The estimation of the critical current ( Ic ) and AC losses of high-temperature superconductor devices through modeling and simulation requires the knowledge of the critical current density ( Jc ) of the superconducting material. This Jc is in general not constant and depends both on the magnitude ( Bloc ) and the direction ( θ , relative to the tape) of the local magnetic flux density. In principle, Jc ( Bloc , θ ) can be obtained from the experimentally measured critical current Ic ( Ba , θ ), where Ba is the magnitude of the applied magnetic field. However, for applications where the superconducting materials experience a local field that is close to the self-field of an isolated conductor, obtaining Jc ( Bloc , θ ) from Ic ( Ba , θ ) is not a trivial task. It is necessary to solve an inverse problem to correct for the contribution derived from the self–field. The methods presented in the literature comprise a series of approaches dealing with different degrees of mathematical regularization to fit the parameters of preconceived nonlinear formulas by means of brute force or optimization methods. In this contribution, we present a parameter-free method that provides excellent reproduction of experimental data and requires no human interaction or preconception of the Jc dependence with respect to the magnetic field. In particular, it allows going from the experimental data to a ready-to-run Jc ( Bloc , θ ) model in a few minutes.
The article is devoted to issues related to improving energy efficiency in public buildings. The adopted research method is based on measurements of energy quality, which are the basis for the development of a plan to increase the energy efficiency of buildings. The article describes the results of measurements carried out for a selected office building, characterized by a cyclical load profile. The energy quality parameters were measured, which were referenced to the currently valid standards. As part of the study, a plan for saving and increasing the energy efficiency of the building and implementation of PV sources was proposed. Based on the results of measurements from BMS systems dozens of office buildings models for average daily electricity consumption were developed. The model was compared with the electricity production profile from the PV system to show the benefits of implementation. The article covers technical and economic aspects as the implementation of the analysis of the quality of electricity for public buildings.
21 April 2026 in IEEE Transactions on Applied Superconductivity
For precise angular characterization of high temperature superconducting (HTS) tapes, creating a stable and uniform magnetic field that allowsfull 360° sample rotation poses specific design and implementationchallenges. This work introduces a compact cylindrical Halbach array composed of permanent magnets, designetto generate a uniform magnetic flux density up to 350 mT. The system is dedicated to angular dependent measurements of the critical current lc in HTS tapes. The Halbach configuration was optimized using finite element method (FEM) simulations to maximize field uniformity in the measurement region. The experimental setup was fabricated usingadditive manufacturing and integrates the Halbach array with a four probe measurement system operating at 77 K. The mechanical design ensures precise, continuous rotation of the superconducting sample within a cryogenic environment without degrading field symmetry. Angular dependence of lc was experimentally characterized and compared with results obtained using conventional solenoidal magnets and established analytical models. The results confirm that the Halbach array provides sufficient magnetic field uniformityfor reliable lc (θ) determination while significantly reducing system cost, power demand, and cooling complexity. The maximum field of approximately 0.35 T limits the applicability of the device to low- and moderate-field measurements, making it particularly suitable for laboratory scale testing and industrial quality control of HTS conductors
21 October 2026 in Proceedings of the Estonian Academy of Sciences
Rapid prototyping of magnetic inductors requires the evaluation of inductance over a wide range of turn counts and operating currents. This task becomes computationally or experimentally demanding when nonlinear magnetic materials are considered because each candidate design may require iterative solution of the magnetic circuit model or repeated evaluations. This paper proposes a sparse-sensing framework for reconstructing inductance curves using a small number of strategically selected turn counts. A reduced basis is constructed by singular value decomposition (SVD), and informative sensing turn counts are selected by QR decomposition with column pivoting. The resulting model reconstructs the full inductanceâturn relationship from only a few evaluations. The method is demonstrated using simulated nonlinear toroidal inductor data and then incorporated into a multi-objective design workflow to select candidate cores from a commercial database. The results show that five selected turn counts are sufficient to reconstruct the inductance curve with a relative error below 0.1% in the validation cases under consideration. Combined with the non-dominated sorting genetic algorithm II (NSGA-II) optimization, the reduced model enables rapid screening of feasible core, material, and stacking configurations while preserving accuracy sufficient for engineering design.
This paper introduces the integration of smart appliances and Internet of Things technologies for the local balancing of low-voltage power distribution networks, particularly in response to the proliferation of prosumer renewable energy sources. The primary objective is the incorporation of the Elastic Energy Management algorithm with Mixed Reality and Augmented Reality interfaces to facilitate intuitive demand-side management. The methodology employs the GRASP heuristic algorithm alongside advanced on-device 3D point cloud segmentation, enabling the system to identify physical energy consumers within a residential environment. Simulation results demonstrate high algorithmic convergence and the capacity for the system to provide real-time updates to visual interfaces. The findings indicate that the utilization of AR and MR goggles significantly enhances interaction with energy infrastructure by providing hands-free operation and overlaying digital data directly onto physical components. This approach enables more effective grid balancing and increased self-consumption of renewable energy while maintaining user comfort and reducing the technical knowledge required for efficient household energy management.
The results of measurements of critical currents in HTS superconducting tapes located in a magnetic field originating from permanent magnets are presented in the paper. In order to strengthen the magnetic flux, the magnets were arranged in a linear Halbach array. As a part of the study, the effect of magnetic flux density on the value of critical currents in first (1G) and second (2G) generation of superconducting tapes has been analyzed. The presented analysis is the basis for the development of a superconducting linear motor and is aimed at testing of HTS strips exposed for a conditions corresponding to the conditions prevailing in PM HTS linear motors.