Gabriele Chinello

Dr. Gabriele Chinello

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2024 in Flow Measurement and Instrumentation
Verified
Journal Article
Open access
RBRussell Brown
Russell Brown
GCGabriele Chinello
Gabriele Chinello
MWMarcel Workamp
Marcel Workamp
BMBodo Mickan
Bodo Mickan


24 March 2026 in Metrology
Verified
Journal Article
Open access
PDF file
AAAra Abdulrahman
Ara Abdulrahman
GCGabriele Chinello
Gabriele Chinello
RSRevata Seneviratne
Revata Seneviratne
KRKurt Rasmussen
Kurt Rasmussen
DPDennis van Putten
Dennis van Putten
PSPier Giorgio Spazzini
Pier Giorgio Spazzini
Carbon capture, utilization, and storage (CCUS) plays an important role in meeting the European Union’s target to reduce greenhouse gas emissions by 55% by 2030 and become carbon neutral by 2050. Accurate flow metering is required throughout the carbon capture and storage (CCS) chain to meet fiscal and regulatory requirements. To establish accurate CO2 flow metering, flow meters must be calibrated with traceability to international standards of measurement at relevant flow conditions. To ensure confidence, reliability, and comparability of calibration results, calibration facilities perform interlaboratory comparisons. However, there is currently a lack of CO2 gas flow meter calibration facilities. The flow metering calibration facilities of VSL, NEL, INRIM, DNV, and FORCE participated in an interlaboratory comparison with CO2 up to 400 m3/h and 31 bar(a) to compare the calibration results with several flow metering principles. At the intermediate-scale facilities of NEL, VSL, and INRIM, the difference in results between the VSL and INRIM facilities were within the facilities’ CMC values, while NEL’s facility showed a significant difference primarily due to vibrational relaxational effects of CO2 with small critical flow Venturi nozzles. At the large-scale facilities of NEL, DNV, and FORCE, 91% of the test points passed the equivalency criteria in the range of 20 m3/h to 400 m3/h with a Coriolis meter, confirming traceability for carbon dioxide across the facilities. Overall, the interlaboratory comparison has made it possible for the CCUS industry to calibrate gaseous CO2 flow meters with traceability to international standards.

1 February 2026 in Measurement
Verified
Journal Article
Open access
SHSeyedahmad Hosseini
Seyedahmad Hosseini
GCGabriele Chinello
Gabriele Chinello
GLGordon Lindsay
Gordon Lindsay
Don McGlincheyDon McGlinchey
Don McGlinchey

26 November 2025 in Flow Measurement and Instrumentation
Verified
Journal Article
Closed access
SHSeyedahmad Hosseini
Seyedahmad Hosseini
GCGabriele Chinello
Gabriele Chinello
GLGordon Lindsay
Gordon Lindsay
ELErfan Loweimi
Erfan Loweimi
MAMuhammad Ayub Ansari
Muhammad Ayub Ansari
DMDon McGlinchey
Don McGlinchey