Nikolaj Nerup

Dr. Nikolaj Nerup

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2016 in Langenbeck's Archives of Surgery
Verified
Journal Article
Closed access
PDF file
NNNikolaj Nerup
Nikolaj Nerup
HAHelene Schou Andersen
Helene Schou Andersen
RARikard Ambrus
Rikard Ambrus
RSRune Broni Strandby
Rune Broni Strandby
MSMorten Bo Svendsen
Morten Bo Svendsen
MAMichael Patrick Achiam
Michael Patrick Achiam

26 January 2023 in Langenbeck's Archives of Surgery
Verified
Journal Article
Open access
PDF file
PHPim Van Den Hoven
Pim Van Den Hoven
JOJens Thomas Fredrik Osterkamp
Jens Thomas Fredrik Osterkamp
NNNikolaj Nerup
Nikolaj Nerup
MSM B S Svendsen
M B S Svendsen
AVAlexander Vahrmeijer
Alexander Vahrmeijer
MAMichael Patrick Achiam
Michael Patrick Achiam
Purpose: Incorrect assessment of tissue perfusion carries a significant risk of complications in surgery. The use of near-infrared (NIR) fluorescence imaging with Indocyanine Green (ICG) presents a possible solution. However, only through quantification of the fluorescence signal can an objective and reproducible evaluation of tissue perfusion be obtained. This narrative review aims to provide an overview of the available quantification methods for perfusion assessment using ICG NIR fluorescence imaging and to present an overview of current clinically utilized software implementations. Methods: PubMed was searched for clinical studies on the quantification of ICG NIR fluorescence imaging to assess tissue perfusion. Data on the utilized camera systems and performed methods of quantification were collected. Results: Eleven software programs for quantifying tissue perfusion using ICG NIR fluorescence imaging were identified. Five of the 11 programs have been described in three or more clinical studies, including Flow® 800, ROIs Software, IC Calc, SPY-Q™, and the Quest Research Framework®. In addition, applying normalization to fluorescence intensity analysis was described for two software programs. Conclusion: Several systems or software solutions provide a quantification of ICG fluorescence; however, intraoperative applications are scarce and quantification methods vary abundantly. In the widespread search for reliable quantification of perfusion with ICG NIR fluorescence imaging, standardization of quantification methods and data acquisition is essential.

4 May 2019 in Langenbeck's Archives of Surgery
Verified
Journal Article
Closed access
PDF file
JRJonas Hedelund Rønn
Jonas Hedelund Rønn
NNNikolaj Nerup
Nikolaj Nerup
RSRune Broni Strandby
Rune Broni Strandby
MSMorten Bo Svendsen
Morten Bo Svendsen
RARikard Ambrus
Rikard Ambrus
MAMichael Patrick Achiam
Michael Patrick Achiam

3 March 2022 in Journal of Endovascular Therapy
Verified
Journal Article
Open access
PHPim Van Den Hoven
Pim Van Den Hoven
FTFloris Tange
Floris Tange
JVJurrian Van Der Valk
Jurrian Van Der Valk
NNNikolaj Nerup
Nikolaj Nerup
HPHein Putter
Hein Putter
Joost Van Der VorstJoost Van Der Vorst
Joost Van Der Vorst
Purpose: Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) is gaining popularity for the quantification of tissue perfusion, including foot perfusion in patients with lower extremity arterial disease (LEAD). However, the absolute fluorescence intensity is influenced by patient—and system-related factors limiting reliable and valid quantification. To enhance the quality of quantitative perfusion assessment using ICG NIR fluorescence imaging, normalization of the measured time-intensity curves seems useful. Materials and Methods: In this cohort study, the effect of normalization on 2 aspects of ICG NIR fluorescence imaging in assessment of foot perfusion was measured: the repeatability and the region selection. Following intravenous administration of ICG, the NIR fluorescence intensity in both feet was recorded for 10 mins using the Quest Spectrum platform ® . The effect of normalization on repeatability was measured in the nontreated foot in patients undergoing unilateral revascularization preprocedural and postprocedural (repeatability group). The effect of normalization on region selection was performed in patients without LEAD (region selection group). Absolute and normalized time-intensity curves were compared. Results: Successful ICG NIR fluorescence imaging was performed in 54 patients (repeatability group, n = 38; region selection group, n = 16). For the repeatability group, normalization of the time-intensity curves displayed a comparable inflow pattern for repeated measurements. For the region selection group, the maximum fluorescence intensity (Imax) demonstrated significant differences between the 3 measured regions of the foot ( P = .002). Following normalization, the time-intensity curves in both feet were comparable for all 3 regions. Conclusion: This study shows the effect of normalization of time-intensity curves on both the repeatability and region selection in ICG NIR fluorescence imaging. The significant difference between absolute parameters in various regions of the foot demonstrates the limitation of absolute intensity in interpreting tissue perfusion. Therefore, normalization and standardization of camera settings are essential steps toward reliable and valid quantification of tissue perfusion using ICG NIR fluorescence imaging.


13 December 2017 in Expert Review of Gastroenterology & Hepatology
Verified
Journal Article
Closed access
LRLinea Landgrebe Ring
Linea Landgrebe Ring
NNNikolaj Nerup
Nikolaj Nerup
PJPalle Bekker Jeppesen
Palle Bekker Jeppesen
LSLars Bo Svendsen
Lars Bo Svendsen
MAMichael Patrick Achiam
Michael Patrick Achiam
Introduction: Glucagon like peptide-2 is synthesized from enteroendocrine L cells primarily located in the ileum and large intestine. GLP-2 stimulates crypt cell proliferation, increases intestinal blood flow, enhances gut barrier function, induces mucosal healing, and exerts an anti-apoptotic effect. Due to these effects GLP-2 is used in the treatment of short bowel syndrome (SBS). Areas covered: The aim of this systematic review was to provide information on the potential risk of intestinal neoplasia in patients receiving treatment with GLP-2. The literature search was performed independently by two authors in the following databases; Pubmed, Embase, Scopus, Web of Science and Cochrane. Expert commentary: This systematic review indicated that treatment with GLP-2(1–33) up to 30 months in humans without any known pre-existing cancer did not confer an increased risk of intestinal neoplasia in patients or animals. However, due to the small amount of patients studied it is premature to reach any final conclusions about GLP-2 – induced neoplasia. GLP-2(1–33) treatment in animals with a pre-induced cancer showed that GLP-2(1–33) may promote growth of existing neoplasia.