Purpose: Incorrect assessment of tissue perfusion carries a significant risk of complications in surgery. The use of near-infrared (NIR) fluorescence imaging with Indocyanine Green (ICG) presents a possible solution. However, only through quantification of the fluorescence signal can an objective and reproducible evaluation of tissue perfusion be obtained. This narrative review aims to provide an overview of the available quantification methods for perfusion assessment using ICG NIR fluorescence imaging and to present an overview of current clinically utilized software implementations. Methods: PubMed was searched for clinical studies on the quantification of ICG NIR fluorescence imaging to assess tissue perfusion. Data on the utilized camera systems and performed methods of quantification were collected. Results: Eleven software programs for quantifying tissue perfusion using ICG NIR fluorescence imaging were identified. Five of the 11 programs have been described in three or more clinical studies, including Flow® 800, ROIs Software, IC Calc, SPY-Q™, and the Quest Research Framework®. In addition, applying normalization to fluorescence intensity analysis was described for two software programs. Conclusion: Several systems or software solutions provide a quantification of ICG fluorescence; however, intraoperative applications are scarce and quantification methods vary abundantly. In the widespread search for reliable quantification of perfusion with ICG NIR fluorescence imaging, standardization of quantification methods and data acquisition is essential.
Purpose: Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) is gaining popularity for the quantification of tissue perfusion, including foot perfusion in patients with lower extremity arterial disease (LEAD). However, the absolute fluorescence intensity is influenced by patient—and system-related factors limiting reliable and valid quantification. To enhance the quality of quantitative perfusion assessment using ICG NIR fluorescence imaging, normalization of the measured time-intensity curves seems useful. Materials and Methods: In this cohort study, the effect of normalization on 2 aspects of ICG NIR fluorescence imaging in assessment of foot perfusion was measured: the repeatability and the region selection. Following intravenous administration of ICG, the NIR fluorescence intensity in both feet was recorded for 10 mins using the Quest Spectrum platform ® . The effect of normalization on repeatability was measured in the nontreated foot in patients undergoing unilateral revascularization preprocedural and postprocedural (repeatability group). The effect of normalization on region selection was performed in patients without LEAD (region selection group). Absolute and normalized time-intensity curves were compared. Results: Successful ICG NIR fluorescence imaging was performed in 54 patients (repeatability group, n = 38; region selection group, n = 16). For the repeatability group, normalization of the time-intensity curves displayed a comparable inflow pattern for repeated measurements. For the region selection group, the maximum fluorescence intensity (Imax) demonstrated significant differences between the 3 measured regions of the foot ( P = .002). Following normalization, the time-intensity curves in both feet were comparable for all 3 regions. Conclusion: This study shows the effect of normalization of time-intensity curves on both the repeatability and region selection in ICG NIR fluorescence imaging. The significant difference between absolute parameters in various regions of the foot demonstrates the limitation of absolute intensity in interpreting tissue perfusion. Therefore, normalization and standardization of camera settings are essential steps toward reliable and valid quantification of tissue perfusion using ICG NIR fluorescence imaging.
Introduction: Glucagon like peptide-2 is synthesized from enteroendocrine L cells primarily located in the ileum and large intestine. GLP-2 stimulates crypt cell proliferation, increases intestinal blood flow, enhances gut barrier function, induces mucosal healing, and exerts an anti-apoptotic effect. Due to these effects GLP-2 is used in the treatment of short bowel syndrome (SBS). Areas covered: The aim of this systematic review was to provide information on the potential risk of intestinal neoplasia in patients receiving treatment with GLP-2. The literature search was performed independently by two authors in the following databases; Pubmed, Embase, Scopus, Web of Science and Cochrane. Expert commentary: This systematic review indicated that treatment with GLP-2(1–33) up to 30 months in humans without any known pre-existing cancer did not confer an increased risk of intestinal neoplasia in patients or animals. However, due to the small amount of patients studied it is premature to reach any final conclusions about GLP-2 – induced neoplasia. GLP-2(1–33) treatment in animals with a pre-induced cancer showed that GLP-2(1–33) may promote growth of existing neoplasia.