Probe-based confocal laser endomicroscopy (pCLE) is a subcellular in vivo imaging technique that generates diagnostic images revealing malignant structural modifications in epithelial tissues. In the clinical diagnosis of probe confocal laser endomicroscopy (pCLE), the image background generally has the problems of dynamic blur or information loss, which is not conducive to achieving high-resolution and clear pCLE imaging. In recent years, deep learning technology has achieved remarkable results in image deblurring. For the task of recovering high-resolution pCLE images, the current methods still suffer from the following drawbacks: it is difficult to choose a strategy to make CNN converge at a deeper level and mainstream methods cannot handle the complex balance between spatial details and high-level feature information well when reconstructing clear images. In order to solve the problem, we propose a new cross-channel attention, multistage, high-resolution pCLE image deblurring structure. This methodology improves the supervised attention mechanism, enhances the ability of feature extraction and fusion capabilities, and improves the quality of image deblurring by adding cross-channel attention module (CAM) into the multistage neural networks’ architecture. The experimental results show that the average peak signal-to-noise ratio (PSNR) of the proposed model on the dataset is as high as 29.643 dB, and the structural similarity (SSIM) reaches 0.855. This method is superior to the prior algorithms in the visualization of recovered images, and the edge and texture details of the restored pCLE images are clearer.
A dual-parameter optical fiber sensor for measuring the magnetic field and temperature based on the Fabry–Perot interferometer (FPI) and magnetic polymer film was proposed and designed, realizing dual-parameter measurement of temperature and the magnetic field. The sensor uses the excellent elasticity and thermal expansion coefficient of PDMS and the magnetostrictive effect of Fe3O4 magnetic polymer film to provide magnetic field and temperature detection while maintaining good reusability, achieving a magnetic field sensitivity and temperature sensitivity of 69 pm/mT and 390 pm/K, respectively. The sensor has the advantages of a low cost, a simple manufacturing process, good linearity, and a sensitive temperature response. It has broad application prospects in medicine, geography, aerospace, and other fields.
We propose a novel silicon-based THz Mach–Zehnder interferometer (MZI) biosensor integrated with a polarization splitter and rotator (PSR). An optimized PSR is positioned at the input of the MZI, enabling arbitrary polarization inputs to be converted into the same TE mode, which eliminates the dependence of conventional MZI sensors on the input light polarization. The PSR structural parameters are optimized using 3D-FDTD simulations to achieve phase matching, and the calculation results show that efficient TM–TE-polarization conversion occurs along a coupling length of 22.9 mm. Furthermore, the PSR achieves a maximum TE-mode extinction ratio of −30.1 dB and a polarization conversion efficiency of 82.33% in the 0.44 to 0.45 THz range, effectively maintaining the polarization consistency of light entering the MZI. Meanwhile, the characteristic frequency shows a regular blue shift with increasing external refractive index, and the final results demonstrate that the designed MZI biosensor achieves a high sensitivity of 13,215.81 nm/RIU near the center frequency of 0.45 THz. All results presented in this work are obtained through numerical simulations, and experimental validation as well as analyte-concentration-dependent refractive index characterization will be addressed in future studies. To sum up, we propose a high-sensitivity terahertz MZI biosensor featuring a PSR with an on-chip integration scheme, which supports arbitrary polarization inputs and offers a highly integrated solution for specific detection in biomedicine.