Retinal transplantation offers promise for restoring vision in advanced retinal degeneration. However, manual delivery of retinal sheets is often hindered by imprecise placement and collateral tissue damage resulting from instrument instability. We introduce a novel, 3D-printed, motorized retinal sheet injector designed to enhance placement accuracy and minimize tissue injury. The motorized injector features an Arduino-controlled foot pedal with three discrete actuator positions (“Min”, “Mid”, “Max”). When compared via frame-by-frame motion analysis, the motorized system reduced tip variance by approximately threefold over manual methods. In addition, in in vitro gelatin trials, the motorized injector achieved significantly higher placement accuracy versus the manual injector, which suffered from occasional complete misplacements. The novel motorized retinal sheet injector markedly improves stability and placement accuracy relative to manual methods, potentially reducing complications associated with subretinal delivery. Safer subretinal delivery can pave the way for innovative research and advanced treatment for retinal disease.
Purpose: To determine the repeatability of a clinical pupillometer in healthy participants with a 5 and 30 − minute test − retest break for both Swinging-Flashlight and Low-High Luminance approach. Methods: 20 healthy participants (mean age: 27 years ±5; 9 females) placed their heads into the device’s headrest and fixated a central spot. A Swinging-Flashlight approach evoked a pupillary light reflex, stimulating alternatingly 8 times each eye by a brief diffuse white light flash followed by a continuous measurement of constriction and dilation of the direct and consensual pupils. For the Low-High Luminance setting, continuous measurements of pupil diameters for a 5 second low luminance display followed by a 5 second high luminance white light. Pupillary light reflex parameters for each test and each eye were calculated by the device. Repeatability was investigated after a 5-minute break time and during a control experiment for 21 participants after a 30-minute break for each approach in counterbalanced order using Bland-Altman analysis. Results: Overall, many parameters for both Swinging-Flashlight and Low-High Luminance approach showed retest biases for all pupil light reflex parameters after a 5-minute test-retest break. These biases were almost completely reduced after a 30-minute break between test and retest for both approaches. The test-retest variabilities as expressed using the Coefficient of Repeatability was reduced after 30-minutes for the majority of the Low-High Luminance results but not for results of the Swinging-Flashlight method. Conclusions: Clinical pupillometry includes the Swinging Flashlight Test (SFL) and Low-High Luminance assays. In SFL, many pupillary dynamic metrics showed test-retest bias at a 5-minute interval, whereas relative afferent pupillary defect (RAPD) measurements remained unbiased at both 5 and 30-minute intervals. Similarly, Low-High Luminance testing showed minimal bias after 30 minutes but exhibited bias at the 5-minute interval. Thus, when evaluating multiple pupillary parameters in scientific or clinical settings, RAPD is less susceptible to bias, while other metrics require longer intervals between testing and retesting.