This study investigated the relative proportion of motor-unit action potentials that are uniquely represented in the simulated and experimental surface electromyogram (EMG). Two hundred motor units were simulated in a cylindrical anatomical system. Action potentials for each motor unit were generated with a model and then compared with those of other motor units. Pairs of motor units were considered indistinguishable and the motor units not uniquely represented in the surface EMG, when the difference in the mean energy for the pair of potentials was <5%. The anatomical conditions and recording configurations had a substantial influence on the percentage of motor units that could be uniquely identified in the simulated EMG. For example, a single monopolar channel could discriminate only 3.4% of motor units in the simulated population, whereas a system with 81 Laplacian channels arranged in a grid could discriminate 83.8% of the motor units under the same conditions. The simulation results were confirmed with populations of motor units recorded experimentally from the abductor digiti minimi muscle of eight healthy men. Furthermore, the relative proportion of uniquely identified motor units in the simulated signal was only moderately related to motor-unit size and distance from the electrodes. These results indicate the upper limit for detection of individual motor units from the surface EMG and show that a few channels of surface EMG recordings are not sufficient to study single motor units. The noninvasive identification of motor units from the surface EMG requires the use of multiple channels of information.
Objective: The use of linear or bi-dimensional electrode arrays for surface EMG detection (HD-sEMG) is gaining attention as it increases the amount and reliability of information extracted from surface EMG. However, the complexity of the setup and the encumbrance of HD-sEMG hardware currently limits its use in dynamic conditions. The aim of this work was to develop a miniaturized, wireless, and modular HD-sEMG acquisition system for applications requiring high portability and robustness to movement artifacts. Methods: A system with scalable architecture was developed. Its core is a miniaturized 32-channel amplifier (Sensor Unit - SU) sampling at 2048sps/ch with 16bit resolution and wirelessly transmitting data to a PC or a mobile device. Each SU is a node of a Body Sensor Network for the synchronous acquisition from different muscles. Results: The device is small (3.4cm x 3cm x 1.5cm), light (16.7g), and can be connected directly to the electrodes thus avoiding the customary, wired setup. It allows to detect HD-sEMG signals with an average RMS noise of 1.8 $\mu$ V and high performance in terms of rejection of power-line interference and motion artefacts. Tests performed on two prototypes showed no data loss in a 22m range and a $\pm$ 500 $\mu$ s maximum synchronization delay. Conclusions: Data collected in a wide spectrum of experimental conditions confirmed the functionality of the designed architecture and the quality of the acquired signals. Significance: By simplifying the experimental setup, reducing the hardware encumbrance, and improving signal quality during dynamic contractions, the developed system opens new perspectives in the use of HD-sEMG in applied and clinical settings.