Christer Sinderby

Dr. Christer Sinderby


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2007 in Chest
Verified
Journal Article
Closed access
CSChrister Sinderby
Christer Sinderby
JBJennifer Beck
Jennifer Beck
JSJadranka Spahija
Jadranka Spahija
MMMichel de Marchie
Michel de Marchie
JLJacques Lacroix
Jacques Lacroix
ASArthur S. Slutsky
Arthur S. Slutsky

16 October 2013 in Critical Care
Verified
Journal Article
Open access
PDF file
CSChrister Sinderby
Christer Sinderby
SLSongqiap Liu
Songqiap Liu
DCDavide Colombo
Davide Colombo
GCGianmaria Cammarota
Gianmaria Cammarota
ASArthur S. Slutsky
Arthur S. Slutsky
JBJennifer C. Beck
Jennifer C. Beck
Introduction: The aim of this study was to validate an automated, objective and standardized algorithm for quantifying and displaying patient-ventilator interaction. Methods: Using a new method to detect patient-ventilator synchrony, the present study re-analyzed previously acquired and published data from 24 mechanically ventilated adult patients (Colombo et al., Crit Care Med. 2011 Nov;39(11):2452–7). Patient-ventilator interactions were evaluated by comparing ventilator pressure and diaphragm electrical activity (EAdi) waveforms, recorded during pressure support ventilation. The EAdi and ventilator pressure waveforms were analyzed for their timings (manually and automatically determined), and the error between the two waveforms was quantified. A new index of patient-ventilator interaction (NeuroSync index), which is standardized and automated, was validated and compared to manual analysis and previously published indices of asynchrony. Results: The comparison of manual and automated detection methods produced high test-retest and inter-rater reliability (Intraclass correlation coefficient = 0.95). The NeuroSync index increased the sensitivity of detecting dyssynchronies, compared to previously published indices, which were found to only detect asynchronies. Conclusion: The present study introduces an automated method and the NeuroSync index to determine patient-ventilator interaction with a more sensitive analysis method than those previously described. A dashboard-style of graphical display allows a rapid overview of patient-ventilator interaction and breathing pattern at the bedside.

31 July 2012 in Critical Care
Verified
Journal Article
Open access
PDF file
LLLing Liu
Ling Liu
HLHuogen Liu
Huogen Liu
YYYi Yang
Yi Yang
YHYingzi Huang
Yingzi Huang
SLSongqiao Liu
Songqiao Liu
HQhaibo QIU
haibo QIU
Introduction: Based on the hypothesis that failure of weaning from mechanical ventilation is caused by respiratory demand exceeding the capacity of the respiratory muscles, we evaluated whether extubation failure could be characterized by increased respiratory drive and impaired efficiency to generate inspiratory pressure and ventilation. Methods: Airway pressure, flow, volume, breathing frequency, and diaphragm electrical activity were measured in a heterogeneous group of patients deemed ready for a spontaneous breathing trial. Efficiency to convert neuromuscular activity into inspiratory pressure was calculated as the ratio of negative airway pressure and diaphragm electrical activity during an inspiratory occlusion. Efficiency to convert neuromuscular activity into volume was calculated as the ratio of the tidal volume to diaphragm electrical activity. All variables were obtained during a 30-minute spontaneous breathing trial on continuous positive airway pressure (CPAP) of 5 cm H2O and compared between patients for whom extubation succeeded with those for whom either the spontaneous breathing trial failed or for those who passed, but then the extubation failed. Results: Of 52 patients enrolled in the study, 35 (67.3%) were successfully extubated, and 17 (32.7%) were not. Patients for whom it failed had higher diaphragm electrical activity (48%; P < 0.001) and a lower efficiency to convert neuromuscular activity into inspiratory pressure and tidal volume (40% (P < 0.001) and 53% (P < 0.001)), respectively. Neuroventilatory efficiency demonstrated the greatest predictability for weaning success. Conclusions: This study shows that a mixed group of critically ill patients for whom weaning fails have increased neural respiratory drive and impaired ability to convert neuromuscular activity into tidal ventilation, in part because of diaphragm weakness. Trial Registration: Clinicaltrials.gov identifier NCT01065428. ©2012 Liu et al.; licensee BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

15 April 2017 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
JDJonne Doorduin
Jonne Doorduin
JNJoeke L. Nollet
Joeke L. Nollet
LRLisanne Roesthuis
Lisanne Roesthuis
HHHieronymus van Hees
Hieronymus van Hees
LBLaurent J. Brochard
Laurent J. Brochard
LHLeo M. A. Heunks
Leo M. A. Heunks
Rationale: Controlled mechanical ventilation is used to deliver lung-protective ventilation in patients with acute respiratory distress syndrome. Despite recognized benefits, such as preserved diaphragm activity, partial support ventilation modes may be incompatible with lung-protective ventilation due to high Vt and high transpulmonary pressure. As an alternative to high-dose sedatives and controlled mechanical ventilation, pharmacologically induced neuromechanical uncoupling of the diaphragm should facilitate lung-protective ventilation under partial support modes. Objectives: To investigate whether partial neuromuscular blockade can facilitate lung-protective ventilation while maintaining diaphragm activity under partial ventilatory support. Methods: In a proof-of-concept study, we enrolled 10 patients with lung injury and a Vt greater than 8 ml/kg under pressure support ventilation (PSV) and under sedation. After baseline measurements, rocuronium administration was titrated to a target Vt of 6 ml/kg during neurally adjusted ventilatory assist (NAVA). Thereafter, patients were ventilated in PSV and NAVA under continuous rocuronium infusion for 2 hours. Respiratory parameters, hemodynamic parameters, and blood gas values were measured. Measurements and Main Results: Rocuronium titration resulted in significant declines of Vt (mean ± SEM, 9.3 ± 0.6 to 5.6 ± 0.2 ml/kg; P < 0.0001), transpulmonary pressure (26.7 ± 2.5 to 10.7 ± 1.2 cm H2O; P < 0.0001), and diaphragm electrical activity (17.4 ± 2.3 to 4.5 ± 0.7 μV; P < 0.0001), and could be maintained under continuous rocuronium infusion. During titration, pH decreased (7.42 ± 0.02 to 7.35 ± 0.02; P < 0.0001), and mean arterial blood pressure increased (84 ± 6 to 99 ± 6 mm Hg; P = 0.0004), as did heart rate (83 ± 7 to 93 ± 8 beats/min; P = 0.0004). Conclusions: Partial neuromuscular blockade facilitates lung-protective ventilation during partial ventilatory support, while maintaining diaphragm activity, in sedated patients with lung injury.

