This paper introduces a newly developed steel-fiber-reinforced polymer (FRP) composite bar (SFCB) and proposes the ideal configuration based on a large number of exploratory tests on handmade products. Based on factory production of SFCB, uniaxial tensile tests and cyclic tensile tests were conducted to determine the initial elastic modulus, postyield stiffness, yield strength, ultimate strength, unloading stiffness, and residual deformation. Test results showed that the stress-strain curve of the SFCB was bilinear before the fiber fractures. After the inner steel yielded, the SFCB showed a stable postyield stiffness, small residual deformation, and good reparability. Because the theoretical model for the stress-strain curve of SFCB under a uniaxial load based on the mixture rule had large error with data from cyclic tests, the corresponding restoring force model under cyclic tensile loading was constructed by statistical analysis of the stress-strain test curve under cyclic tension. The generated restori...
1 January 2017 in Construction and Building Materials
A steel-fiber reinforced polymer (FRP) composite bar (SFCB) is a novel reinforcing rebar made of an inner steel bar and outer FRP integrated in a pultrusion process. To promote the application of this new reinforcing rebar, this paper explores the mechanical properties of SFCBs and the performance of SFCB-reinforced concrete structures. Test results of SFCBs under uniaxial and cyclic tensile loading show that SFCB has a high elastic modulus, a stable post-yield modulus and a high ultimate strength. The tensile characteristics of SFCBs calculated according to the mixture law are found to be in good agreement with test results. A direct pullout test between SFCBs and concrete was conducted. The failure modes included SFCB pullout before or after inner steel bar yielded, which depended on factors like the steel/FRP ratio, effective bond length, and concrete strength. With its high-performance, especially with regard to anti-corrosion, and low cost, SFCBs are an ideal near-surface mounted (NSM) material to strengthen concrete beams. Experimental results show that NSM-SFCB strengthening can significantly increase both the section stiffness of the flexural members in the service stage and the bearing capacity in the ultimate stage. Concrete columns reinforced by SFCBs under horizontal cyclic loading were also tested, and the results show that concrete columns reinforced by SFCBs possess high initial stiffness, acceptable bearing capacity and good ductility. More importantly, SFCB columns had an obvious post-yield stiffness, which resulted in smaller residual displacement and, therefore, better post-earthquake reparability.
Steel-fiber-reinforced polymer (FRP) composite bars (SFCBs) are a novel reinforcement for concrete structures. Because of the FRP’s linear elastic characteristic and high ultimate strength, they can achieve a stable postyield stiffness even after the inner steel bar has yielded, which subsequently enables a performance-based seismic design to easily be implemented. In this study, lateral cyclic loading tests of concrete columns reinforced either by SFCBs or by ordinary steel bars were conducted with axial compression ratios of 0.12. The main variable parameters were the FRP type (basalt or carbon FRP) and the steel/FRP ratio of the SFCBs. The test results showed the following: (1) compared with ordinary RC columns, SFCB-reinforced concrete columns had a stable postyield stiffness after the SFCB’s inner steel bar yielded; (2) because of the postyield stiffness of the SFCB, the SFCB-reinforced concrete columns exhibited less column-base curvature demand than ordinary RC columns for a given column cap latera...