In this work, an algorithm was developed to measure respiration rate for an embedded device that can be used by a field robot for relief operations. With this algorithm, the rate measurement was calculated based on direct influences of respiratory-induced intensity variation (RIIV) on blood flow in cardiovascular pathways. For this, a photoplethysmogram (PPG) sensor was used to determine changes in heartbeat frequencies. The PPG sensor readings were filtered using an Information Filter and a fast Fourier transform (FFT) to determine the state of RIIV. With a relatively light initialization, the information filter can estimate unknown variables based on a series of measurements containing noise and other inaccuracies. Therefore, this filter is suitable for application in an embedded device. For faster calculation time in the implementation, the FFT analysis was calculated only for a major peak in frequency domain. Test and measurement of respiration rate was conducted based on the device algorithm and spirometer. Heartbeat measurements were also evaluated by comparing the heartbeat data of the PPG sensor and pulse-oximeter. Based on the test, the implemented algorithm can measure the respiration rate with approximately 80% accuracy compared with the spirometer.

8 August 2018 in Preprints.org
Verified
Preprint
Open access
PDF file
RPRadius Prasetiyo
Radius Prasetiyo
KCKyu-Sang Choi
Kyu-Sang Choi
GYGi-Hun Yang
Gi-Hun Yang
In this work, an algorithm was developed to measure the respiration rate for an embedded device that can be used by a field robot for relief operation. With this algorithm, the rate measurement was calculated based on direct influences of respiratory-induced intensity variation (RIIV) on blood flow in cardiovascular pathways. For that, a photoplethysmogram (PPG) sensor was used to determine changes in heartbeat frequencies. The PPG sensor readings were filtered using an Information Filter and a Fast Fourier transform (FFT) to determine the state of RIIV. With a relatively light initialization, the information filter can estimate unknown variables based on a series of measurements containing noise and other inaccuraties. Therefore, this filter is suitable for application on an embedded device. For faster calculation time in the implementation, the FFT analysis was calculated only for a major peak in the frequency domain. Test and measurement of respiration rate was conducted based on the device algorithm and spirometer. Heartbeat measurement was also evaluated by comparing the heartbeat data of the PPG sensor and the medical tool kit. Based on the test, the implemented algorithm can measure respiration rate with about 80% accuracy compared with the spirometer.