Wang Conrong

Dr. Wang Conrong


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2017 in Teaching in Higher Education
Verified
Journal Article
Closed access
WCWang Conrong
Wang Conrong
KHKuo Hung Huang
Kuo Hung Huang
This paper investigates the prominence of rationalism in the major Western pedagogical theories of Plato, Rousseau, and Dewey, all of whom conceptualize formal teaching, as the inculcation of rationality in individual learners. After each of their theories has been described, the argument turns against the tradition of pedagogical rationalism to question what happens in the education of artists, quasi-artists, and creative designers. The answer given is that imagination must be paramount and strongly encouraged in the education of such students, despite the problematic fact that imagination – seeing the truth – cannot be taught the way that rationality can, relying instead on the analysis of successful works of art and design as exemplary and allowing students to freely pursue their own individual inspirations.

1 February 2010 in Renewable Energy
Verified
Journal Article
Closed access
WCWang Conrong
Wang Conrong
SLShih Yuan Liu
Shih Yuan Liu

27 November 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
YLYongze Li
Yongze Li
HXHongpeng Xu
Hongpeng Xu
JWJianmei Wu
Jianmei Wu
ZLZhang Lei
Zhang Lei
TJTeng Jiajia
Teng Jiajia
LMLin MaoJian
Lin MaoJian
It is a common phenomenon that the stairs of modern historical brick and wood buildings can not meet the existing fire protection specifications, which has become a difficulty in the repair. Based on this, this paper proposes two different repair strategies for the Chinese Baroque "Hui" shaped building in Harbin, and uses the computer fire evacuation performance simulation as the method to explore the influence of the changes of stair width, number, location and building size on the safety movement duration and number of individuals who failed to evacuate in the two repair strategies, and compares the effectiveness of common fire prevention measures. It is found that the fire development laws of the two building repair methods are similar when corre-sponding to the same stair state and building volume; When the width of stairs in-creased from 900mm to 1100mm, the evacuation effect was not significantly improved; Increasing the number of existing interior staircases from one to two increases the proportion of safely evacuated occupants from 68% to 91%.; The exterior corridor staircase shows the highest evacuation efficiency, with a single staircase sufficient to ensure the safe evacuation of all occupants; Given the same increment in total area, the increase in evacuation movement time caused by adding stories is approximately twice that caused by expanding the building footprint.; The fire prevention effect of automatic sprinkler and mechanical smoke exhaust is more obvious.

28 January 2026 in Buildings
Verified
Journal Article
Open access
PDF file
YLYongze Li
Yongze Li
JWJianmei Wu
Jianmei Wu
LZLei Zhang
Lei Zhang
JTJiajia Teng
Jiajia Teng
XLXiaodan Liu
Xiaodan Liu
JMJianlin Mao
Jianlin Mao
It is a common phenomenon that the stairs of modern historical brick–timber buildings cannot meet existing fire protection specifications, something which has become a difficulty in their renovation. In response, this study proposes two different renovation strategies for the Hui-shaped Chinese Baroque brick–timber building in Harbin and constructs multiple fire scenarios. Using a coupled PyroSim–Pathfinder (version 2023.2.0816) simulation approach, a finite element model of the building under fire and a corresponding evacuation model are established. The aim is to investigate how variations in stair width, number, position, and overall building scale under the two renovation strategies influence evacuation movement time and the number of evacuation failures, and to compare the effectiveness of common fire protection measures. The results show that, for the same stair configuration and building mass, the fire development patterns of the two renovation strategies are similar. Increasing the stair width from the original 0.9 m to 1.1 m produces no significant improvement in evacuation performance. When the number of indoor existing stairways increases from one to two, the proportion of occupants evacuated safely rises from 68% to 91%. External corridor staircases provide the best evacuation performance, and a single such stair can satisfy the safe evacuation of all occupants. When the same additional floor area is provided, increasing the number of storeys extends the evacuation movement time by approximately twice that caused by increasing the building footprint. Automatic sprinkler systems and mechanical smoke exhaust systems exhibit more pronounced fire protection effects.

22 January 2021 in Research Square
Verified
Preprint
Open access
PDF file
CZChaoYang Zhang
ChaoYang Zhang
WCWang Conrong
Wang Conrong
Background: Sustainable development is a global trend, prompting the development of green school buildings. Green building and low-carbon campus promotion in junior high schools and elementary schools were researched in this study to facilitate improved environmental protection, energy saving, and carbon reduction as well as the construction of green, low-carbon campuses. Methods: A review of green building certification approvals was used to establish a green campus assessment system with suitable sustainability factors. Relevant indicators were constructed using the Fuzzy Delphi Method and the Analytic Hierarchy Process. Questionnaires were administered to various types of experts regarding the decision sequence for constructing a green, low-carbon campus in junior high schools and elementary schools. Results: The decision most highly prioritized by all experts was related to lifestyle education and policy management. A healthy campus environment was assigned second place. Energy- and carbon-saving planning and the ecoenvironment were ranked lower. The results provide a reference for architectural planning and implementation, for schools, and for researchers. Conclusion: The government can use them to inform appropriate policies and to establish priorities and indicator weights for promoting green, low-carbon school campuses. Education resources can thereby be reasonably allocated, green building quality on campuses enhanced, and energy-saving and carbon-saving measures implemented.