibuprofen (IBF) in tablet dosage form. In method A, reversed-phase (RP)-HPLC analysis was performed on Zorbax C8 column (150 mm × 4.6 mm, 5 μm particle size i.d.), using a mobile phase consisting of methanol–acetonitrile–distilled water (pH 4) using orthophosphoric acid in the ratio (80:10:10, v/v) and flow rate of 0.7 mL min−1. Quantification was achieved with ultraviolet (UV) detection at 220 nm. In method B, TLC analysis was carried out on an aluminum-backed sheet of silica gel 60 F254 layer using ethyl acetate‒methanol‒ammonia (8:2:0.8, v/v) as the mobile phase. Quantification was carried out with UV detection at 262 nm. The validation of the proposed methods was applied according to the International Conference on Harmonization (ICH) guidelines. The suggested methods were successfully applied for the determination of the cited drugs in bulk powder and commercial dosage form.

2 November 2013 in Analytical Chemistry Letters
Verified
Journal Article
Closed access
AMAzza Aziz Moustafa
Azza Aziz Moustafa
HSHesham Salem
Hesham Salem
MHMaha Hegazy
Maha Hegazy
OEOmnia A. Ali El-Naem
Omnia A. Ali El-Naem
Simple, accurate, sensitive, selective and validated UV spectrophotometric univariate and multivariate methods were developed for determination of Buflomedil (BFM) in presence of BFM degradation products (BFM Deg). The univariate methods includes mean centering of ratio spectra (MCR), ratio difference spectrophotometric method (RDSM) and H-point standard addition method (HPSAM); the first one used the amplitude at 235.7 nm, the second utilized the difference in amplitudes at 250 nm and 282 nm; while, the third method utilized the absorbance values at 247 and 282.4 nm. Linearity was obtained for the proposed methods in the ranges of 10–100 µgmL-1. The percentage recoveries were 100.06±0.963, 100.17±0.962 and 100.90±0.667 for the three methods in a respective order. Multivariate methods involves the application of three chemometric techniques, and classical least square (CLS) principal component regression (PCR) and partial least-squares regression (PLS), which were used for the simultaneous determination of the BFM and its degradation products. The results obtained from the proposed methods, together with the reported one, were statistically compared using one-way analysis of variance (ANOVA). These methods are suitable as stability indicating methods for the determination of BFM in presence of its degradation products either in bulk powder or in pharmaceutical formulations.