Background/Objectives: Operator experience, the implementation of low frame rates during both fluoroscopy and digital subtraction angiography (DSA), and the use of modern angiographic systems are essential for maintaining diagnostic image quality while minimizing ionizing radiation exposure during stent-assisted endovascular treatment of intracranial aneurysms. At the study center, a low-dose protocol is employed, using the lowest available fluoroscopy frame rate (3.125 frames per second) and a nominal acquisition rate of 2 frames per second for DSA, three-dimensional (3D) rotational angiography, 2D/3D mapping, and roadmapping. Methods: A retrospective analysis was performed on 132 stent-assisted procedures conducted at a single tertiary center between 2018 and 2024. For each procedure, data were collected for dose-area product (DAP), reference air kerma (Ka,r), fluoroscopy time (FT), and the total number of DSA frames. Local diagnostic reference levels (DRLs; 75th percentile [P75]) and typical values (50th percentile [P50]) were established and compared with values reported in the literature. Results: For all patients the P75 values, representing DRLs, were 19.89 Gy·cm2 for DAP, 332 mGy for Ka,r, 25 min 32 s for FT, and 354 DSA frames. The P50 values were 13.71 Gy·cm2 for DAP, 219.5 mGy for Ka,r, 20 min 36 s for FT, and 277 DSA frames. Conclusions: In this single-center cohort, dose metrics for stent-assisted coil embolization were within the lower range of published values. Cross-study comparisons remain descriptive and require cautious interpretation. The proposed local DRLs may support quality assurance, dose optimization, and patient safety in similar clinical settings. Further multicenter and multi-operator studies are necessary to assess transferability and applicability beyond coil-only procedures. Limitations include the retrospective single-center design (single operator) and the lack of a contemporaneous control group and formal image-quality/outcome assessment.

21 January 2026 in Biomedicines
Verified
Journal Article
Open access
PDF file
MSMariusz Sowa
Mariusz Sowa
JSJoanna Sowa
Joanna Sowa
KWKamil Adam Węglarz
Kamil Adam Węglarz
MBMaciej Budzanowski
Maciej Budzanowski
Background/Objectives: Optimizing routine neurointerventional workflow and minimizing exposure to ionizing radiation during coil-only endovascular treatment of intracranial aneurysms depend on operator experience, reduced frame rates during both fluoroscopy and digital subtraction angiography (DSA), and the use of advanced angiographic systems. The low-dose protocol implemented in this study used the lowest available fluoroscopy frame rate (3.125 frames per second [fps]) and a nominal acquisition rate of 2 fps (actual = 2.45 fps) for DSA, three-dimensional (3D) rotational angiography, two-dimensional (2D)/3D mapping, and roadmapping. Methods: This retrospective analysis encompassed 245 coil-only procedures performed at a single tertiary center from 2018 to 2024. Data collected for each procedure included dose-area product (DAP), reference air kerma (Ka,r), fluoroscopy time (FT), and the total number of DSA frames. Local diagnostic reference levels (DRLs; 75th percentile [P75]) and typical values (50th percentile [P50]) were determined and descriptively compared with values reported in the literature. Results: The P75 values, representing DRLs, were 22.4 Gy·cm2 for DAP (literature range, 123–272.8 Gy·cm2), 268 mGy for Ka,r (1171–4240 mGy), 18 min 56 s for FT, and 285 DSA frames. The P50 values were 13.8 Gy·cm2 for DAP (78.7–179.0 Gy·cm2), 196 mGy for Ka,r (801–2804 mGy), 13 min 25 s for FT, and 208 DSA frames. Conclusions: In this single-center cohort, dose metrics for coil-only intracranial aneurysm treatment were within the lower range of published values. Cross-study comparisons are descriptive and require cautious interpretation. The proposed local DRLs may support quality assurance, dose optimization, and patient safety in comparable clinical settings. Further multi-center and multi-operator studies are warranted to evaluate transferability and applicability beyond coil-only procedures.