Didier Defez

Mr. Didier Defez


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2020 in Biomedicine & Pharmacotherapy
Verified
Journal Article
Open access
ASAndrea Skanjeti
Andrea Skanjeti
NMNicolas Magand
Nicolas Magand
DDDidier Defez
Didier Defez
JTJeremie Tordo
Jeremie Tordo
ARAgnes Rode
Agnes Rode
Francesco GiammarileFrancesco Giammarile
Francesco Giammarile
Selective Internal Radiation Therapy (SIRT) is used for the treatment of hepatic tumors. The aim of this retrospective study was to compare two dosimetric approaches based on 99mTc-MAA SPECT/CT and 90Y PET/CT, using Simplicit90Y™ versus the supplier suggested method of activity calculation. A total of 19 patients underwent 21 SIRT after baseline angiography and 99mTc-MAA SPECT/CT, followed by 90Y PET/CT. Overlap between 99mTc-MAA and 90Y-microspheres was quantified with different thresholds isocontours. The perfused volume and tumor absorbed dose were estimated using Simplicit90Y™ based on SPECT/CT and PET/CT, then compared with the supplier suggested method. These data were related to overall survival to evaluate their prognostic impact. The overlap between PET/CT and SPECT/CT was dependent on thresholds, decreasing with an increasing threshold. The overlap between the 99mTc-MAA and 90Y-microspheres biodistributions versus the tumor distribution on morphological imaging was suboptimal, in particular for small tumor volume. The tumor absorbed dose estimated after 90Y PET/CT was not different from tumor absorbed dose estimated after SPECT/CT. The Perfused lobe absorbed dose was significantly lower while the volume of the perfused lobe was significantly higher when estimated by Simplicit90Y™ compared to the supplier suggested conventional approach. A statistical parameter based on overlap between tumor and 90Y-microspheres distribution as well as tumoral dosimetry was significantly related to the overall survival. Post-treatment imaging remains paramount to estimate the irradiation dosimetry, due to an imperfect overlap. The perfused volume could be estimated from functional imaging, given its impact on dosimetry. Finally, survival seems related to tumoral overlap and dosimetry.

Verified
Journal Article
Open access
PDF file
BCBastien Chalamet
Bastien Chalamet
JPJean Baptiste Pialat
Jean Baptiste Pialat
AVAnthony Viste
Anthony Viste
DDDidier Defez
Didier Defez
PBPierre-Adrien Bolze
Pierre-Adrien Bolze
NSNicolas Stacoffe
Nicolas Stacoffe
Objectives: Management of unstable pelvic fractures during pregnancy presents a major therapeutic challenge, requiring careful multidisciplinary evaluation to balance maternal benefits and fetal radiation risks. Methods: We report the case of a 32-year-old patient who presented with a pelvic fracture due to a road traffic accident at three months of pregnancy. A left sacroiliac osteosynthesis was performed to treat a left sacroiliac diastasis with pelvic osteosynthesis using a trans-iliosacral approach under cone-beam CT (CBCT) guidance using a very-low-dose protocol. Radiation parameters and fetal dose estimates were calculated in advance in collaboration with a medical physicist. Tight beam collimation, a reduced field of view, and minimization of fluoroscopic checks were applied to keep fetal exposure as low as reasonably achievable. This article aims to demonstrate the feasibility of managing a complex pelvic fracture using interventional radiology and to review the literature on management options and gestational age-dependent fetal risks. Results: The estimated cumulative fetal dose from initial imaging, open surgery, and CBCT-guided osteosynthesis remained below 70 mGy using a pregnant phantom (Duke Organ Dose–Dosewatch–General Electric system), which is below thresholds associated with deterministic effects. The procedure achieved optimal screw positioning with less than 40 s of fluoroscopy. Maternal postoperative recovery was favorable, and follow-up revealed normal fetal development. Conclusions: This case demonstrates that CBCT-guided percutaneous iliosacral screw fixation can be safely performed during pregnancy with meticulous planning, dose-reduction strategies, and multidisciplinary collaboration, maintaining fetal radiation exposure below accepted safety thresholds.