Xinghua Qu

Xinghua Qu


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JWJin-dong Wang
Jin-dong Wang
JJJiajia Jiang
Jiajia Jiang
FDFajie Duan
Fajie Duan
Fumin ZhangFumin Zhang
Fumin Zhang
Wei LiuWei Liu
Wei Liu
XQXinghua Qu
Xinghua Qu
For ultrasonic systems, the resonance frequency tracking (RFT) is the most critical step. The rapid development in advanced material processing and microelectronics package has increased the demand of high speed RFT. Therefore, this paper proposes a fast RFT (FRFT) method according to the characteristics of piezoelectric transducers' (PT) admittance circle. In the proposed method, the PT is driven at two different frequencies, and the PT's admittance is collected and calibrated. Then, the PT's mechanical resonance frequency is derived using the admittance information after calibration. The proposed method is not affected by the parallel capacitor and the matching circuit. Additionally, the optimal initial values of the involved parameters are determined in order to improve the accuracy of the proposed method. Furthermore, an improved method based on multiple tracking is also provided. Simulations and experiments demonstrate that using the proposed FRFT method, the ultrasonic system can track the resonance frequency in a short time with high accuracy.

2 April 2015 in Sensors
Verified
Journal Article
Open access
PDF file
BLBailing Liu
Bailing Liu
Fumin ZhangFumin Zhang
Fumin Zhang
XQXinghua Qu
Xinghua Qu
An improvement method for the pose accuracy of a robot manipulator by using a multiple-sensor combination measuring system (MCMS) is presented. It is composed of a visual sensor, an angle sensor and a series robot. The visual sensor is utilized to measure the position of the manipulator in real time, and the angle sensor is rigidly attached to the manipulator to obtain its orientation. Due to the higher accuracy of the multi-sensor, two efficient data fusion approaches, the Kalman filter (KF) and multi-sensor optimal information fusion algorithm (MOIFA), are used to fuse the position and orientation of the manipulator. The simulation and experimental results show that the pose accuracy of the robot manipulator is improved dramatically by 38%~78% with the multi-sensor data fusion. Comparing with reported pose accuracy improvement methods, the primary advantage of this method is that it does not require the complex solution of the kinematics parameter equations, increase of the motion constraints and the complicated procedures of the traditional vision-based methods. It makes the robot processing more autonomous and accurate. To improve the reliability and accuracy of the pose measurements of MCMS, the visual sensor repeatability is experimentally studied. An optimal range of 1 x 0.8 x 1 ~ 2 x 0.8 x 1 m in the field of view (FOV) is indicated by the experimental results.

17 June 2015 in Sensors
Verified
Journal Article
Open access
PDF file
ZCZhe Chen
Zhe Chen
Fumin ZhangFumin Zhang
Fumin Zhang
XQXinghua Qu
Xinghua Qu
BLBaoqiu Liang
Baoqiu Liang
In this paper, we propose a new approach for the measurement and reconstruction of large workpieces with freeform surfaces. The system consists of a handheld laser scanning sensor and a position sensor. The laser scanning sensor is used to acquire the surface and geometry information, and the position sensor is utilized to unify the scanning sensors into a global coordinate system. The measurement process includes data collection, multi-sensor data fusion and surface reconstruction. With the multi-sensor data fusion, errors accumulated during the image alignment and registration process are minimized, and the measuring precision is significantly improved. After the dense accurate acquisition of the three-dimensional (3-D) coordinates, the surface is reconstructed using a commercial software piece, based on the Non-Uniform Rational B-Splines (NURBS) surface. The system has been evaluated, both qualitatively and quantitatively, using reference measurements provided by a commercial laser scanning sensor. The method has been applied for the reconstruction of a large gear rim and the accuracy is up to 0.0963 mm. The results prove that this new combined method is promising for measuring and reconstructing the large-scale objects with complex surface geometry. Compared with reported methods of large-scale shape measurement, it owns high freedom in motion, high precision and high measurement speed in a wide measurement range.

3 January 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Fumin ZhangFumin Zhang
Fumin Zhang
YLYa-Ting Li
Ya-Ting Li
HPHao Pan
Hao Pan
CSChun-Zhao Shi
Chun-Zhao Shi
XQXinghua Qu
Xinghua Qu
The frequency-scanning-interferometry-based (FSI-based) absolute ranging technology is a type of ranging technology possessing a high precision and no ranging blind area, so it can be used for non-cooperative targets. However, due to a tiny movement of a target, the Doppler shift and the phase modulation are introduced into the beat signal which results in ranging accuracy decrease. In order to solve this problem, first the model of vibration effect is established, and then the beat signals of two adjacent scanning periods are processed to produce a signal that is immune to vibration. The proposed method is verified by the experiments, and the experimental results show that the effect of vibration compensation is better for the target with a lower vibration velocity and at a lower vibration frequency (lower than 6 Hz). When the target is subjected to a sinusoidal vibration with an amplitude of 10 μm at a frequency of 1 Hz, by using the proposed method the standard deviation is reduced from 775 to 12 μm. Moreover, in the natural environment, by using vibration compensation the standard deviation is reduced from 289 to 11 μm.

4 May 2012 in Sensors
Verified
Journal Article
Open access
PDF file
Fumin ZhangFumin Zhang
Fumin Zhang
XQXinghua Qu
Xinghua Qu
JOJianfei Ouyang
Jianfei Ouyang
A novel measurement prototype based on a mobile vehicle that carries a laser scanning sensor is proposed. The prototype is intended for the automated measurement of the interior 3D geometry of large-diameter long-stepped pipes. The laser displacement sensor, which has a small measurement range, is mounted on an extended arm of known length. It is scanned to improve the measurement accuracy for large-sized pipes. A fixing mechanism based on two sections is designed to ensure that the stepped pipe is concentric with the axis of rotation of the system. Data are acquired in a cylindrical coordinate system and fitted in a circle to determine diameter. Systematic errors covering arm length, tilt, and offset errors are analyzed and calibrated. The proposed system is applied to sample parts and the results are discussed to verify its effectiveness. This technique measures a diameter of 600 mm with an uncertainty of 0.02 mm at a 95% confidence probability. A repeatability test is performed to examine precision, which is 1.1 µm. A laser tracker is used to verify the measurement accuracy of the system, which is evaluated as 9 µm within a diameter of 600 mm.

7 December 2009 in Optics Letters
Verified
Journal Article
Closed access
PDF file
XQXinghua Qu
Xinghua Qu
LWLi-Hua Wang
Li-Hua Wang
YFYun-Xia Fu
Yun-Xia Fu
A common-path laser interferometer is introduced. Its most important feature is that two optical arms are entirely in a common path. Laser Doppler and laser polarization interference technologies are used in the proposed optical system. An experiment setup is established. The primary experimental result shows that this common path method is very feasible. The resolution is 0.72 nm within a 0.01 mm range, and the highest velocity is 0.56 mm/s. There is much room to improve its performance.