27 September 2018 in Critical Care
Verified
Journal Article
Open access
PDF file
DJDiana Jansen
Diana Jansen
AJAnnemijn H. Jonkman
Annemijn H. Jonkman
LRLisanne Roesthuis
Lisanne Roesthuis
SGSuvarna Gadgil
Suvarna Gadgil
JHJohannes G. van der Hoeven
Johannes G. van der Hoeven
LHLeo M. A. Heunks
Leo M. A. Heunks
Diaphragm dysfunction develops frequently in ventilated intensive care unit (ICU) patients. Both disuse atrophy (ventilator over-assist) and high respiratory muscle effort (ventilator under-assist) seem to be involved. A strong rationale exists to monitor diaphragm effort and titrate support to maintain respiratory muscle activity within physiological limits. Diaphragm electromyography is used to quantify breathing effort and has been correlated with transdiaphragmatic pressure and esophageal pressure. The neuromuscular efficiency index (NME) can be used to estimate inspiratory effort, however its repeatability has not been investigated yet. Our goal is to evaluate NME repeatability during an end-expiratory occlusion (NMEoccl) and its use to estimate the pressure generated by the inspiratory muscles (Pmus). This is a prospective cohort study, performed in a medical-surgical ICU. A total of 31 adult patients were included, all ventilated in neurally adjusted ventilator assist (NAVA) mode with an electrical activity of the diaphragm (EAdi) catheter in situ. At four time points within 72 h five repeated end-expiratory occlusion maneuvers were performed. NMEoccl was calculated by delta airway pressure (ΔPaw)/ΔEAdi and was used to estimate Pmus. The repeatability coefficient (RC) was calculated to investigate the NMEoccl variability. A total number of 459 maneuvers were obtained. At time T = 0 mean NMEoccl was 1.22 ± 0.86 cmH2O/μV with a RC of 82.6%. This implies that when NMEoccl is 1.22 cmH2O/μV, it is expected with a probability of 95% that the subsequent measured NMEoccl will be between 2.22 and 0.22 cmH2O/μV. Additional EAdi waveform analysis to correct for non-physiological appearing waveforms, did not improve NMEoccl variability. Selecting three out of five occlusions with the lowest variability reduced the RC to 29.8%. Repeated measurements of NMEoccl exhibit high variability, limiting the ability of a single NMEoccl maneuver to estimate neuromuscular efficiency and therefore the pressure generated by the inspiratory muscles based on EAdi.

13 October 2014 in Critical Care
Verified
Journal Article
Open access
PDF file
JDJonne Doorduin
Jonne Doorduin
CSChrister Sinderby
Christer Sinderby
JBJennifer C. Beck
Jennifer C. Beck
JHJohannes G van der Hoeven
Johannes G van der Hoeven
LHLeo Ma Heunks
Leo Ma Heunks
Delivering synchronous assist during non-invasive ventilation (NIV) is challenging with flow- or pressure-controlled ventilators, especially in patients with chronic obstructive pulmonary disease (COPD). Neurally adjusted ventilatory assist (NAVA) uses diaphragm electrical activity (EAdi) to control the ventilator. We evaluated patient-ventilator interaction in patients with COPD during NIV with pressure support ventilation (PSV) and NAVA using a recently introduced automated analysis. Twelve COPD patients underwent three 30-minute trials: 1) PSV with dedicated NIV ventilator (NIV-PSVVision), 2) PSV with intensive care unit (ICU) ventilator (NIV-PSVServo-I), and 3) with NIV-NAVA. EAdi, flow, and airway pressure were recorded. Patient-ventilator interaction was evaluated by comparing airway pressure and EAdi waveforms with automated computer algorithms. The NeuroSync index was calculated as the percentage of timing errors between airway pressure and EAdi. The NeuroSync index was higher (larger error) for NIV-PSVVision (24 (IQR 15 to 30) %) and NIV-PSVServo-I (21 (IQR 15 to 26) %) compared to NIV-NAVA (5 (IQR 4 to 7) %; P <0.001). Wasted efforts, trigger delays and cycling-off errors were less with NAVA (P <0.05 for all). The NeuroSync index and the number of wasted efforts were strongly correlated (r2 = 0.84), with a drastic increase in wasted efforts after timing errors reach 20%. In COPD patients, non-invasive NAVA improves patient-ventilator interaction compared to PSV, delivered either by a dedicated or ICU ventilator. The automated analysis of patient-ventilator interaction allowed for an objective detection of patient-ventilator interaction during NIV. In addition, we found that progressive mismatch between neural effort and pneumatic timing is associated with wasted efforts.